Product Information
This product is a pendant luminaire designed for use in arcades, galleries, and passageways. It provides unshielded light and is suitable for both interior and exterior applications. When installed outdoors, it is important to protect the luminaire from constant pendulum movement caused by wind. The luminaire uses LED modules with a connected wattage of 45.6W and 50.2W. It has a rated temperature range of 25°C to 45°C and an ambient temperature range of 24°C to 131°C. The colour temperature options available are 3000K and 4000K. The colour rendering index (CRI) is greater than 80. The module luminous flux is 9160 lm for the 3000K option and 9400 lm for the 4000K option. The luminaire luminous flux is 8105 lm for the 3000K option and 8317 lm for the 4000K option. The luminaire luminous efficiency is 161.5 lm/W for the 3000K option and 165.7 lm/W for the 4000K option. This luminaire complies with national safety regulations, and its installation and commissioning should only be carried out by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation. If any modifications are made to the luminaire, the person responsible for these modifications is considered the manufacturer. The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. However, for additional protection against transients, it is recommended to use separate overvoltage protection components.
Product Usage Instructions
- Ensure that the installation and commissioning of the luminaire are performed by a qualified electrician in compliance with national safety regulations.
- When handling the luminaire, avoid touching the light output opening of the LED directly to prevent damage to the high-quality electronic components.
- To install the luminaire, insert the sphere into the holder plate and adjust it centrally.
- Tighten the screws at the holder plate evenly, making sure that the gasket is positioned correctly.
Dimension
Instructions for use
Application
Pendant luminaire with unshielded light for mounting in arcades, galleries and
passageways. When installed in exterior applications, the luminaire must be
protected from constant pendulum movement due to wind.
- Lamp
- Module connected wattage 45.6 W
- Luminaire connected wattage 50.2 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
- 24 131 K3
- Module designation 8x LED-0884/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 9160 lm
- Luminaire luminous flux 8105 lm
- Luminaire luminous efficiency 161,5 lm / W
- 24 131 K4
- Module designation 8x LED-0884/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 9400 lm
- Luminaire luminous flux 8317 lm
- Luminaire luminous efficiency 165,7 lm / W
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.To achieve additional protection
against e. g. transients, etc. we recommend separate overvoltage protection
components. You can find them on our website at
www.bega.com.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Colour white White synthetic sphere Silicone gasket 4
drilled holes with thread M4 to which tension cables preventing pendulum
movement can be fixed Cable pendant H05RN-F 5 G 1@ with 2 steel cords · Colour
blackOverall length of luminaire approx. 4000 mm Mounting plate with 2 fixing
holes ø 5.5 mm · 70 mm spacing Mounting plate with 2 fixing holes ø 5.5 mm ·
70 mm spacing 2 cable entries for through-wiring of mains supply cable ø
7-10.5 mm, max. 5 G 1.5@ Connecting terminal 2.5@ with plug connection Earth
conductor connection BEGA Ultimate Driver® LED power supply unit 220-240 V x
0/50-60 Hz DC 176-264 V DALI-controllable Number of DALI addresses: 1 Basic
insulation is provided between the mains and control cables BEGA Thermal
Control® Temporary thermal regulation to protect temperature-sensitive
components without switching off the luminaire Safety class I Protection class
IP 64 Dust-tight and protection against splash water Impact strength IK10
Protection against mechanical impacts < 20 joule å – Safety markc –
Conformity mark Weight: 8.6 kg This product contains light sources of energy
efficiency class(es) C
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping. Insert
sphere into holder plate and adjust centrically. Tighten screws at the holder
plate evenly. Make sure that the gasket is positioned correctly.
For mains supply connection open the mounting box. Release steel cord 3 by
pushing the bushing ofthe cord spanner. If required on site, the steel wire 1
fixed to the back of the mounting plate must be firmly secured to a non-
flammable building component. Fix end of steel cord 1 on the back of mounting
plate 2 with hexagon socket head screw M5. Lead mains supply cable through the
compression nipple into the mounting plate. Fix the mounting plate with
enclosed or any other suitable fixing material onto the mounting surface.It is
absolutely essential to use the enclosed gaskets. Make earth conductor
connection and electrical connection. The two loose plug-in terminals marked
DALIare provided for digital control purposes. If these wires are not
assigned, the luminaire will work with full light output.Insert steel cord 3
into cord spanner up to the stop. Make earth conductor connection between
mounting box and the mounting plate. Push plug into the coupler up to the
stop. Make sure that the gasket is in correct position. Bolt mounting box
firmly onto the mounting plate.
To shorten the cable pendant
The cable must only be shortened within the mounting box. By pushing the
bushing of the cord spanner the steel cord 3 is released. Disconnect mains
supply cable from plug connection and earth conductor terminal. Loosen locking
screws – hexagon socket head screws M4 – for suspension cord. Pull suspension
cords out of lock holes. Screw off round nut 4 and pull cable with gasket out
of screw connection. Shorten cable to the desired length. Insert pressure disk
into the round nut and press gasket into the round nut. Grease connecting
cable somewhat and lead it through round nut and gasket. Tighten round nut as
far as it will go and screw it together with the mounting box. Strip lines and
pull suspension cords thightly into the lock holes at the cord holder. Tighten
locking screws M4 firmly. Shorten steel cords with excess length, protect with
end sleeves. Lay steel cord 3 around the cord holder in such a way that steel
cord 3 is led between the cord holder and the two suspension cords of the
cable pendant.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGAreplacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for theLED module. Inspect and, if
necessary, replace the luminaire gaskets. Defective glass must be replaced.
Close the luminaire.
Cleaning · Maintenance
Clean dirt and debris from the luminaire regularly with a clean, soft, lint-
free cloth that is kept damp throughout the cleaning. If possible, please use
water for this, adding alittle commercial dishwashing detergent. For lacquered
surfaces we recommend the use of BEGA Lacquer Care Set 71 179. Cleaning agents
containing solvents and high-pressure cleaners are unsuitable for cleaning and
maintenance.
- Spares
- White synthetic sphere 15 000 130 .6
- LED power supply unit DEV-0270/1050i
- LED module 3000 K LED-0884/830
- LED module 4000 K LED-0884/840
- Gasket sphere 83 000 781
- Gasket mounting box 83 001 903
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com