BEGA 50 965.5 Indoor Track Spotlight Instruction Manual

June 12, 2024
BEGA

BEGA 50 965.5 Indoor Track Spotlight

BEGA-50-965-5-Indoor-Track-Spotlight-product

Product Information

Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients, etc., it is recommended to use separate overvoltage protection components. You can find them on our website at www.bega.com.

Technical Specifications

Lamp| Module Connected Wattage| Luminaire Connected Wattage| Rated Temperature| Ambient Temperature
---|---|---|---|---
LED-0986/930| 12.3 W| 14.5 W| 25°C| 60°C
LED-0986/940| 12.3 W| 14.5 W| 25°C| 60°C

Module Specifications

Module Designation| Colour Temperature| Colour Rendering Index (CRI)| Module Luminous Flux| Luminaire Luminous Flux| Luminaire Luminous Efficiency
---|---|---|---|---|---
LED-0986/930| 3000 K| CRI > 90| 1685 lm| 1315 lm| 90.7 lm/W
LED-0986/940| 4000 K| CRI > 90| 1710 lm| 1334 lm| 92 lm/W

Product Usage Instructions

  1. Screw enclosed trim ring with attached reflector into the luminaire housing by turning it clockwise until it stops, so that it is fixed by clamping.
  2. Place the surface washer adapter flush on the conductor rail in the desired position.
  3. Push the two fixing levers on the underside of the adapter to the right until they click into their end position.
  4. Set the desired LED beam direction by turning and tilting the luminaire housing.
  5. Move the two fixing levers in opposite directions until they disengage to unlock the adapter.

Application
Ceiling mounted track spotlight · indoor luminaire for 3-phase Eurostandard- Plus® track systems.
The optical system of the washer is swivel-mounted and rotatable.
Symmetrical wide beam light distribution. With BEGA Hybrid Optics® : Highly efficient and low-loss light distribution, thanks to reflector and optical lens.

Product description

  • Track spotlight with adapter
  • Cast aluminium luminaire housing,
  • finish Colour velvet black,
  • Polycarbonate track adapter with integrated LED power supply unit
  • Trim ring · Chrome finish
  • Clear safety glass
  • Optical silicone lens · BEGA Hybrid Optics® Reflector surface made of pure aluminium LED power supply unit
  • 220-240 V y 50/60 Hz
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • Safety class II 2
  • – Conformity mark
  • Weight: 0.9 kg
  • This product contains light sources of energy efficiency class(es) EBEGA-50-965-5-Indoor-Track-Spotlight-fig-1

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage: 12.3 W
  • Luminaire connected wattage: 14.5 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 60 °C

50 965.5 K3

  • Module designation: LED-0986/930
  • Colour temperature: 3000 K
  • Colour rendering index: CRI > 90
  • Module luminous flux: 1685 lm
  • Luminaire luminous flux: 1315 lm
  • Luminaire luminous efficiency: 90,7 lm / W

50 965.5 K4

  • Module designation: LED-0986/940
  • Colour temperature: 4000 K
  • Colour rendering index: CRI > 90
  • Module luminous flux: 1710 lm
  • Luminaire luminous flux: 1334 lm
  • Luminaire luminous efficiency: 92 lm / W

Light technique
Track spot · surface washer with adjustable optical system. Optical system 0-60° swivel-mounted and infinitely rotatable 360° around the vertical luminaire axis. Symmetrical wide beam light distribution. Half beam angle 32°

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. The track spotlight with adapter is ready for operation in 3-phase EUROSTANDARD-PLUS® track systems. The mounting is done without tools in the bus bar.

IMPORTANT:
Ensure that the adapter’s two lateral stays are located on the same side as the matching guide profile of the track before installing the adapter in the 3-phase EUROSTANDARD-PLUS® track system. To select the phase ( 1 2 3 ) the turning knob on the rear side of the adapter has to be operated accordingly. Screw enclosed trim ring with attached reflector into the luminaire housing by turning it clockwise until it stops, so that it is fixed by clamping. Place the surface washer adapter flush on the conductor rail in the desired position. Push the two fixing levers on the underside of the adapter to the right until they click into their end position. Set the desired LED beam direction by turning and tilting the luminaire housing. Move the two fixing levers in opposite directions until they disengage to unlock the adapter.

Cleaning · Maintenance

Clean the luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools. Disconnect the system and open the luminaire. Uninstall the reflector. Please follow the installation instructions for the LED module. Install the reflector. Defective glass must be replaced. Close the luminaire.

Spares

  • LED Power Supply Unit: DEV-0438/350
  • LED Module 3000 K: LED-0986/930
  • LED Module 4000 K: LED-0986/940
  • Reflector Unit: 75 003 701
  • Glass/Trim Ring: 75 003 796

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
[email protected] 
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals