Instructions for use
Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass
and metal housing, for all lighting tasks. They are ideal for places where a
soft and uniform lighting distribution is required.
Product description
Metal housing, finish Colour white Hand-blown opal glass, satin matt, with
bayonet closure 2 mounting holes ø 5.5mm Distance apart 230mm 2 cable entries
for through-wiring for mains cable up to ø 11 mm max. 5 x 1.5@ Connection
terminal 2.5@ Earth conductor connection 2-pole connecting terminal for
digital control LED power supply unit 220-240 V x 0/50-60 Hz DALI-controllable
Basic insulation is provided between the mains and control cables BEGA Thermal
Switch® Temporary thermal shutdown to protect temperature-sensitive components
Safety class I Impact strength IK06
Protection against mechanical impacts < 1 joule
Safety mark
Conformity mark
Weight: 2.4 kg
This product contains light sources of energy efficiency class(es) D, E
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e.g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
Lamp
- Module connected wattage 16.4 W
- Luminaire connected wattage 19.6 W
- Rated temperature ta=25 °C
- Ambient temperature ta max=30 °C
50 507K27
Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 2335 lm
Luminaire luminous flux 1743 lm
Luminaire luminous efficiency 88,9 lm/W
50 507K3
- Colour temperature 3000 K
- Colour rendering index CRI >90
- Module luminous flux 2415 lm
- Luminaire luminous flux 1803 lm
- Luminaire luminous efficiency 92 lm/W
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping. Lead
mains supply cable through the cable entry into the luminaire housing. Fix the
luminaire housing with enclosed or any other suitable fixing material onto the
mounting surface. It is imperative to use the enclosed gaskets. Make earth and
electrical connection to the terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Place glass to the luminaire housing and observe that the cam pins fit into
the notches of the glass.
Screw in glass by turning it clockwise. Thus,
you reach a safe and vibration-resistant holding of the glass.
To release the glass from the luminaire housing turn it counter-clockwise.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire. The
light colour and light output of BEGA replacement units correspond to those of
the LED units originally fitted. The LED unit can be replaced by qualified
persons using standard tools.Disconnect from main supply. Unscrew glass from
luminaire housing by turning it counter-clockwise. Replace the LED unit.
Screw in glass by turning it clockwise. Defective glass must be replaced.
Spares
Spare glass 11 003 569 .0RG LED unit 2700 K 75 001 904 .1K 27 LED unit 3000 K
75 001 904 .1K 3
2/2 BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden·
info@bega.com
www.bega.com
Ceiling and wall luminaire for indoor use Technical amendments reserved
Documents / Resources
| BEGA
50 507 PRIMA Ceiling and Wall
Luminaires
[pdf] Instruction Manual
50 507 PRIMA Ceiling and Wall Luminaires, 50 507, PRIMA Ceiling and Wall
Luminaires, Ceiling and Wall Luminaires, Wall Luminaires
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>