HEAT GLO 8K Direct Vent Gas Fireplace Instruction Manual
- June 12, 2024
- HEAT GLO
Table of Contents
8K
Direct Vent Gas Fireplace
Specifications
Scan QR code for installation manual for final dimensions and requirements.
ACTUAL
DIMENSIONS| FRONT WIDTH| HEIGHT| DEPTH| GLASS SIZE|
BTU/HOUR INPUT
---|---|---|---|---|---
48-1/16″ [1221]| 42-7/8″ [1089]| 21-7/16″ [545]| 41-1/4″ x 26-11/16″
[1048 X 678]| 19,000 – 35,000 BTUs (NG)
17,000 – 34,000 BTUs (LP)
FRAMING
DIMENSIONS| FRONT WIDTH| HEIGHT| DEPTH| WEIGHT
---|---|---|---|---
49″ [1245]| 42-1/8″ [1070]| 22″ [559]| 194 LBS [88 KGS]
COMBUSTIBLE MANTEL PROJECTIONS Note: Measurement is taken from top of the
opening, NOT the top of the fireplace.
Portrait front requires taller combustible clearances or Passive Heat; see
install manual for details.
NON-COMBUSTIBLE MANTEL PROJECTIONS Note: Measurement is taken from top of
the opening, NOT the top of the fireplace.
COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS NON-COMBUSTIBLE MANTEL LEGS
OR WALL PROJECTIONS If using heat management please refer to the fireplace
installation manual for framing guidelines and reduced mantel clearances.
Additional information on venting, TV clearances, finishing requirements,
fronts, etc can be found in the installation and owner’s manual
EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS NOTE: If overhang (A) is
less than 2 inches, clearance from top of termination cap to bottom of
overhang (B) may be 0 inches.
A – Measured from back of vent cap to end of overhang
B – Measured from bottom of overhang to top of termination cap
Vinyl Siding Shield (TRAP-VSS) Information TRAP-VSS required if overhang (A)
is greater than 3 inches but less than 5 inches and B dimension is less than
18 inches.
TRAP-VSS recommended if either of the below is true:
– Overhang (A) is less than 5 inches (to combat water infiltration)
– A vinyl overhang is present Shows center of vent framing hole for top or
rear venting. The center of the hole is one (1) in. (25 mm) above the center
of the horizontal vent pipe.
PRODUCT LISTING CODES
US| ANSI Z21.88-2019
CAN| CSA 2.33-2019
| UL307B
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
Heat & Glo — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 |
heatnglo.com HNG/8K_0623