HYTRONIK HBIR29-2CH PIR Independent Motion Sensor Instruction Manual
- June 12, 2024
- HYTRONIK
Table of Contents
- Product Description
- App Features
- Hardware Features
- Technical Specifications
- Mechanical Structure & Dimensions
- Wire Preparation
- Placement Guide and Typical Range
- Detection Pattern & Optional Accessories
- Big and small silicon gasket used to make IP54 degree protection when
- Wiring Diagram
- Dimming Interface Operation Notes
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HYTRONIK HBIR29-2CH PIR Independent Motion Sensor Instruction Manual
Product Description
HBIR29/2CH is Bluetooth PIR standalone motion sensors with two independent channel outputs. One is DALI channel output (50mA DALI power supply built in), which can control up to 25 LED drivers. The other is voltage-free contact, which is NC (normally closed contact). It is ideal for typical indoor applications such as office, classroom, healthcare and other commercial areas. With Bluetooth wireless mesh networking, it makes communication between luminaires much easier without time-consuming hardwiring, which eventually saves costs for projects (especially for retrofit upgrade projects!). Meanwhile, simple device setup and commissioning can be done via app
App Features
Quick setup mode & advanced setup mode
Web app/platform for project deployment & data analysis
Koolmesh Pro app on iPad for on-site configuration
Floorplan feature to simplify project planning
coming soon
One-key device replacement
Device social relations check
Staircase function (primary & secondary)
Remote control via gateway support HBGW01
Heat map
Dynamic daylight harvest auto-adaptation
Grouping luminaires via mesh network
Scenes
Dusk/Dawn photocell (Twilight function)
Tri-level control
Daylight harvest
Circadian rhythm (Human centric lighting)
Push switch configuration
Detailed motion sensor settings
Schedule
Astro timer (sunrise and sunset)
Power-on status (memory against power loss)
Ofine commissioning
Bulk commissioning (copy and paste settings)
Different permission levels via authority management
Network sharing via QR code or keycode
Interoperability with Hytronik Bluetooth product portfolio
Compatible with EnOcean BLE switches
Internet-of-Things (IoT) featured
Device firmware update over-the-air (OTA)
Continuous development in progress.
Hardware Features
50mA DALI broadcast output
Support to control DT8 LED drivers
VFC: Volt-free Contact/Dry Contact ON/OFF relay switch:
− 24VDC@2A
− 250VAC@2A
NC contact
2 Push inputs for exible manual control
IP20/IP54 Ceiling/Surface mount box available as accessory
Various PIR lens and blind inserts options
User-friendly design for installation
High bay version available (up to 15m in height)
5-year warranty
Bluethooth 5.0 SIG mech
Smartphone app for both iOS & Android platform
Koolmesh Pro app for iPad
Web app/platform:www.iot.koolmesh.com
Technical Specifications
Bluetooth Transceiver
Operation frequency| 2.4 GHz – 2.483 GHz
Transmission power| 4 dBm
Range (Typical indoor| 10~30m
Protocol| 5.0 SIG Mesh
Sensor Data
Sensor Model| PIR detection
HBIR29/2CH| Installation Height : 6m
Detection Range(Ø) :9m
HBIR29/2CH/R| Installation Height : 6m
Detection Range(Ø) :10m
HBIR29/2CH/W| Installation Height : 6m
Detection Range(Ø) :18m
HBIR29/2CH/H| Installation height:15m (forklift)12m (person)
Detection range (Ø):24m
HBIR29/2CH/RH| Installation height:20m (forklift)12m (person)
Detection range (Ø):40m
Detection angle| 360O
Input & Output Characteristics
Operating voltage| 220~240VAC 50/60Hz
Load ratings| Channel 1: Max. 25 devices, 50mA
Channel 2: 24VDC@2A,250VAC@2A
Warming-up| 20s
Safety & EMC
EMC standard (EMC)| EN55015, EN61000, EN61547
Safety standard (LVD)| EN60669-1, EN60669-2-1 AS/NZS60669-1/-2-1
RED| EN300328, EN301489-1/-17
Certification| CB, CE, EMC, RED, RCM, UKCA
Environment
Operation temperature| Ta: -20OC ~ +50OC
IP rating| IP20
Mechanical Structure & Dimensions
- Ceiling (drill hole Ø 66~68mm)
- Carefully prise off the cable clamps.
- Make connections to the pluggable terminal blocks.
- Insert plug connectors and secure using the provided cable clamps, then clip terminal covers to the base.
- Fit detection blind (if required) and desired lens.
- Clip fascia to body.
- Bend back springs and insert into ceiling.
Wire Preparation
Pluggable screw terminal. It is recommended to make connections to the terminal before fitting to the sensor.
Placement Guide and Typical Range
The smart device with the App installed will have a typical range of 10m, but varies from device to device. During commissioning, the installer will need to be in range of the devices when searching for devices to add to the network.
Once the devices have been added to the network via the App, the devices will
start communicating within the wireless mesh.
This means that once the network is complete, all devices are accessible from
the smart device when in a 20m range of a single point.
Detection Pattern & Optional Accessories
HBIR29/2CH (Low-bay)
| HBIR29/2CH : Low-bay flat lens detection pattern for singl
e perso n @ Ta = 20OC (Recommended ceiling mount
installation height 2.5m-6m )
| | Mount height| Tangential (A)|
Radial (B)
2.5m| max 50m2 (Ø = 8m)| max 13m2 (Ø = 4m)
3m| max 64m2 (Ø = 9m)| max 13m2 (Ø = 4m)
4m| max 38m2 (Ø = 7m)| max 13m2 (Ø = 4m)
5m| max 38m2 (Ø = 7m)| max 13m2 (Ø = 4m)
6m| max 38m2 (Ø = 7m)| max 13m2 (Ø = 4m)
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
Blind Option 1 — Aisle Detection
Blind Option 2 — 180O Detection
| 2. HBIR29/2CH/R (Reinforced Low-bay)
---|---
HBIR29/2CH/R: Low-bay convex lens detection pattern for single person @
Ta = 20O C (Recommended ceiling mount installation height 2.5m-6m)
A: Tangential movement
| B: Radial movement
| Mount height| Tangential (A)|
Radial (B)
2.5m| max 79m2 (Ø = 10m)| max 20m2 (Ø = 5m)
3m| max 79m2 (Ø = 10m| max 20m2 (Ø = 5m)
4m| max 64m2 (Ø = 9m)| max 20m2 (Ø = 5m)
5m| max 50m2 (Ø = 8m)| max 20m2 (Ø = 5m)
6m| max 50m2 (Ø = 8m| max 20m2 (Ø = 5m
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
Blind Option 1 — Aisle Detection
Blind Option 2 — 180O Detection
Big and small silicon gasket used to make IP54 degree protection when
HBIR29/2CH series device mounted into HA03 housing for ceiling mount
| 3. HBIR29/2CH/W (Wide range Low-bay)
---|---
HBIR29/2CH/W: Low-bay convex lens detection pattern for single person @
Ta = 20O C (Recommended ceiling mount installation height 2.5m-6m)
A: Tangential movement
| B: Radial movemen
| Mount height| Tangential (A)|
Radial (B)
2.5m| max 254m2 (Ø = 18m)| max 28m2 (Ø = 6m)
3m| max 254m2 (Ø = 18m)| max 28m2 (Ø = 6m)
4m| max 154m2 (Ø = 14m| max 28m2 (Ø = 6m)
5m| max 113m2 (Ø = 12m)| max 28m2 (Ø = 6m)
6m| max 79m2 (Ø = 10m)| max 13m2 (Ø = 4m)
Optional Accessory — Ceiling/Surface Mount Box: HA03
| 4. HBIR29/2CH/H (High-bay)
---|---
HBIR29/2CH/H: High-bay lens detection pattern for forklift @ Ta = 20O C
(Recommended ceiling mount installation height 10m-15m)
A: Tangential movement
| B: Radial movement
| Mount height| Tangential (A)|
Radial (B)
10m| max 380m2 (Ø = 22m| max 201m2 (Ø = 16m)
11m| max 452m2 (Ø = 24m)| max 201m2 (Ø = 16m)
12m| max 452m2 (Ø = 24m)| max 201m2 (Ø = 16m)
13m| max 452m2 (Ø = 24m)| max 177m2 (Ø = 15m)
14m| max 452m2 (Ø = 24m)| max 133m2 (Ø = 13m)
15m| max 452m2 (Ø = 24m)| max 113m2 (Ø = 12m)
| HBIR29/2CH/H: High-bay lens detection pattern for single person @ Ta =
20O C (Recommended ceiling mount installation height 2.5m-12m
A: Tangential movement
| B: Radial movement
| Mount height| Tangential (A)|
Radial (B)
2.5m| max 50m2 (Ø = 8m)| max 7m2 (Ø = 3m)
6m| max 104m2 (Ø = 11.5m| max 7m2 (Ø = 3m)
8m| max 154m2 (Ø = 14m)| max 7m2 (Ø = 3m)
10m| max 227m2 (Ø = 17m)| max 7m2 (Ø = 3m)
11m| max 269m2 (Ø = 18.5m)| max 7m2 (Ø = 3m)
12m| max 314m2 (Ø = 20m)| max 7m2 (Ø = 3m)
Optional Accessory — Ceiling/Surface Mount Box: HA03
Optional Accessory — Blind Insert for Blocking Certain Detection Angles
Blind Option 1 — Aisle Detection
Blind Option 2 — 180O Detection
Big and small silicon gasket used to make IP54 degree protection when HBIR29/2CH series device mounted into HA03 housing for ceiling mount
Small silicon water-proof gasket dimension(size:mm
Big silicon water-proof gasket dimension(size:mm)
Wiring Diagram
Dimming Interface Operation Notes
Switch-Dim
The provided Switch-Dim interface allows for a simple dimming method using
commercially available non latching (momentary) wall switches. Detailed Push
switch congurations can be set on Koolmesh app.
Switch Function | Action | Descriptions |
---|---|---|
Push switch | Short press (<1 second)* Short press has to be longer than 0.1s, | |
or it will be invalid. | – Turn on/off – Recall a scene- Turn on |
only – Quit manual mode- Turn off only – Do nothing
Double push| – Turn on only – Quit manual mode- Turn off only
– Do nothing- Recall a scene
Long press (≥1 second)| – Dimming- Colour tuning- Do nothing
Simulate sensor| /| – Upgrade a normal on/off motion sensor to a Bluetooth
controlled motion sensor
Additional Information / Documents
-
To learn more about detailed product features/funcvtions, please refer to
www.hytronik.com/download ->knowledge ->Introduction of App Scenes and Product Functions -
Regarding precautions for Bluetooth product installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->Bluetooth Products – Precautions for Product Installation and Operation
-
Regarding precautions for PIR Sensors installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->PIR Sensors – Precautions for Product Installation and Operation
-
Data sheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/bluetooth technology ->Bluetooth Sensors
-
Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy
Subject to change without notice.
Edition: 19 Apri. 2022 Ver. A0 Page 8/8
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>