PRODUCT

Product Information

  • Product Name: 50 844.6 K3
  • Module Designation: 6x LED-0931/930
  • Color Temperature: 3000 K
  • Colour Rendering Index (CRI): > 90
  • Module Luminous Flux: 10050 lm
  • Luminaire Luminous Flux: 7047 lm
  • Luminaire Luminous Efficiency: 95.2 lm/W

Product Usage Instructions

  1. Safety: The installation and operation of this luminaire should be done according to national safety regulations. Only a qualified electrician should perform the installation and commissioning. The manufacturer is not liable for damage caused by improper use or installation. Any modifications made to the luminaire should be done by a responsible person who will be considered the manufacturer.
  2. Overvoltage Protection: The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website at  www.bega.com.
  3. Prior to Installation: Ensure that the ceiling surface has sufficient load-bearing capacity before mounting the luminaires. After installation, check the secure mounting of the luminaires.
  4. Installation: Do not install the luminaire housing in heat-insulating material. Avoid touching the light output opening of the LED directly during installation or relamping.
  5. Remove the luminaire housing from its packaging. Depending on on-site requirements, secure the steel wire affixed to the top of the housing to a non-flammable building component. Cover the recessed opening with the stop ring of the housing. Fix the housing in the recessed opening using four adjustable springs.
  6. Important: Place four protective adhesive foils in the areas where the fastening springs will be screwed into the housing to protect the inner surface during installation.
  7. Unpacking: To prevent deformation caused by its own weight, do not place the luminaire on its curved synthetic cover when outside the packaging.
  8. Spares: The following spares are included: Synthetic cover, LED power supply unit, LED module 3000 K, Installation housing.

Large-area recessed ceiling luminaire for indoor use

BEGA-50-844.6-Large-Area-Recessed-Ceiling-Luminaire-for-Indoor-
FIG-1

Instructions for use

Application
Recessed ceiling luminaire · indoor luminaire with impact-resistant synthetic diffuser, translucent white, aluminum housing, and with a remote external LED power supply unit. For installation in suspended ceilings of 12-25 mm in interior applications.

Product Description

  • Recessed ceiling luminaire »STUDIO LINE« with a remote power supply unit Luminaire housing made of aluminum inside hue matt copper
  • Recessed opening ø 630 mm
  • Required installation depth 205 mm
  • Luminaire housing with 4 fastening springs and guide bolts
  • Luminaire with an impact-resistant cover made of synthetic material, translucent white with bayonet closure
  • External LED power supply unit 1600 mA 220-240 V x 0/50-60 Hz
  • DC 176-270 V
  • During DC operation the LED power is reduced to 15 %

DALI controllable

Basic isolation exists between the power cable and the control line

BEGA Thermal Control
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire

  • Safety class I
  • Impact strength IK07
  • Protection against mechanical
  • impacts < 2 joule
  • c  – Conformity mark
  • Weight: 9.7 kg
  • This product contains light sources of energy efficiency class(es)

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 66.6 W
  • Luminaire connected wattage 74 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

50 844.6 K3

  • Module designation 6x LED-0931/930
  • Color temperature 3000 K
  • Color rendering index CRI > 90
  • Module luminous flux 10050 lm
  • Luminaire luminous flux 7047 lm
  • Luminaire luminous efficiency 95,2 lm / W

Notice prior to installation
When mounting the luminaires, it must be ensured that the ceiling surface has sufficient load-bearing capacity. Please check the secure mounting of the luminaires after installation.

Installation

Luminaire housing must not be installed in heat-insulating material. LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Remove the luminaire housing (installation housing) from its packaging. Depending on on- site requirements, the steel wire affixed to the top of the luminaire housing can be secured to a non-flammable building component (see drawing). Cover the recessed opening with the stop ring of the luminaire housing. The luminaire housing is then fixed in the recessed opening via four adjustable springs.

IMPORTANT
Place the four protective adhesive foils in the areas where the fastening springs will be screwed into the luminaire housing. This will protect the inner surface of the luminaire housing during installation in the recessed opening.

Installation into inserted ceilings
A recessed opening of 630 mm with a minimum depth of 205 mm is required. Push luminaire housing into the ceiling cut-out and tighten evenly the hexagon socket head screws (wrench size 4) of the four mounting springs. The mounting springs catch the ceiling facing from the back side. The minimum thickness of the panel must be 12 mm and the maximum thickness 25 mm. If the ceiling facing has a thickness of less than 3 mm, the facing thickness in the region of the mounting springs must be increased from the back side. Pass the power connecting cable through the opening in the installed luminaire housing.

Unpack luminaire

IMPORTANT: In order to prevent deformation caused by the luminaire’s own weight, do not place it on its curved synthetic cover when outside the packaging! Remove the adhesive protective foils and replace them with an offset below the four openings on the edge of the housing. Open the cover of the external LED power supply unit. Make the earth conductor and electrical connection via terminals on the external power supply unit. For digital control please use the
connecting terminals DA, and DA at the power supply unit.

In case these connectors are not used the luminaire will be operated at full light output. Close the cover of the external LED power supply unit. Luminaire housing and external LED power supply unit must not be covered by any heat- insulating materials. Guide the LED power supply unit through the opening of the luminaire housing and position it on the suspended ceiling. Pick up the luminaire and carefully guide it into the luminaire housing, taking care not to damage the colored surface. The four retaining plates of the luminaire must fit exactly into the four openings on the top edge of the housing. Secure the luminaire by lifting it over the locking pins and with a twist to the right until you feel a stop. The luminaire will now be held securely in place and will be resistant to vibration. Remove all protective foil from inside the luminaire housing once the luminaire is fully installed in the luminaire housing. The luminaire is removed by lifting it over the locking pins and twisting it anti-clockwise.

Cleaning · Maintenance

Clean the luminaire regularly with solvent-free cleaning agents to remove dirt. A defective synthetic cover must be replaced.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. A qualified person using standard tools can easily do the replacement. Disconnect the system from the power supply. Twist the luminaire anti-clockwise to remove it from the luminaire housing. Loosen the hex nuts (M4), remove the three sections of the trim ring, and lift off the synthetic luminaire cover. Remove the LED module. Install the replacement LED module. Please follow the installation instructions for the LED module. Twist the luminaire in the luminaire housing to the right to secure it. A defective synthetic cover must be replaced. Close up the luminaire again in reverse order.

Spares
Synthetic cover 15 000 347 B1
LED power supply unit DEV-0403/1600i
LED module 3000 K LED-0931/930