BEGA 34864 LED Recessed Ceiling Luminaire for Indoor Use Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 34864 LED Recessed Ceiling Luminaire for Indoor Use Instruction
Manual
Application
Recessed ceiling luminaire · indoor luminaire with hand-blown opal glass, satin matt and metal housing for connection to external LED power supply unit.
They are ideal for places where a soft and uniform lighting distribution is required.
For installation into ceilings with a shallow depth in interior areas.
Product description
Luminaire housing made of metal Opal glass, satin matt, with screw neck Silicone gasket
Fixing is achieved by using three adjustable wedge-shaped claws 2 connecting cables with strain relief and plug connector system for BEGA power supply unit, on/off or DALI
Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
A separate power supply unit is required to operate the luminaire
– accessory 13 202 or 13 174.
For connection to external LED-power supply unit the luminaire is equipped with two 2-pin connectors. Note operating instructions of the LED-power supply units.
Please note:
The black marked connector is not used to connect to the power supply unit 13
202 on/off.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using three adjustable wedgeshaped claws.
Installation into concrete ceilings:
For this purpose installation housing 13 018 is available.
Installation into inserted ceilings:
A recessed opening of ø 208 mm is necessary to accept the luminaire housing.
Recessed depth min. 45 mm.
The lateral distance between recessed luminaire and other building parts must be at least 50 mm.
The claws catch the ceiling facing from the back side. Minimum thickness of the ceiling facing is 3 mm. If the ceiling facing has a thickness of less than 10 mm or in case of an installation into plasterboard ceilings, the facing thickness in the region of the claws must be increased from the back side.
Open luminaire:
Remove glass from luminaire housing by turning it counter-clockwise.
Connect plug part of the luminaire with power supply unit.
Push external LED power supply unit and luminaire housing into the ceiling cut-out.
Luminaire housing and external LED power supply unit must not be installed in
heat-insulating material.
Tighten evenly screws of claw fasteners.
Screw glass with gasket into luminaire housing.
Make sure that gasket is positioned correctly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain
relief and plug connector system.
13 202 Power supply unit on/off 13 174 Power supply unit DALI
The power supply units are only suitable for the operation of one LED luminaire. 13 018 Installation housing
For the accessories a separate instructions for use can be provided upon request.
Spares
Spare glass 11 003 088 40M RG
LED module 3000 K LED-0327/930
Gasket glas 83 001 447
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>