BEGA 50 711.2 Recessed Ceiling Luminaire for Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA 50 711.2 Recessed Ceiling Luminaire for Indoor Use

DIMENSION

BEGA-50-711.2-Recessed-Ceiling-Luminaire-for-Indoor-Use-
FIG-1

Instructions for use

Application
Recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminum alloy housing. For installation into ceilings with a shallow depth in interior areas.

Product Description
Recessed ceiling luminaire »ACCENT«Die-cast aluminum housing Crystal glass, partially satin matt inside Reflector of anodised pure aluminium Ceiling frame ring made of stainless steel Recessed opening ø 68 mm Required installation depth 60 mm Fixing is achieved by using 2 adjustable wedge-shaped claws 2-pole connecting terminal for digital control External LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V DALI controllable A basic isolation exists between power cable and control line Safety class II 2 r – Safety mark c  – Conformity mark Weight: 0.4 kg This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 8.5 W
  • Luminaire connected wattage 10.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

50 711.2 K27

  • Module designation LED-0923/927
  • Colour temperature 2700 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1155 lm
  • Luminaire luminous flux 581 lm
  • Luminaire luminous efficiency 55,3 lm / W

50 711.2 K3

  • Module designation LED-0923/930
  • Color temperature 3000 K
  • Color rendering index CRI > 90
  • Module luminous flux 1200 lm
  • Luminaire luminous flux 604 lm
  • Luminaire luminous efficiency 57,5 lm / W

Installation

Luminaire housing must not be installed in heat-insulating material. LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. The recessed opening will be covered by the frame of the luminaire. Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.

Installation into false ceilings
A recessed opening of ø 68 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm (see sketch). The claws catch the panel from the reverse side. If the minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. The maximum thickness of the panel must be no more than 20 mm. Remove cover of the external LED power supply unit. Loosen set screws of cable strain relief. Tightening zone for strain relief: max. Ø 12mm. Connecting terminals for mains supply: max. 2,5@. Terminal DALI: max. 1,5@. Strip the wires 6 mm. Lead mains supply cable through the cable strain relief and fix set screws. Make an electrical connection. The connection of the control cables is achieved by means of both leads marked with – DALI. In case these leads are not used the luminaire will be operated at full light output.

Close case cover of the external LED power supply unit and press it until it is locked. Push external LED-power supply unit and luminaire housing into ceiling cut-out. Luminaire housing and external LED power supply unit must not be installed in heat-insulating material. Hand-tight screws of claw fasteners evenly. Lead enclosed ceiling frame ring over the screw-neck of the glass and push it down the gasket. Make sure that gasket is positioned correctly. Insert glass with mounted reflector and frame ring by turning it clockwise into luminaire housing.

Cleaning  Maintenance

Clean the luminaire regularly with solvent-free cleansers from dirt. The defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect from main supply. Unscrew the glass with the ceiling frame ring from the luminaire housing by turning it counter- clockwise. Please follow the installation instructions for the LED module. Check gasket. Screw in glass with ceiling frame ring by turning it clockwise beyond the stop. Defective glass must be replaced.

Spares

  • Spare glass 11 003 006 410 RG
  • LED power supply unit DEV-0434/250i
  • LED module 2700 K LED-0923/927
  • LED module 3000 K LED-0923/930
  • Trim ring 72 009 562 L
  • Reflector 76 001 209

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com