BEGA 50653.2 Ceiling and Wall Luminaire Instructions

June 12, 2024
BEGA

BEGA-LOGO

BEGA 50653.2 Ceiling and Wall Luminaire

Product Information

The product is a luminaire that requires installation and operation according to national safety regulations. It should only be installed and commissioned by a qualified electrician. The manufacturer is not liable for any damages caused by improper use or installation. Additional overvoltage protection components are recommended for protection against transients.

The luminaire has the following specifications:

  • Lamp Module connected wattage: 16 W
  • Luminaire connected wattage: 18.5 W
  • Rated temperature: 25°C
  • Ambient temperature: 30°C
  • Module designation: LED-0569/930
  • Colour temperature: 3000 K
  • Colour rendering index (CRI): > 90
  • Module luminous flux: 2440 lm
  • Luminaire luminous flux: 1333 lm
  • Luminaire luminous efficiency: 72.1 lm / W

Product Usage Instructions

  1. Place the glass to the luminaire housing.
  2. Ensure that the holding spring bolts fit into the notches of the glass.
  3. Turn the glass clockwise until it is locked for safe and vibration-resistant holding.
  4. To release the glass from the luminaire housing, turn it counterclockwise.

Dimension

BEGA-50653.2-Ceiling-and-Wall-Luminaire-FIG-1

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.
Product description
Metal housing, finish Colour white aluminium Hand-blown opal glass, satin matt, with sliding-bolt closure 2 mounting holes ø 5.5 mm Distance apart 200 mm 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@ Connecting terminal 2.5@ with plug connection Earth conductor connection LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V BEGA Thermal Switch® Temporary thermal shutdown to protect temperature-sensitive components Safety class I Protection class IP 44 Protected against granular foreign bodies ≥ 1 mm and splash water Impact strength IK05 Protection against mechanical impacts < 0.7-joule r – Safety mark c – Conformity mark Weight: 3.1 kgThis product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

  • Lamp
    • Module connected wattage 16 W
    • Luminaire connected wattage 18.5 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 30 °C
  • 50 653.2 K3
    • Module designation LED-0569/930
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 2440 lm
    • Luminaire luminous flux * 1333 lm
    • Luminaire luminous efficiency * 72,1 lm / W
    •  preliminary data

Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Disassemble LED module. Loosen LED-connection and earth connection (plug connection). Dismantle the mains supply cable max. 80 mm. Lead mains supply cable through the cable entry into the luminaire housing. Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface. It is imperative to use the enclosed gaskets. Make earth and electrical connection to the terminal. Make earth connection between LED module and luminaire housing (plug connection). Push LED-plugs into couplers as far as it will go. Assemble LED module. Tighten the screws evenly (max. 0,8 Nm). Please observe that the LED module is not damaged mechanically. Insert the opal glass into the luminaire housing with sliding bolt glass closure and turn the glass clockwise up to the stop. Place glass to the luminaire housing and observe that the holding spring bolts fit into the notches of the glass. Turn the glass clockwise until it is locked. Thus, you reach a safe and vibration-resistant holding of the glass. To release the glass from the luminaire housing, turn it counterclockwise.

Replacement of the LED module

Maintenance The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system. Unscrew glass from luminaire housing by turning it counter-clockwise. Clean glass and luminaire regularly with solvent-free cleansers from dirt. Please follow the installation instructions for the LED module.  Screw in glass by turning it clockwise as far asit will go. A broken glass must be replaced.

  • Spares
    • Spare glass 11 002 770 .0R G
    • LED power supply unit DEV-0150/700
    • LED module 3000 K LED-0569/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com