BEGA 24 071 Wall Luminaire

BEGA-24-071-Wall-Luminaire-PRODUCT

Instructions for use

BEGA-24-071-Wall-Luminaire-FIG-1

Application

  • Shielded wall luminiaire with high protection class.
  • A luminaire made of aluminium alloy and crystal glass.

Lamp

  • Module connected wattage 11.3 W
  • Luminaire connected wattage 13.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 30 °C

24 071 K3

  • Module designatio n LED-0841/930
  • Colour temperature 3 000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1915 lm
  • Luminaire luminous flux 938 lm
  • Luminaire luminous efficiency 69,5 lm / W

24 071 K4

  • Module designation LED-0841/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 2030 lm
  • Luminaire luminous flux 994 lm
  • Luminaire luminous efficiency 73,6 lm / W

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Crystal glass coated 2 mounting holes ø 6 mm
  • Distance apart 180 mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm
  • Connection terminal 2.5@
  • Earth conductor connection
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets r – Safety mark
    • c  – Conformity mark
    • Weight: 3.7 kg
      This product contains light sources of energy efficiency classes C, D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at: www.bega.com.

Installation

  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Take note of the cover frame fixing screw positions when installing the luminaire base (see sketch).
  • Undo screws.
  • Remove luminaire top and glass.
  • Undo screws key slots and remove the LED-unit.
  • Disconnect plug connection.
  • Lead the mains supply cable through the cable entry of the luminaire base.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied. Make earth conductor connection.
  • Push silicone sleeves over the lines and make electrical connection.
  • Push plug into coupler as far as it will go. Reassemble LED-unit and tighten fixing screws firmly and evenly. Please observe that the LED board is not damaged mechanically.
  • Make sure that the gasket is in correct position. Install luminaire top with glass and tighten screws evenly.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.
  • Replacing the LED module
  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass 11 003 285 11
  • LED power supply unit DEV-0150/700
  • LED module 3000 K LED-0841/930
  • LED module 4000 K LED-0841/940
  • Gasket 83 001 667