BEGA 50714.2 Recessed Ceiling Luminaire for Indoor Use Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 50714.2 Recessed Ceiling Luminaire for Indoor Use
Product Information
Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
- Lamp Module connected wattage: 8.5 W
- Luminaire connected wattage: 10.4 W
- Rated temperature: Ambient temperature: 25-35°C
Lamp Module:
- Module designation: LED-0923/927
- Color temperature: 2700 K
- Color rendering index (CRI): > 90
- Module luminous flux: 1155 lm
- Luminaire luminous flux: 581 lm
- Luminaire luminous efficiency: 55.9 lm/W
Lamp Module:
- Module designation: LED-0923/930
- Color temperature: 3000 K
- Color rendering index (CRI): > 90
- Module luminous flux: 1200 lm
- Luminaire luminous flux: 604 lm
- Luminaire luminous efficiency: 58.1 lm/W
Ersatzteile (Replacement parts):
- Ersatzglas (Replacement glass): 11 003 006
- LED-Netzteil (LED power supply): 410 RG DEV-0434/250
- LED-Modul 2700 K (LED module 2700 K): LED-0923/927
- LED-Modul 3000 K (LED module 3000 K): LED-0923/930
- Abschlussring (End ring): 72 009 802 L
- Reflektor (Reflector): 76 001 209
Product Usage Instructions
Installation:
- Luminaire housing must not be installed in heat-insulating material.
- The recessed opening will be covered by the attachment of the installation ring.
- Fixing of the luminaire is achieved by using 2 adjustable claws.
- LEDs are high-quality electronic components! Please avoid touching them directly during installation or relamping.
- Push external LED-power supply unit and luminaire housing into ceiling cut-out.
- Luminaire housing and external LED power supply unit must not be installed in heat-insulating material.
- Tighten screws of claw fasteners evenly.
- Insert glass with mounted reflector by turning it clockwise into luminaire housing.
- Make sure that the gasket is positioned correctly.
- Mount the ceiling frame ring (magnetic) onto the installation ring of the housing.
Recessed ceiling luminaire for indoor use
Instructions for use
Application
Pivoting recessed ceiling luminaire · indoor luminaire partially satin matt
crystal glass inside and aluminum alloy housing.
Efficient luminaires for adjustable, brilliant light in the residential living
space and for use in many other ranges of interior illumination.
For installation into ceilings with a shallow depth in interior areas.
Product description
- Recessed ceiling luminaire »ACCENTA VARIO« Die-cast aluminum housing
- Crystal glass, partially satin matt inside Reflector of anodized pure aluminum
- Ceiling frame ring made of stainless steel Recessed opening ø 95 mm
- Required installation depth 60 mm
- Fixing is achieved by using 2 adjustable claws
- External LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-280 V
- DALI controllable
- A basic isolation exists between power cable and control line
- Safety class II
- Safety mark
- CE– Conformity mark
- Weight: 0.6 kg
- This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 8.5 W
- Luminaire connected wattage 10.4 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 35 °C
50 714.2 K27
- Module designation LED-0923/927
- Color temperature 2700 K
- Color rendering index CRI > 90
- Module luminous flux 1155 lm
- Luminaire luminous flux 581 lm
- Luminaire luminous efficiency 55,9 lm / W
50 714.2 K3
- Module designation LED-0923/930
- Color temperature 3000 K
- Color rendering index CRI > 90
- Module luminous flux 1200 lm
- Luminaire luminous flux 604 lm
- Luminaire luminous efficiency 58,1 lm / W
Installation
Luminaire housing must not be installed in heat-insulating material.
The recessed opening will be covered by the attachment of the installation
ring.
Fixing of the luminaire is achieved by using 2 adjustable claws.
LEDs are high-quality electronic components! Please avoid touching them
directly during installation or relamping.
Installation into false ceilings
A recessed opening of Ø 95 mm is necessary to accept the luminaire housing.
Free space depth min. 60 mm.
The claws catch the panel from the reverse side.
If minimum thickness of the panel is less than 3 mm it must be reinforced from
the reverse side. Maximum thickness of the panel must be no more than 20 mm.
The notch in the installation ring indicates the direction of maximum pivoting
range (35°) of the luminaire housing.
Remove glass with reflector from luminaire housing by turning counter-
clockwise.
The electrical connection must be made on site in the appropriate safety class
on the LED power supply unit connecting cable. A distribution box must be
used.
Ensure the correct assignment of the connecting cable. Establish the mains
connection on the brown (L) and blue (N) wires. The connection of the control
cables is achieved by means of the both leads marked with – DALI.
In case these leads are not used the luminaire will be operated at full light
output.
Push external LED-power supply unit and luminaire housing into ceiling cut-
out. Luminaire housing and external LED-power supply unit must not be
installed in heat-insulating material.
Hand-tight screws of claw fasteners evenly. Insert glass with mounted
reflector by turning it clockwise into luminaire housing.
Make sure that gasket is positioned correctly. Mount ceiling frame ring
(magnetic) onto installation ring of the housing.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light color and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect from main supply.
Remove glass with reflector from housing by turning it counter-clockwise.
Pull ceiling frame ring off the installation ring of the pivoting housing.
Please follow the installation instructions for the LED module.
Check gasket. Screw in glass with mounted reflector by turning it clockwise
into luminaire housing.
Mount ceiling frame ring onto installation ring of the housing.
Defective glass must be replaced.
Spares
- Spare glass 11 003 006 410 RG
- LED power supply unit DEV-0434/250
- LED module 2700 K LED-0923/927
- LED module 3000 K LED-0923/930
- Trim ring 72 009 802 L
- Reflector 76 001 209
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>