BEGA 51 097.1 LED Recessed Ceiling Downlight for Indoor Use
Dimension
Instructions for use
Application
Ceiling luminaire downlight · Indoor luminaire with symmetrical very wide beam
light distribution. Ready-to-connect set of 3 including external phase-
dimmable LED power supply unit and connection cables between the luminaires.
For installation in suspended ceilings of 3-18 mm in interior applications.
Product description
Set of 3 ready-to-connect recessed ceiling luminaire downlights including
external power supply unit Luminaire housing made of die-cast zinc finish
Colour velvet white The reflector surface made of pure aluminium Fixing is
achieved by using 2 fastening springs Recessed opening ø 57 mm Required
installation depth 48 mm Connection cable with 2-pole plug connector between
luminaires and external LED power supply unit (see sketch) External LED power
supply unit 220-240 V y 50-60 Hz Dimmable via a leading-edge or trailing-edge
dimmer Safety class II 2 c – Conformity mark Weight: 0.6 kg This product
contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e. g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
- Lamp
- Module connected wattage 1.9 W
- Luminaire connected wattage 8.2 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 50 °C
- When installed in heat-insulating
- material ta max = 35 °C
- 51 097.1 K27
- Module designation 3x LED-1208/927
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 840 lm
- Luminaire luminous flux 504 lm
- Luminaire luminous efficiency 61,5 lm / W
- 51 097.1 K3
- Module designation 3x LED-1208/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 900 lm
- Luminaire luminous flux 540 lm
- Luminaire luminous efficiency 65,9 lm / W
Lighting technology
Symmetrical wide beam light distribution Half beam angle 53°
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
The ready-to-connect set of recessed ceiling luminaires includes an external
phase dimmable LED power supply unit and connection cables with a 2-pole plug
connector between the luminaires and the LED power supply unit.
Installation in suspended ceilings:
For each luminaire, a recessed opening of 57 mm with a minimum depth of 48 mm
is required. The minimal thickness of the ceiling panel must be 3 mm and must
not be greater than 18 mm. A ceiling panel with less than 3 mm thickness must
be reinforced on the reverse. The electrical connection must be made on site
in the appropriate safety class on the LED power supply unit connecting cable.
A distribution box must be used. Ensure the correct assignment of the
connecting cable. Establish the mains connection on the brown (L) and blue (N)
wires. Guide the LED power supply unit and connection cable with distribution
boxes through the ceiling opening and deposit them in the suspended ceiling.
Make sure that the plug connectors between connection cables and distribution
boxes on the suspended ceiling are connected correctly before connecting the
recessed luminaires. The luminaires are interlinked in a series connections.
IMPORTANT: Make sure that the series circuit is closed via the plug with
wire jumper in the distribution box of the last luminaire.
Alternatively, plug this plug with wire jumper into the distribution box
socket of the last luminaire. Connect the plug of the first recessed luminaire
to the integrated socket of the first distribution box until the latch
engages. Proceed with additional luminaires in the same way. Cover the
recessed opening with the stop ring of the luminaire housing. The luminaire
housing is then fixed in the recessed opening via two springs. Compress the
fastening springs of the luminaire housing on both sides and slide the
luminaire housing into the recessed opening. The fastening springs lock into
place behind the ceiling panel.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Close the luminaire.
- Spares
- LED power supply unit DEV-0430/350
- Connecting cable 62 001 256
- Connecting cable 62 001 258
- Distributor 64 000 636
- Plug with wire jumper 64 000 637
- LED module 2700 K LED-1208/927
- LED module 3000 K LED-1208/930
- Retaining spring LED component 73 005 597
- LED component 75 004 495 K27
- LED component 75 004 495 K3
- Reflector 76 002 018
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>