Product Information
- Product Name: Ceiling and Wall Luminaire with Emergency Lighting
- Product Description: Metal housing, finish color white. Hand-blown opal glass, satin matt, with bayonet closure. Distance apart 340 mm. Earth conductor connection. Emergency lighting module with self-test facility. NiMH accumulator for 3 hours. LED power supply unit. Safety class I. Impact strength IK07.
- Weight: 4.2 kg
- Energy Efficiency Class: D
Product Usage Instructions
- Safety Precautions:
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning should only be carried out by a qualified electrician.
- The manufacturer is not liable for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications is considered the manufacturer.
Dimension
Instructions for use
Application
Ceiling and wall luminaire with emergency lighting according to DIN EN
60598-2-22 and DIN VDE 0108-100 for safety lighting facilities. With integral
accumulator for 3 hours emergency operation in case of mains failure.
Product description
Metal housing, finish Colour white Hand-blown opal glass, satin matt, with
bayonet closure 2 mounting holes ø 6 mm Distance apart 340 mm 2 cable entries
for through-wiring for mains cable up to ø 10.5 mm max. 4 × 1.5@ Connection
terminal 2.5@ Earth conductor connection Emergency lighting module with self
test facility 220-240 V y 50/60 Hz NiMH accumulator for 3 hours emergency
operation at 5°…+25 °C LED power supply unit 220-240 V y 50/60 Hz Safety class
I Impact strength IK07 Protection against mechanical impacts < 2 joule c –
Conformity mark Weight: 4.2 kg This product contains light sources of energy
efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e. g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
- Lamp
- Module connected wattage 27.6 W
- Luminaire connected wattage 33.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 25 °C
- 50 736 K27
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 4165 lm
- Luminaire luminous flux 2730 lm
- Luminaire luminous efficiency 81,5 lm / W
- 50 736 K3
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 4305 lm
- Luminaire luminous flux 2822 lm
- Luminaire luminous efficiency 84,2 lm / W
- With emergency lighting, a luminous flux of 319 lm is achieved.
- X self-contained
- 0 non-maintained
- 1 maintained
- A including test device
- B including remote rest mode
- 180 to indicate 3 h duration
The above mentioned label is stuck to the luminaire as identification of the
emergency light mode. The identical label included with the luminaire and the
label concerning voltage and frequency (220-240 V y 50/60 Hz) must be attached
to the luminaire so that they are clearly visible from the outside. If the
luminaire is operated in continuous mode, the “0” on the above mentioned
labels must be covered with the enclosed “1” stickers.
Notice prior to installation:
The accumulator is supplied partially charged. In order to avoid an early
discharge of theaccumulator by the charging unit, a plug connector has been
unplugged from the accumulator. Before setting the luminaire into operation
this plug needs to be plugged-in again.
Luminaire with trim ring:
Before installing onto the mounting surface the luminaire housing must be
inserted into the trim ring (accessory).
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping. Lead the
mains supply cable through the cable entry into the luminaire housing. Secure
the luminaire housing to the installation surface with the fixing materials
provided or other suitable materials. It is imperative to use the enclosed
gaskets. Dismantle the mains supply cable approx. 60 mm. Push silicone sleeves
over the lines. Make the earth conductor connection and the electrical
connection.
It is important to ensure that the wires L and L’ are fed from the same
phase (in-phase)!
If the luminaire is operated in a continuous mode, the connection must be made
according to the sketch on the left. If the luminaire is operated in standby
mode, the jumper wire is to be connected to terminal L’ and the factory-set
jumper between L’ and Lis to be removed. When the luminaire is operated with
an external switch (switched maintained light), the factory-set jumper must
also be removed.
Place glass to the luminaire housing and observe that the cam pins fit into the notches of the glass.Screw in glass by turning it clockwise. Thus, you reach a safe and vibration-resistant holding of the glass. To release the glass from the luminaire housing turn it counter-clockwise.
Startup procedure
After installation of the luminaire and initial connection of the mains supply
and battery supply to the EM converterLED the unit will commence charging the
batteries for 20 hours (initial charge). Afterwards the module will conduct a
startup procedure test for the full duration. The 20 hours recharge occurs
also if a new battery is connected or the module exits the rest mode
condition. The following automatic startup procedure test is only performed
when a battery is replaced and fully charged (after 20 hours). The easy
startup procedure feature will set the initial test day and time to ensure
ransom testing of units. To decouple the actual starting time of the initial
installation from former building phases, the starting time at the module is
only set after 5 days continuous permanent voltage. Further information
concerning “rest mode”, technical data, storage, service life, etc. of the
emergency lighting module can be found under
www.tridonicatco.com.
Status indication
System status is indicated by a bi-colour LED.
Testing
This luminaire has a self-test function to comply with statutory
requirements.This self-test is performed weekly (function test) and annually
(operating period test). The function test is performed once a week for 5
seconds and is controlled by the microprocessor. The initiation including date
and time of this test is performed when the luminaire is commissioned. A
complete operating period test is performed annually to check the battery
power.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective
glass must be replaced.
Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.The light
colour and light output of BEGA replacement units correspond to those of the
LED units originally fitted. The LED unit can be replaced by qualified persons
using standard tools. Disconnect from main supply. Unscrew glass from the
luminaire housing by turning it counterclockwise. Replace the LED unit.Screw
in glass by turning it clockwise. The defective glass must be replaced.
Accessory · Trim rings
For this luminaire metal trim rings in 3 enamel surfaces are optional
available. Trim rings are accessories and must be ordered separately.
- Item Part. No
- Colour white 13 007
- Colour palladium 13 008
- Colour glossy silver 13 009
Spares
-
* Spare glass 11 003 539 .0R G
- LED power supply unit DEV-0277/700
- Rechargeable battery 61 001 208
- Emergency lighting module 61 001 864
- LED module 2700 K LED-0630/927
- LED module 3000 K LED-0630/930
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>