BRESSER 7004360 RC Weather Station ClimateTemp Instruction Manual

July 3, 2024
BRESSER

BRESSER 7004360 RC Weather Station ClimateTemp

Specifications

  • Product Name: RC Weather station ClimateTemp NDV-NEO
  • Model Number: 7004360
  • Language Options: EN, DE, FR, SP, IT, DU, DA

Product Information
The RC Weather station ClimateTemp NDV-NEO is a wireless weather station that provides information on temperature, barometric pressure trends, temperature alarms, calendar, time with DCF synchronization, DST (Daylight Saving Time) settings, alarm clock snooze function, and frost warnings.

Usage Instructions
General Informatio n
Refer to the manual for detailed instructions in multiple languages.

Setup:
Base Station:

  1. Connect the power adapter to the base station.
  2. Wait for the indoor temperature to display on the base station.

FAQ
Q: How can I change the language settings on the weather station?
A: Language settings can be adjusted by following the manual instructions for language selection.

Validity note

This documentation is valid for the products with the following article numbers:
7004360
Manual version: 0324

Manual designation:
Manual_7004360_RC-WeatherStation-ClimateTemp_ND-V-NEO_de-en-fr-nl-es- it_BRESSER_v032024a
Always provide information when requesting service.

General Information

About this Instruction Manual
These operating instructions are to be considered a component of the device.
Read the safety instructions and the instruction manual carefully before using this device.
Keep these instruction manuals in a safe place for future reference. If the device is sold or passed on, the instruction manual must be passed on to any subsequent owner/user of the product.

DANGER!
You will find this symbol before every section of text that deals with the risk of minor to severe injuries resulting from improper use.

ATTENTION!
You will find this symbol in front of every section of text which deals with the risk of damage to property or the environment.

 General Warnings

DANGER!
This device contains electronic components which operate via a power source (power supply and/or batteries). Only use the device as described in the manual, or you run the risk of an electric shock.
Keep batteries out of the reach of children! Make sure you insert the batteries correctly. Empty or damaged batteries could cause burns if they come into contact with the skin. If necessary, wear adequate gloves for protection.

ATTENTION!

Do not disassemble the device. In the event of a defect, ple-ase contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary. Do not expose the device to temperatures above 60°C.
Do not expose the device to high temperatures. Use only the supplied power supply or the recommended batteries. Do not short-circuit the device or batteries or throw them into a fire! Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion.
Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. The batteries should be removed from the unit if it has not been used for a long time.

 Scope of delivery

RC Weather station ClimateTemp NDV-NEO

Sensor 7009985
EU-UK-Adapter

Parts Overview

  1. Weather forecast (5 kinds of weather forecast: Sunny,Partly Sunny, Cloudy, Rainy, Snowy)

  2. Temperature trend arrow

  3. Barometer history

  4. Temperature alert

  5. Outdoor temperature

  6. MAX and MIN arrows

  7. Channel fl ow

  8. Outdoor symbol

  9. Channel number

  10. Outdoor humidity

  11. Indoor humidity

  12. Low battery indicator

  13. Indoor symbol

  14. Indoor temperature

  15. Barometer value

  16. Moon phase

  17. 7 languages week display (EN,DE,FR,SP,IT,DU,DA)

  18. Calendar

  19. Time with DCF

  20. DST Summertime

  21. Alarm clock

  22.  Snooze-Symbol

  23. Ice-Alert

  24. button

  25.  button

  26. button

  27. button

  28. button

  29.  button

  30. DC hole

  31. Stand

  32. Battery cover

  33. Hanging hole

  34. button (set snooze function/display brightness)
    7004360-RC-Weather-Station-ClimateTemp- \(4\)

Main Function Sensor

  • A. Temperature
  • B. Current channel
  • C. Humidity
  • D. LED INDICATOR
  • E. Wall Mount
  • F. Reset
  • G. Transmission channel (1-3)
  • H. Battery Compartment for 2x AAA

7004360-RC-Weather-Station-ClimateTemp- \(6\)

AC Power Adapter

  1. Euro plug adapter
  2. UK plug adapter
  3. Adapter fixture
  4. Locking knob
  5. DC barrel connector

Setting up power supply

Base device:

  1. Insert the DC connector into the connection socket (29) of the base station.

  2. Insert the mains plug into the power outlet.

  3. The device is energized directly.

  4. Wait until the indoor temperature is displayed on the base station.
    NOTICE! For permanent operation, mains power supply is recommended. Alternatively a power supply with batteries is also possible, to keep the time setting in case of power failure (permanent backlight not active).
    Proceed as follows:

  5. Remove the battery compartment cover.

  6. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.

  7. Replace the battery compartment cover.

  8. Wait until the indoor temperature is displayed on the base station.

NOTICE! After 7 seconds, the display switches to power-saving mode in battery mode. When using battery power, press the SNOOZE/LIGHT button to activate the display for about 7 seconds.
NOTICE! When switching from mains power supply to battery power supply or vice versa, the power supply is being disabled for a short mo-ment for technical reasons. Exception: permanent battery operation.

Remote sensor:

  1.  Remove the battery compartment cover.
  2. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
  3.  Set the channel selector switch to the desired channel.

NOTICE! This weather station can be operated with one or more remote sensors. Each remote sensor being connected must be operated on a

  1. Press and hold the button on the base unit for approx. 3 seconds to activate reception of the radio signal. Reception is now initialized again.
  2. If still no radio signal is received, the time must be set manually.

