BEGA 50604.1 Indoor Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 50604.1 Indoor Wall Luminaire Instruction Manual
Indoor Wall Luminaire

Wall luminaire for indoor use

Dimensions

Instructions for use

Application
Wall luminaire · indoor luminaire with integrated power supply unit for many lighting tasks in interior applications. The light emits upwards and downwards.

Product description

Luminaire made of aluminium alloy Finish Colour velvet white Safety glass Reflectors made of anodised pure aluminium 2 elongated fixing holes Width 5mm · 76,5mm spacing 1 cable entry for mains supply cable up to ø 10.5 mm max. 5 x 1.5@ Connecting terminal 2.5@ with plug connection Earth conductor connection 2-pole connection terminals for digital control LED power supply unit 220-240 V x 0/50-60 Hz DC 170-280 V DALI-controllable Basic insulation is provided between the mains and control cables BEGA Thermal Switch® Temporary thermal shutdown to protect temperature-sensitive components Safety class I Impact strength IK07 Protection against mechanical impacts < 2 joule r – Safety mark c – Conformity mark Weight: 2.6 kg This product contains light sources of energy efficiency class(es) E

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp
Module connected wattage 23 W
Luminaire connected wattage 26.3 W
Rated temperature ta=25 °C
Ambient temperature ta max=35 °C

50 604.1K3
Module designation 2x LED-0800/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 3470 lm
Luminaire luminous flux 2520 lm
Luminaire luminous efficiency 95,8 lm/W

50 604.1K4
Module designation 2x LED-0800/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 3520 lm
Luminaire luminous flux 2556 lm
Luminaire luminous efficiency 97,2 lm/W

Light technique
Wide beam rotationally symmetrical light distribution Half beam angle 41°

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Undo set screw and lift off luminaire housing. Loosen push plug connection and earth connection (plug connection). Pass the power connecting cable through the cable entry in the mounting plate. Note position of application of the mounting plate “arrow down”. Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface. Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection to terminal (plug connection).The two connecting terminals marked DA, DA are provided for digital control purposes. If these terminals are not assigned, the luminaire will work with full light output. Make earth conductor connection between luminaire housing and mounting plate. Push plug into coupler as far as it will go. Install luminaire housing over mounting plate and tighten set screw. Note position of application of the luminaire “arrow down”.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Defective glass must be replaced. Close the luminaire.

Spares
Glass/Trim ring 20 000 088M
LED power supply unit DEV-0365/700
LED module 3000 K LED-0800/930
LED module 4000 K LED-0800/940
Reflector 76 001 800M

BEGA Gantenbrink-Leuchten KG ·
Postfach 3160 · 58689 Menden ·
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals