Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.

Product description

Metal housing, finish Colour white Hand-blown opal glass, satin matt, with bayonet closure 2 mounting holes ø 5.5mm Distance apart 230mm 2 cable entries for through-wiring for mains cable up to ø 11 mm max. 5 x 1.5@ Connection terminal 2.5@ Earth conductor connection 2-pole connecting terminal for digital control LED power supply unit 220-240 V x 0/50-60 Hz DALI-controllable Basic insulation is provided between the mains and control cables BEGA Thermal Switch® Temporary thermal shutdown to protect temperature-sensitive components Safety class I Impact strength IK06
Protection against mechanical impacts < 1 joule
Safety mark

Conformity mark
Weight: 2.4 kg
This product contains light sources of energy efficiency class(es) D, E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 16.4 W
  • Luminaire connected wattage 19.6 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=30 °C

50 507K27

Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 2335 lm
Luminaire luminous flux 1743 lm
Luminaire luminous efficiency 88,9 lm/W

50 507K3

  • Colour temperature 3000 K
  • Colour rendering index CRI >90
  • Module luminous flux 2415 lm
  • Luminaire luminous flux 1803 lm
  • Luminaire luminous efficiency 92 lm/W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Lead mains supply cable through the cable entry into the luminaire housing. Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface. It is imperative to use the enclosed gaskets. Make earth and electrical connection to the terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Place glass to the luminaire housing and observe that the cam pins fit into the notches of the glass.
Screw in glass by turning it clockwise. Thus,
you reach a safe and vibration-resistant holding of the glass.

To release the glass from the luminaire housing turn it counter-clockwise.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire. The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.Disconnect from main supply. Unscrew glass from luminaire housing by turning it counter-clockwise. Replace the LED unit.
Screw in glass by turning it clockwise. Defective glass must be replaced.

Spares
Spare glass 11 003 569 .0RG LED unit 2700 K 75 001 904 .1K 27 LED unit 3000 K 75 001 904 .1K 3

2/2 BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden·
info@bega.com
www.bega.com

Ceiling and wall luminaire for indoor use Technical amendments reserved

Documents / Resources

| BEGA 50 507 PRIMA Ceiling and Wall Luminaires [pdf] Instruction Manual
50 507 PRIMA Ceiling and Wall Luminaires, 50 507, PRIMA Ceiling and Wall Luminaires, Ceiling and Wall Luminaires, Wall Luminaires
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals