Product Overview

Product Parameters

Dimension :  25517589
Bottle capacity :  180ml
Coverage :  100㎡
Material :  Glass/430 stainless steel/ PP/POM/PET/Aluminium alloy
Power :  1880g
N.W.: :  5.5W
Input voltage :  DC12V

APP operation

Where to get the app:
Please search “scent marketing” on Google play or the App store.
Note:

  1. Please make sure that the Bluetooth function is turned on;
  2. Please make sure that the location function of the mobile phone is turned on.

Change Password

Select the working time or stop time of atomization by sliding up or down, the stop time is 60 seconds and cannot be adjusted.
After changing the password, if you still forget it, please press the Reset button to restore the factory setting, the default password is 8888.

Working Periods Setting

Turn on the power
Connect the power and turn on the switch with the sound“Beep” coming out, Then the screen shows the initial time and the current grade.
Turn off the power
The screen will be off then turn off the switch and disconnect the power.

Fan control
Long press and hold for 3 seconds to turn on the fan, then long press and hold for 3 seconds to turn off the fan.
Screen lock or unlock
Screen lock: If there is no operation in the 60s, the screen will be locked automatically.
Unlock: Tap the SET button and hold for 3 seconds, the screen will be unlocked, and the screen is it up.
Current time setting

  1. Tap the SET button and hold for 3 seconds until the “beep” sound comes out, you can start to set the working periods.
  2. Tap▲or▼to select the current working day, then tap ENT to start to set the current time, Tap▲or▼to adjust the current time, then tap SET to save the setting.
    (show as picture 1)

Concentration Grade setting
There are 9 grades available. Tap▲the button to increase the scent concentration.(2)
Tap▼, to decrease the scent concentration.(Shown as picture2)

Working periods setting

  1. There are total 5 working periods available(shown as pictur
  2. Tap SET to start setting the first working period, and the working time will be flashing on the screen.
  3. Tap▲or▼adjust the working time, then confirm by tapping ENT.
  4. Tap ENT can turn to the next setting(order: the switch of the current working periods→ start/stop working time →grades→working day→the next working period), then you can tap▲or▼adjust the current setting.. (show as picture 5).
    The start working time can not be the same as the stop working time, otherwise, these working periods will not be displayed on APP.

Day| 00:00
00:00| 00:00
00:00| 00:00
00:00| 00:00
00:00| 00:00
00:00
---|---|---|---|---|---
Mon| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Tue| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Wed| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Thu| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Fri| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Sat| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF
Sun| ON/OFF| ON/OFF| ON/OFF| ON/OFF| ON/OFF

(PS: The first working period is factory defaults with start working time 07:00 and stop working time 19:00, others are all with 00:00.)

Operation Step


1. Open the machine with the key, and don’t remove the key| 2, Pull out the atomizer head
3. Take out the bottle, and fill it with essential oil, then tightly close the head.| 4 . Place the bottle back into the machine, after aligning with the position, press downward the atomizer head.
5. Adjust the working periods, the lock the machine with the key.

Grades and Consumption

Grades Working time(s) Stop time(s) Consumption(g/h)
G1 3S 60S 0.067g/h
G2 7S 60S 0.171g/h
G3 11S 60S 0.257g/h
G4 15S 60S 0.386g/h
G5 19S 60S 0.449g/h
G6 23S 60S 0.532g/h
G7 27S 60S 0.606g/h
G8 31S 60S 0.706g/h
G9 35S 60S 0.716g/h
      Customized Working3~60s,stop60s

▲Increase the grade ▼Decrease the grade
Note: The data shown above is only for reference, and it is normal for the consumption to fluctuate by 15%.

installation Guide

Drill holes in the wall, and insert the wall anchors into the hole, then secure the bracket with screws.

installation Step

  1. Position the bracket holes, then drill holes on the wall, then insert the wall anchors into the wall holes.,
  2. Secure the bracket with screws on the wall, and align it with the holes of the machine on the bottom, then secure the machine with screws from the bottom.

Warning

To avoid fire or electric shock, please do not damage, forced to bend, yank or heavy load,
To avoid electric shock, short circuit, fire or other -When the power cable is damaged or isn’t -Do not wet the machine or the plug; -Shall not use the overloaded power socket or plug.
To avoid electric shock, please do not touch cut or reprocess the power cable. damages. match with the electrical outlet, please do not use an AC power plug. the broken plug. the wire and the machine thundering or/and. lightening.
To avoid any problems, please do not disassemble the machine when the machine is working.

Cautions

  1. Please always keep the machine upright, tilting or placing it flat will cause oil leakage, which will lead to machine damage.
  2. Shall not modify, disassemble or repair the machine arbitrarily. If any failure happens, please contact our relevant technicians in time.
  3. The machine will not work when it is not in the working period, even the atomization icon is displayed on the screen.
  4. When the screen is in lock status, the button cannot be operated and there is no display on the screen.
  5. If the display is garbled, breakdown or has other problems, please restart the machine.
    Restore factory setting
    (Step: Tap the ENT button and hold about 5 seconds until the “beep” sound comes out.)

Troubleshooting

Before asking for after-sale service, please try to handle the following problems based on the solutions.

it|
---|---
Problems| Solutions
Do not diffuse| -To check whether the machine switch is turned on.
– The air pump may be damaged, please replace a new one. -The air tube on the atomizer head may be loose, please tighten
Weak mist| -The atomized core may be blocked, please clean it with alcohol or replace a new one.
-To check whether the gasket is damaged or loose, please replace a new one.
-To check whether the tube is loose or not, please tighten it.
Oil sprinkle| -To check the machine is tilted or laid down, please keep the machine upright.
Oil leakage| -The bottle cap may be loose, please secure the cap. -The gasket of the atomizer head is damaged or missed.
Abnormal noise| -The air pump may be loose, please tighten it. -The air pump may be damaged, please replace it with a new one.

FCC STATEMENT :

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and
(2)This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the  user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.
European agent: MEGASYSTEMS
address: 55 Amfitheas Avenue 75 64 Paleo Faliro, Αthens
https://megasystems.gr/diffusion-technologies/?lang=en

Product name: Aroma diffuser
Product model: A311
Manufacturer: Guangzhou Chiyang Scent Technology Co., LTD.
Address: 4F, Building C5, Gaosha Industrial Estate, Zhongyi Village, Zhongcun Town, Panyu Guangzhou, Guangdong, 511495 China
Frequency Range: 2402-2480MHZ
Max. output Power: 0.12dbm
SIMPLIFIED EU DECLARATION OF CONFORMITY
The simplified EU declaration of conformity referred to in Article 10(9) shall be provided as follows:
Hereby, Guangzhou Chiyang Scent Technology Co., LTD. declares that the radio equipment type Aroma diffuser(A311) is in compliance with Directive 2014/53/EU, and this product is allowed to be used in all EU member states.
The full text of the EU declaration of conformity is available at the following This product can be used across EU member states.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals