BEGA 50537.1 LED Ceiling and Wall Luminaire for Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA 50537.1 LED Ceiling and Wall Luminaire for Indoor Use

Product Information

Parameter Value
Safety The installation and operation of this luminaire are subject to

national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage Protection| The electronic components installed in the luminaire are
protected against overvoltage in accordance with DIN EN 61547. To
achieve an additional protection against e.g. transients, etc. we
recommend separate overvoltage protection components. You can find
them on our website at www.bega.com.
Lamp Module Connected Wattage| 15.1 W
Luminaire Connected Wattage| 18 W
Rated Temperature| 25°C – 40°C
Ambient Temperature| ta max = 40°C
Module Designation| LED-0381/930
Colour Temperature| 3000 K
Colour Rendering Index (CRI)| CRI > 90
Module Luminous Flux| 2470 lm
Luminaire Luminous Flux| 1417 lm
Luminaire Luminous Efficiency| 78.7 lm / W

Product Usage Instructions

  1. Safety: The installation and operation of this luminaire must be carried out by a qualified electrician in accordance with national safety regulations. The manufacturer does not accept liability for damage caused by improper use or installation. If any modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.
  2. Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients and other factors, it is recommended to use separate overvoltage protection components. You can find these components on our website at www.bega.com.
  3. Installation: To install the luminaire, follow these steps: – Remove the luminaire housing with glass by turning it counter-clockwise. – During installation or relamping, avoid touching the light output opening of the LED directly as they are high-quality electronic components.
  4. Spares: The following spare parts are available for this luminaire: – Spare glass: Part number 11 002 865 11R – LED power supply unit: Part number G DEV-0312/500 – LED module 3000 K: Part number LED-0381/930 – Gasket: Part number 83 001 382

DIMENSIONS

BEGA-50537.1-LED-Ceiling-and-Wall-Luminaire-for-Indoor-Use-
FIG-1

Instructions for use

Application

  • Ceiling and wall luminaire· indoor luminaire with high protection class for a variety of lighting tasks.
  • A luminaire made of die cast aluminium and crystal glass.

Product Description

  • Aluminium alloy housing, finish Colour white
  • Crystal glass, inside white
  • Silicone gasket
  • 2 mounting holes ø 4.5 mm
  • Distance apart 200 mm
  • 2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@ Connection terminal 2.5@
  • Earth conductor connection
  • 2-pole connecting terminal for digital control
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK07
  • Protection against mechanical
  • impacts < 2 joule
  • – Safety mark
  •  – Conformity mark
  • Weight: 2.9 kg

This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 15.1 W
  • Luminaire connected wattage 18 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

50 537.1 K3

  • Module designation LED-0381/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 2470 lm
  • Luminaire luminous flux 1417 lm
  • Luminaire luminous efficiency 78,7 lm / W

Installation

Remove luminaire housing with glass from luminaire base by turning it counter- clockwise. LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

  • Disassemble LED module.
  • Lead the mains supply cable through the cable entry into the luminaire back housing.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied. Make the earth conductor connection and the electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • Assemble LED module.
  • Make sure that gasket is positioned correctly. Place luminaire housing with glass onto the luminaire base and turn it clockwise as far as it will go.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass 11 002 865 11R G
  • LED power supply unit DEV-0312/500
  • LED module 3000 K LED-0381/930
  • Gasket 83 001 382

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals