LARK 85560LCB LED Vanity Vera Instruction Manual
- June 12, 2024
- LARK
Table of Contents
LARK 85560LCB LED Vanity Vera
Product Information
The product is a fixture that requires assembly and mounting. It is designed for indoor or outdoor use and comes with a glass cover and a mounting plate.
Product Usage Instructions
- Find a clear area to work and unpack the fixture and glass from the carton.
- Review the instructions carefully before starting the assembly process
- Start the installation by removing the mounting plate (A) from the backplate (B). Remove the two screws (C) located at the top and bottom of the backplate (B) and set them aside for later use.
- Attach the mounting plate (A) to the junction box (J) using two screws (D) (not provided). Make sure that one of the holes (E) on the mounting plate is facing towards the ceiling before tightening the screws (D).
- Make all necessary electrical connections following the provided instruction sheet IS-18.
- After making all connections, tuck the wires into the junction box (J) and slip the backplate (B) over the mounting flange (E). Align the threaded holes in the flange (E) with the holes (H) in the backplate (B).
- Thread in the screws (C) that were removed earlier and tighten them to secure the fixture to the wall.
- Slide the glass (2) over the socket (1).
- Lock the glass with the socket ring (3).
- Install appropriate medium base bulbs in the lamp fixture.
- The fixture is now ready to be powered on.
Note: For wiring and grounding instructions, please refer to the provided IS-18 instruction sheet and any additional directions. It is important to turn off the power supply during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements. For indoor fixtures, connect the positive supply wire (A) to the positive fixture lead (B) using an appropriately sized twist-on connector. Connect the negative supply wire (C) to the negative fixture lead (D). For outdoor fixtures, follow the same steps as indoor fixtures but also cover the open ends of the connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall to prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
Assembly Instructions
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
DRAWING 1 – MOUNTING
-
To begin installation of your fixture it will first be necessary to remove the mounting plate (A) from the backplate (B). This is accomplished by first removing the two screws (C), located at the top and bottom of the backplate (B). Set screws in a safe place for use later.
-
Next attach mounting plate (A) to junction box (J) with two screws(D), NOT PROVIDED.
NOTE: make sure when installing mounting plate (A) that one of the holes (E) is facing toward the ceiling, before tightening screws (D) – see Drawing -
Make all necessary electrical connections following instruction sheet IS-18 provided.
-
After all connections are made, tuck wires into junction box (J) and slip backplate (B) over mounting flange (E) and align threaded holes, in flange (E), with holes (H) in backplate (B).
-
Thread in screws (C) removed earlier, and tighten to secure fixture to wall.
- Slide glass (2) over socket (1)
- Lock glass with socket ring (3)
- Lamp fixture with appropriate medium base bulbs
- Fixture can now be powered on
I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting
strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two
mounting screws in strap. Any remaining tapped hole may be used for the ground
screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under
the head of the ground screw (S) on fixture mounting strap (M) and connect to
the loose end of the fixture ground wire directly to the ground wire of the
building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtur es
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.
References