Chiyang Scent A305S Scent Diffuser Machine User Manual

June 12, 2024
Chiyang Scent

Chiyang Scent A305S Scent Diffuser Machine

Product Information

Product Name: A305S/M/L
Model Number: 50301-00001B1.0CYG-00117-B10-A305
Product Manual: SCENT MARKETING

Product Usage Instructions

  1. To download the APP, please search “scent marketing” in Google Play or App Store.
  2. To add a device, follow these steps:
    • Enter the password.
    • Set the device name and location.
  3. To delete a working period, use the time switch function.
  4. To set the time and date, use the time setting function.
  5. To turn on/off the fan, press and hold the corresponding button for 3 seconds.
  6. The button will be locked automatically if there is no further manual manipulation within 60 seconds. Press the SET button for about 5 seconds to unlock.
  7. To adjust the concentration grade, use the touch buttons to increase or decrease the grade.
  8. To amend the password, press the reset button to restore the factory settings (password: 8888).
  9. To set the working time period, follow these steps:
    • Select the working period (1-5).
    • Choose ON or OFF for the selected period.
    • Adjust the operation time and grade.
    • Repeat the steps for other days.
    • Confirm and exit the settings.
  10. Note: Customized grade settings can only be done through the APP.
  11. Ensure that the start working period is not the same as the stop working time to avoid machine malfunction.

Concentration and Consumption

Chiyang Scent-A305S-Scent-Diffuser-Machine-16

Up grade Down grade

Notice:

  1. Above date is base on test trial.
  2. Consumption data is for reference only. Different fragrance may be coming with different consumption.

APP instructions

Where can I download this APP:
Please search “scent marketing” in Google play or App store.

Chiyang Scent-A305S-Scent-Diffuser-Machine-1

Amend password

Chiyang Scent-A305S-Scent-Diffuser-Machine-2

If you forget the password, please press the reset button to restore the factory settings. The factory settings password is 8888.

Time setting

Chiyang Scent-A305S-Scent-Diffuser-Machine-3

Power on/off
Connect power supply, power on with a sound “beep”, and the screen displays initial time and current grade. The screen will be off when disconnect the power.

Fan on/off
Touch ▲ button (3s) to turn on fan, touch ▼ button (3s) to turn off fan.

Auto-lock and un-lock
Button will be locked automatically if there is no any further manual manipulation in 60s; Touch SET (about 5s) comes out with sound “beep” and screen lights on to unlock machine.

Local time setting
Touch SET button (about 3s) till a sound “beep” comes out for day setting; touch▲or▼to adjust the day; touch ENT button for local time setting, touch▲ or▼to adjust the time (Figure 1)

Concentration grade setting
There are 20 grades available. Touch▲to increase grade, touch ▼to decrease grade(Figure 2).

Work time period setting

  • There are 5 working periods available to be set every day (Figure 3).
  • Touch SET button to set working period (ON1) , touch ▲or▼ to choose working period (1-5); touch ENT button for the working period switch, touch ▲or▼ to choose ON or OFF, touch ENT button again to move to the operation time, touch ▲or▼to adjust number.
  • Touch ENT again for grade. Next touch ENT to choose the day (MON), touch ▲ button to turn on the working period (ON1) (Figure4), touch ▼ button to turn off the working period (OFF1) (Figure5).
  • Touch ENT to move to the next day and repeat the steps for TUES to SUN.
  • Once finish, touch SET to confirm and exit, Repeat the same setting steps of ON1 for ON2, ON3 ON4 and ON5.
  • PS:Grade display with “-Cu-“ is for customized grade set by APP only(Figure6).
  • Machine doesn’t work when the start working period is as same as stop working time

Working time period| 00:00

00-00

:

| 00:00

00-00

:

| 00:00

00-00

:

| 00:00

00-00

:

| 00:00

00-00

:

---|---|---|---|---|---
Mon| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Thues| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Wed| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Thur| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Fri| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Sat| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Sun| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF

(PS: The first working period is factory defaults with start working time 07:00 and stop working time 19:00,Grade1, the rest are all with 00:00.)

Specification

  • Product Name : Aroma diffuser
  • Model : A305S/ A305M/ A305L
  • Coverage : 200m /2 600m3 400m2/1200m3 800m /2 2400m3
  • Dimension : 295222112.5mm
  • Bottle: 850ml
  • Weight: 2.05kg 2.45kg
  • Power : 6W /6W / 9W
  • Voltage: DC12V

Chiyang Scent-A305S-Scent-Diffuser-Machine-9

Usage of sealing tape

  1. Before replacing atomizing core, wrap sealing tape around atomized core thread about 3-5 turns to avoid air leakage;
  2. Before connecting atomized connector, wrap sealing tape around atomized connector thread about 3-5 turns to avoid air leakage.

Installation

The method of using expansion bolts

Chiyang Scent-A305S-Scent-Diffuser-Machine-10

Drill the wall, insert the expansion tube into the hole, put the screw into the expansion tube and tighten it

Installation steps

Chiyang Scent-A305S-Scent-Diffuser-Machine-11

  1. Aim at the position of the mounting bracket, then drill the hole in the wall and insert the expansion bolts into the hole in the wall;
  2. Install the mounting bracket on the wall with screws, and finally hang the machine on the mounting bracket.

Overview

Chiyang Scent-A305S-Scent-Diffuser-Machine-12

Instruction

  1. Open the door by key
  2. Unscrew the atomized nozzle, take out the bottle
  3. Twist the bottle and fill essential oil
  4. Put atomized head to bottle and screw the atomized nozzle
  5. Finish time setting and lock machine

Chiyang Scent-A305S-Scent-Diffuser-Machine-13

Direction

Idea for Hotels, Conference rooms, Malls, Exhibition halls, Major retailers, Bars, SPAs, Business places or anywhere you wanto a fragrance experience.

Chiyang Scent-A305S-Scent-Diffuser-Machine-14

Caution

  • Shall not modify, disassemble or repair the machine arbitrarily. Any failure happens, please contact technician in time.
  • Shall not damage the power cord, force to bend, yank, heavy load, clip or reprocess.
    • Shall not use damaged plug or unmatched with the socket;
    • Shall not wet the machine or the plug;
    • Shall not use overloaded power socket, wire or broken plug.
  • Shall not touch the wire or product shell when thundering or/and lightening.
  • Shall not disassemble the machine when it is under operating.

Warning

  1. Please keep the machine vertical. Tilt or lie flatly may cause oil over flow. Themachine efficiency may be affected.
  2. Shall not modify, disassemble or repair the machine if you are not a technician. If any failure happens to the machine, please contact our technical personnel.
  3. The machine is stop during off work time period, even the Atomization display is on
  4. The button is invalid and no display on screen when machine locked
  5. If the display is cluttered, freezes or other problem, please restart machine to reset to defaults(Method: Press ENT button and hold on about 5 seconds till hear a sound “beep”)

Troubleshooting

Before asking to have the machine repaired, please try to diagnose the problem first following to below instructions.

Chiyang Scent-A305S-Scent-Diffuser-Machine-17

Equipment cleaning
The machine needs to be cleaned when below situations happen:

  1. You’re about to change to another kind of essential oil.
  2. The atomization volume becomes weak.

Cleaning steps:

  1. Pull out the atomized head, loose the bottle.
  2. Find a larger container and fill the industrial alcohol up, then soak the atomized head and the bottle for 5-10mins.
  3. Airing the atomized head and the bottle.

FCC Warning

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

NOTE

  1. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
    reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
    accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

NOTE
Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirement.

CE Caution
Use the product in the environment with the temperature between -10℃ and 50℃;
Otherwise, it may damage your phone. It can be operated under 2000m. For the following equipment:
Product Name: Aroma diffuser
Model: A305
Guangzhou Chiyang Scent Technology Co., LTD. hereby declares that this [Name: Aroma diffuser, Model: A305] is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.

This product can be used across EU member states.

CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Do not use other unauthorized chargers power supply for charging.
Do not use the product in environment below -10℃ or above 50℃ for charging.