Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.

Function / Application
The thermal imaging camera provides visualization of temperature curves, energy losses, thermal bridges, electrical overloads, and moisture build-up. The infrared image, digital image, and mixed image allow the user to have a flexible illustration of the area under inspection. Images are stored on exchangeable Micro-SD cards. The device features a USB interface and a high- contrast, color TFT display.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture, or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.

Safety instructions
Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits values in accordance with EMC-Directive 2014/30/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations, or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera -
Overview

1. ON/OFF
2. 1,8“color display
3. Menu navigation/select digital image, overlay infrared / digital image
4. Menu/Control menu (Confirmation)
5. Menu navigation/select digital image, overlay infrared / digital image
6. Battery compartment| 7. Shaft
a. Mini USB interface
b. Micro-SD card slot
8. Control menu (cancel / back)
9. Infrared sensor
10. Digital camera
11. Trigger: save the image
---|---

Standard measurement view

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Standard
measurement view

  1. Battery charge indicator
  2. Micro-SD card not inserted
  3. The temperature at the center of the image
  4. Min. temperature
  5. Max. temperature
  6. Thermography image

Main Menu

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Main
Menu

  1. Change color palette
  2. Set emissivity coefficient
  3. Open media gallery/Delete images from micro-SD card
  4. Auto shutdown
  5. Set date/time

Inserting batteries

Open the battery compartment and insert batteries according to the symbols. Be sure to pay attention to polarity.

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Inserting
batteries

ON / OFF

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - ON
OFF

Inserting micro-SD card

To insert a micro-SD card, first, open the rubber cover and then insert the memory card as illustrated. You cannot record anything without a storage medium.

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Inserting micro
SD card The device must be switched off before removing the micro-SD.

Main menu

General and measurement-specific settings can be made in the main menu. The menu is controlled with four buttons (3, 4, 5, 8).

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Main menu
1

Colour ranges IR image

You can choose from several standard color ranges to represent the measured infrared temperatures. Depending on the color palette, the measured temperatures are adjusted within the current image section and displayed in the respective color space.

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Colour
ranges

Emissivity coefficient

The level of infrared emissions given off by everything depends on the specific material and surface. This factor is determined by the emissivity coefficient (0.10 … 1.0). For accurate measurements, it is absolutely essential that the emissivity coefficient is set first. The emissivity coefficient can either be custom set or selected from the predefined emissivity coefficients from the list.

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Emissivity
coefficient

| Confirmation
---|---
| Increase value
| Decrease value
| Cancel / back

Emission coefficient tables Reference values with tolerances

Metals

Alloy A3003| Iron, forged
Oxidized| 0.20| Matt| 0.90
Roughened| 0.20| Lead
Aluminum| Rough| 0.40
Oxidized| 0.30| Platinum
Polished| 0.05| Black| 0.90
Brass| Steel
Polished| 0.30| Cold rolled| 0.80
Oxidized| 0.50| Ground plate| 0.50
Chromium oxide| 0.81| Polished plate| 0.10
Copper| Alloy (8% nickel, 18% chromium)| 0.35
Oxidized| 0.72| Galvanised| 0.28
Copper oxide| 0.78| Oxidized| 0.80
Inconel| Heavily oxidized| 0.88
Oxidized| 0.83| Freshly rolled| 0.24
Electropolished| 0.15| Rough, flat surface| 0.96
Iron| Rusty, red| 0.69
Oxidized| 0.75| Sheet, nickel plated| 0.11
With rust| 0.60| Sheet rolled| 0.56
Iron, cast| Stainless steel| 0.45
Non-oxidized| 0.20| Zinc
Molten mass| 0.25| Oxidized| 0.10
Nonmetals

Asbestos| 0.93| Lime| 0.35
Asphalt| 0.95| Lime malm brick| 0.95
Basalt| 0.70| Limestone| 0.98
Brick, red| 0.93| Marble
Carborundum| 0.90| Black, dull finish| 0.94
Cement| 0.95| Greyish, polished| 0.93
Ceramics| 0.95| Masonry| 0.93
China| Paint
Brilliant white| 0.73| Black, matt| 0.97
With glaze| 0.92| Heat-resistant| 0.92
Clay| 0.95| White| 0.90
Coal| Paper
Non-oxidized| 0.85| All colors| 0.96
Concrete, plaster,| 0.93| Plastic
Cotton| 0.77| Translucent| 0.95
Earthenware, matt| 0.93| PE, P, PVC| 0.94
Fabric| 0.95| Quartz glass| 0.93
Glass| 0.90| Rubber
Glass wool| 0.95| Hard| 0.94
Graphite| 0.75| Soft, grey| 0.89
Gravel| 0.95| Sand| 0.95
Grit| 0.95| Screed| 0.93
Gypsum| 0.88| Snow| 0.80
Gypsum cardboard| 0.95| Soil| 0.94
Heat sink| Tar| 0.82
Black, anodized| 0.98| Tar paper| 0.92
Human skin| 0.98| Transformer paint| 0.94
Ice| Wallpaper, light-colored| 0.89
Clear| 0.97| Water| 0.93
With heavy frost| 0.98| Wood
Laminate| 0.90| Untreated| 0.88
Beech, planed| 0.94

Media gallery/playback mode

All image data recorded with the ThermoVisualizer Pocket is available in the media gallery.

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Media
gallery

| Confirmation
---|---
| Increase value
| Next image
| Cancel/back

To delete recording

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - delete
recording

The files are deleted immediately.
There is no prompt to confirm the deletion.

Auto power off

The device switches off automatically after a set period of inactivity.

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Auto power
off

Date / Time

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Date
Time

| Confirmation/next
---|---
| Increase value
| Decrease value
| Cancel/back

Image modes

There are 6 image modes to choose from.
A. IR image (Thermal image)
B. – E. Digital image with IR image overlay (MIX), 4 stages
F. Digital image (black/white)

Laserliner ThermoVisualizer Pocket Thermal Imaging Camera - Image
modes

Data transfer

Data saved on the micro-SD card can be transferred to a PC either with a suitable card reader or via the mini-USB port. Please refer to the manual supplied with your card reader for information about connecting your card adapter or card reader to a PC.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents, or solvents. Remove the battery(ies) before storing it for longer periods. Store the device in a clean and dry place.
Calibration
The measuring device must be calibrated and tested on a regular basis to ensure it is accurate and working properly. We recommend carrying out calibration once a year. Contact
your distributor or the UMAREX-LASER LINER service department.

Technical data
(Subject to technical changes without notice. Rev22W03)

Measured variable| Infrared temperature
Spectral range| 8-14 µm
Therm. sensitivity (NETD)| 150 mK
Measuring range infrared temperature| -20°C … 650°C
Accuracy infrared temperature| ≤100°C (± 3°C) /

100°C (± 3%)
Infrared temperature resolution| 0.1°C
Screen type| 1.8″ color TFT
Display resolution| 128 x 160 pixels
Image format| BMP
Image frequency| 9 Hz
Digital camera resolution| 640 x 480 pixels
Field of view (FOV)| 33°
Memory| Micro-SD memory card up to 16 GB
Protection class| IP 54
Sensor type| Thermoarray-Sensor
Power supply| 4 x 1.5V LR03 (AAA)
Operating time| approx. 100 hours
Operating conditions| 0°C … 50°C, max. humidity 20 … 85% RH, no condensation, max. working altitude 2000 m above sea level
Storage conditions| -10°C … 60°C, max. humidity 80% RH
Dimensions (W x H x D)| 70 x 180 x 46 mm
Weight| 175 g (incl. batteries)

EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: www.laserliner.com

SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: +49 2932 638-333
info@laserliner.com

Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300,
Fax: -333
www.laserliner.com

Rev22W03

Documents / Resources

| Laserliner ThermoVisualizer Pocket Thermal Imaging Camera [pdf] User Manual
ThermoVisualizer Pocket, Thermal Imaging Camera, Imaging Camera, Thermal Camera, ThermoVisualizer Pocket, Pocket
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals