BEGA 50 542.1 Recessed Ceiling Downlight
Product Information
Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients and other issues, separate overvoltage protection components are recommended. These components can be found on our website at www.bega.com.
Light Technical Specifications:
- Symmetrical wide beam light distribution
Lamp Module Specifications:
Module Designation| Colour Temperature| Colour Rendering Index (CRI)| Module
Luminous Flux| Luminaire Luminous Flux| Luminaire Luminous Efficiency
---|---|---|---|---|---
LED-0888/930| 3000 K| CRI > 90| 2025 lm| 1270 lm| 72.6 lm / W
LED-0888/940| 4000 K| CRI > 90| 2060 lm| 1291 lm| 73.8 lm / W
Product Usage Instructions
Installation:
- Ensure that the luminaire housing and external LED power supply unit are not covered by any heat-insulating materials.
- Avoid touching the light output opening of the LED directly during installation or relamping.
- Slide the LED unit with the opposite side of the screw cable gland onto the luminaire housing.
- Tighten the knurled screw hand-tight.
- Use the provided protective gloves to prevent fingerprints on the reflector while assembling it.
- Compress the fastening springs of the luminaire housing on both sides and slide the luminaire housing into the recessed opening.
- The fastening springs will lock into place behind the ceiling panel.
Replacing the LED module:
- Disconnect the system and open the luminaire.
- Refer to the installation instructions for the LED module and follow them carefully.
- Close the luminaire once the replacement is complete.
Application
- Recessed ceiling downlight · indoor luminaire with symmetrical wide beam light distribution and an external non-dimmable power supply unit.
- For installation in suspended ceilings of 1,5- 25 mm in interior applications.
Product Description
- Recessed LED ceiling luminaire with a remote power supply unit
- Luminaire housing made of cast aluminum
- Finish Colour white
- Reflector surface is made of pure aluminum
- Light-diffusing disc
- Fixing is achieved by using 2 fastening springs
- Recessed opening ø 166 x 166 mm
- Required installation depth 95 mm
- External LED power supply unit 220-240 V x 0/50-60 Hz
- Safety class II 2
- Safety mark
- Conformity mark
- Weight: 0.6 kg
- This product contains light sources of energy efficiency class(es) D, E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp Specification
- Module connected wattage 14 W
- Luminaire connected wattage 17.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 40 °C
50 542.1 K3
- Module designation LED-0888/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 2025 lm
- Luminaire luminous flux 1270 lm
- Luminaire luminous efficiency 72,6 lm / W
50 542.1 K4
- Module designation LED-0888/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 2060 lm
- Luminaire luminous flux 1291 lm
- Luminaire luminous efficiency 73,8 lm / W
Light technique
Symmetrical wide beam light distribution
Installation
Luminaire housing and external LED power supply unit must not be covered by any heat-insulating materials.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
- The recessed opening is covered by the frame of the luminaire housing.
- Fixing of the luminaire housing in the recessed opening is achieved by using two springs.
Installation in suspended ceilings:
- A recessed opening of 166 x 166 mm with a minimum depth of 95 mm is required.
- The lateral clearance from the installation housing to parts of the building must be at least 50 mm.
- The minimal thickness of the ceiling panel must be 1,5 mm and must not be greater than 25 mm. A ceiling panel with less than 1,5 mm thickness must be reinforced on the reverse.
- The electrical connection must be made on-site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
- Ensure the correct assignment of the connecting cable. Establish the main connection on the brown (L) and blue (N) wires.
- Guide the LED power supply unit through the opening in the ceiling and position it on the suspended ceiling.
- Slide the LED unit with the opposite side of the screw cable gland onto the luminaire housing.
- Tighten the knurled screw hand-tight.
- Please use the protective gloves provided for the installation to prevent finger prints on the reflector.
- Assemble reflector.
- Compress the fastening springs of the luminaire housing on both sides and slide the luminaire housing into the recessed opening.
- The fastening springs lock into place behind the ceiling panel.
Dimension
Cleaning And Maintenance
Clean the luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Close the luminaire.
Spares
- Knurled screw 52 001 803
- LED power supply unit DEV-0349/700
- LED module 3000 K LED-0888/930
- LED module 4000 K LED-0888/940
- Reflector 76 001 659
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.
References