Manual time setting:

  1. Press and hold button for approx. 3 seconds to enter to the time setting mode.
  2. Digits to be set are flashing.
  3. Press or button to change the value.
  4. Press button to confirm and continue to the next setting.
  5. Settings order: Time zone>12/24H format>Hour> Minute>DM/MD> Year> Month>Day>Week language
  6. Finally press the button to save the settings and exit the setting mode.

In normal mode, press button to select the temperature unit in C or F.

Alarm setting

  1. In normal mode, press button to check the alarm time.
  2. When check the alarm time, press button again to turn on or turn off the alarm.
  3. When enter the alarm mode, press and hold the button for approx. 3 seconds to enter  the alarm setting mode. Digits to be set are flashing. Press or button to change the value. Press button to confirm and continue to the next setting.
  4. Settings order: Hour> Minute.
  5. Finally press the button to save the settings and exit the Alarm setting mode.

When the alarm sounds, press the button to activate the snooze function. The alarm sounds again after 5 minutes.
When the alarm sounds, press any other key to stop the alarm until the set alarm time is reached again.

Max / Min temperature and humidity record

  1. In normal mode, press the button to check the Max and Min temperature and humidity record.
  2. When checking the Max/Min record, press and hold the button to clear the record.

Channel select

  1. In normal mode, press the button to select Channel 1, Channel 2 , Channel 3 or cycle display.
  2.  Hold the button for approx. 3 seconds to reset values and search for an RF signal.

NOTICE! Always make sure the channel chosen on the display unit matches the channel option chosen on the outdoor sensor.

Backlight

When power on the adapter, press the has 3 levels backlight (dark, medium, light).
When power by batteries, press the button to turn on the backlight for 7 seconds .

Temperature Alert

  1. In normal mode, Press the button to turn on or turn off the temperature alert. The out-door temperature alarm is set first, then the outdoor and indoor temperature alarms, then the indoor temperature alarm.
  2. In normal model, Press and hold the button for approx. 3 seconds to enter the temperature alert setting.
  3. Press the or button to set the temperature.
  4. Press  button to confirm and continue to the next setting.
  5. Settings order: Indoor high temperature> Indoor low temperature> Outdoor high tem-perature> Outdoor low temperature
  6. In the same way, you can set temperature alar-ms for CH1-3 by selecting the desired channel with the Channel button , then setting and activating the temperature alarm.

 Ice Alert

When the outdoor temperature hits is between -1.0+2.9℃, the ice alert symbol will appear on the display, flashing continuously.
NOTICE! The main unit can connect with 3 outdo-or sensors, if one of the sensors temperature is between -1.0~+2.9℃, the main unit will show the ice alert symbol . The symbol will stop flashing when the temperature has risen above 3°C.

Weather Forecast

The temperature trend indicator shows the trends of weather change for the coming minutes. Arrows indicate a rising, stable or falling trend.
The barometer measures the air pressure every 15 minutes. Based on this measurement, the main unit calculates the air pressure for the current hour (the average air pressure of now / 15 minutes ago / 30 minutes ago / as well as 45 minutes ago) and compares this value with the value of the previous hour. If the measured air pressure has changed by more than 1 hPa, an increasing (UP) or decreasing (DOWN) trend arrow is displayed.

Weather Forecast

A weather trend for the next 12-24 hours is calculated from the measured values and displayed graphically as follows:

 Moon Phase

The phase of the moon depends on the current date. It is automatically calculated and the following symbols are displayed:

Barometer

Record and display the changing trend in a chart based on the air pressure history in the past 12 hours. The horizontal data is the 6 time periods in the past 12 hours (-12, -6, -3, -2, -1, 0), and the vertical data is the air pressure change value (the value is 0 by default when the power plugged in, each grid above or below represents 2hPa). Taking the air pressure value of the current period as the reference point, through comparison and calcula- tion, we can determine whether the air pressure in the past 6 time periods has increased or decreased. (It is flat when it is just powered on.)

Technical data

Main unit DCF
Batteries: 3x AAA Batteries (not included)

EU-UK adapter incl
Temperature measuring unit: °C / °F Temperature display range: -9.9°C – 50°C Humidity display range: RH 20% – 95%

Outdoor sensor
Batteries: 2x AAA Battery
Temperature measuring unit: °C / °F Temperature display range: -40°C – 70°C Humidity display range: RH 20% – 95%

EC Declaration of Conformity

Bresser GmbH hereby declares that the radio equipment type with item number 7004360 is in compliance with Directive 2014/53/EU. The full text of the EC Declaration of Conformity isavailable at the following web address: www.bresser.de/download/7004360/CE/7004360_CE.pdf

DISPOSAL

Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal.
Do not dispose of electronic devices in the household garbage! As per Directive 2002/96/ EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner. In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in the normal household waste is explicitly forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Directive.
Batteries that contain toxins are marked with a sign and a chemical symbol. “Cd” = cadmium, “Hg” = mercury, “Pb” = lead.

  1. battery contains cadmium
  2.  battery contains mercury
  3. battery contains lead

Warranty

The regular warranty period is 2 years and starts on the day of purchase. To benefit from an extended voluntary warranty period as indicated on the gift box, registration on our website is required. You can consult the full guarantee terms as well as information on extending the guarantee period and details of our services at www.bresser.de/warranty_terms

Please contact the service centre first for any questions regarding the product or claims, preferably by e-mail.

E-Mail: service@bresseruk.com
Telephone*: +44 1342 837 098

Bresser GmbH Gutenbergstraße 2
46414 Rhede · Germany
www.bresser.de
@BresserEurope

Bresser UK Ltd.
Suite 3G, Eden House Enterprise Way Edenbridge, Kent TN8 6HF Great Britain

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals