BEGA 12063.1 Indoor Recessed Ceiling Downlight Instruction Manual

June 13, 2024
BEGA

BEGA 12063.1 Indoor Recessed Ceiling Downlight Instruction Manual
BEGA 12063.1 Indoor Recessed Ceiling Downlight

DIMENSIONS

Dimensions

Application

Recessed ceiling luminaire · indoor luminaire with hand-blown crystal glass and metal housing for connection to external LED power supply unit.

A focusing / dispersing lens bundles the powerful LED light in the centre of the reflector for a direct proportion of downlight. At the same time, a proportion of the dispersed light is used to illuminate the luminaire glass and to generate the vertical illuminance. For installation into ceilings with a shallow depth in interior areas.

Product description

Ceiling trim ring made of metal, Colour white
Crystal glass with screw neck
Additional focusing / diffusing lens made of partially frosted crystal glass
Reflector made of pure, high-gloss anodized aluminium Silicone gasket
Fixing is achieved by using two adjustable wedge-shaped claws
Connecting cable with strain relief and plug
connector system for BEGA power supply unit,
on/off or DALI.
 Safety class III 3 c – Conformity mark
Weight: 0.9 kg

This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability fordamage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 9.5 W
  • Luminaire connected wattage 12 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=45 °C
  • When installed in heat-insulating
  • material ta max=25 °C

12 063.1K3

  • Module designation LED-0328/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1600 lm
  • Luminaire luminous flux 1144 lm
  • Luminaire luminous efficiency 95,3 lm/W

Lighting technology
Half beam angle 40°

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

A separate power supply unit is required to operate the luminaire.

For connection to external LED-power supply unit – accessory 13 176 or 13 203 – the luminaire is equipped with a 2-pin connector.

Note operating instructions of the LED-power supply units. Please note:

The black marked connector is not used to connect to the power supply unit 13 176 on/off

The recessed opening is covered by the frame of the luminaire housing. Fixing of the luminaire in the structure is achieved by using two adjustable wedgeshaped claws. Installation into concrete ceilings: For this purpose installation housing 13 025 is available.

Installation into inserted ceilings:

A recessed opening of ø 142 mm is necessary to accept the luminaire housing. Recessed depth min. 45 mm. The lateral distance between recessed luminaire and other building parts must be at least 50 mm.

The claws catch the ceiling facing from the back side. Minimum thickness of the ceiling facing is 3 mm. If the ceiling facing has a thickness of less than 10 mm or in case of an installation into plasterboard ceilings, the facing thickness in the region of the claws must be increased from the back side. Open luminaire:

Remove glass from luminaire housing by turning it counter-clockwise. Connect plug part of the luminaire with power supply unit.

Push external LED power supply unit and luminaire housing into the ceiling cut-out. Tighten evenly screws of claw fasteners. Impress the enclosed cover ring about the sealing ring onto the glass. Make sure that the sealing ring is seated correctly! Slide enclosed – separately packed – dispersing lens into the reflector. Screw glass with cover ring and dispersing lens into the luminaire housing.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.

The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.

The module can be replaced by qualified persons using standard tools.

Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.

Inspect and, if necessary, replace the luminaire gaskets.

Defective glass must be replaced. Close the luminaire

Accessories

Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system

13 176 Power supply unit on/off
13 203 Power supply unit DAL

The power supply units are only suitable for the operation of one LED luminaire.

13 025 Installation housing

For the accessories a separate instructions for use can be provided upon request.

Spares

  • Dispersing lens 11 003 040 10RG
  • Spare glass 11 003 047 42M1RG
  • LED module 3000 K LED-0328/930
  • Trim ring 72 000 158 .2L
  • Gasket glas 83 001 44

References