BEGA 24437K4 Wall Washer Light Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
Technical amendments reserved
Wall washer
24 437
Instruction Manual
24437K4 Wall Washer Light
Instructions for use
Application
Wall washer with symmetrical light distribution for the illumination of
façades and wall surfaces with the mounting surface being the reflection
surface.
The luminaire can be installed with the light distribution opening upwards or
downwards.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Clear safety glass
Reflector made of pure anodised aluminium 2 elongated fixing holes
Width 5.6 mm · 185 x 215 mm spacing 2 screw cable glands with strain relief
for through-wiring power connecting cable ø 7–12 mm 1 screw cable gland closed
at the factory with a dummy plug
Connecting terminal 2.5◽ with plug connection
Earth conductor connection
BEGA Ultimate Driver®
LED power supply unit
220-240 V ≂ 0/50-60 Hz
DC 176-264 V
DALI-controllable
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK04
Protection against mechanical impacts < 0.5 joule
– Safety mark
****– Conformity mark
Weight: 3.8 kg
This product contains light sources of energy efficiency class(es) C
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Lamp
Module connected wattage | 29.1 W |
---|---|
Luminaire connected wattage | 32.5 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 55 °C |
24 437 K3
Module designation | LED-1068/830 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 5640 lm |
Luminaire luminous flux | 4882 lm |
Luminaire luminous efficiency | 150,2 lm / W |
24 437 K4
Module designation | LED-1068/840 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 5800 lm |
Luminaire luminous flux | 5025 lm |
Luminaire luminous efficiency | 154,6 lm / W |
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Undo hexagon socket head screws (wrench size 3 mm) through the opening in the
luminaire housing up to the stop and lift luminaire top.
Lead the mains supply cable through the screw cable gland into the luminaire
back housing.
Ensure correct directionality towards the area to be illuminated.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
The installed black gasket insert is intended for cables ø < 10 mm.
For cables ø 10-12 mm the enclosed grey gasket insert must be used.
In case of through-wiring replace the factory installed dummy plug with the
enclosed corresponding gasket insert.At the same time, use the enclosed synthetic
cone-thrust collar between gasket insert and thrust screw (wrench size 22 mm)
(see sketch).
Tighten screw cable gland.
Make the earth conductor connection and the electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire.
Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctly.
Install the luminaire top, press-on and tighten screws evenly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Trim frame graphite with glass | 25 000 033 |
---|---|
Trim frame white with glass | 25 000 034 |
Trim frame silver with glass | 25 000 035 |
LED power supply unit | DEV-0270/700i |
LED module 3000 K | LED-1068/830 |
LED module 4000 K | LED-1068/840 |
Reflector | 76 001 920 |
Gasket | 83 001 983 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60
· 58689 Menden
· info@bega.com
· www.bega.com
References