Chiyang Scent A501 Aroma Diffuser Instruction Manual
- June 15, 2024
- Chiyang Scent
Table of Contents
PRODUCT MANUAL
Aroma diffuser
A501 Aroma Diffuser
lf the QR code cannot be scanned, please search for “Scent Marketing” in Google play or APP store.
https://play.google.com/store/apps/details?id=com.IAA360.ChengHao| https://itunes.apple.com/cn/app/scent-marketing/id1243308763?mt=8
Specification
[Model] | A501 |
---|---|
[Size] | 23624077mm |
[Bottle] | 500mI |
[Input] | DC 12V . 0.3A MAX |
[Power] | 3W |
[Coverage] | 50n4/150m3/5300ft₃ |
[N.W.] | 2.2 kg |
[Material] | plastic, acrylic |
Bluetooth instruction
Where to get the app:
Please search for “scent marketing”in Google play or App store.
Note:
- Please make sure that the Bluetooth function is turned on;
- please make sure that the location function of the mobile phone isturned on.
Amend password
lf you forget the password, please press the reset button to restore the factory setting.The factory settings password is 8888.
Installation step
-
Insert the key, twirl anticlockwise to unlock the door.
-
Tightly connect the atomizer head and the fragrance bottle, and install them to the machine.
-
Install the batteries according to the positive and negative terminals.
Note: 1. When the unit is connected by DC 12V adapter, the batteries stop supplying power, disconnect the DC 12V connection, the batteries start to supplying power
2. After installing new batteries, the unit will work after 25s. -
nsert the key and twirl clockwise to lock the door.
Bluetooth indicator:
As usual, the bluetooth indicator is powered off. After connectingsuccessfully
and it will be flashing for reminder.
Battery indicator:
When it lights for 30s stands for full charged, 5s flashing stands for low
power and when it always lights, this machine will stop working.
Concentration and Consumption
Grade | Work time(s) | Stop time(s) | Consumption(g/h) |
---|---|---|---|
G1 | 3s | 900s | 0.08 |
G2 | 3s | 810s | 0.09 |
G3 | 3s | 720s | 0.1 |
G4 | 3s | 630s | 0.11 |
G5 | 3s | 540s | 0.12 |
G6 | 3s | 450s | 0.22 |
G7 | 3s | 360s | 0.31 |
G8 | 3s | 270s | 0.41 |
G9 | 3s | 180s | 0.5 |
G10 | 3s | 90s | 0.6 |
Notes:
- 500ml oils can diffuse 11000-12500 times under normal circumstances;
- Allof the above grade atomization work time is 3 seconds;
- Different grade and oil may with different consumption.
Warning
- Please keep the machine vertical. Tilt orlie flatly may cause oil overflow. The machine efficiency may be affected.
- Shall not modify , disassemble or repair the machine. lf any failure happens to the machine, please contact our technical personnel.
Troubleshooting
Before asking to have the machine repaired, please try to diagnose the problemfirst following to bellow instructions.
Breakdown | Solution |
---|---|
Does not diffuse | – Check whether the batteries are loose or in low battery |
situation
– lithe machine is in “not working period”, it stops diffuse.
– Check whether the air pump is normal or not.
– Check whether the gasket is damaged/loose or not.
Spray little| – Check whether the gasket is damaged;
– Check whether the atomized core is plugged or not;
– Check whether the cap of the atomized head is loose or.
Oil spill| – Whether the atomized head is damaged or not.
Abnormal sound| – Pump is loose, install it correctly;
– The pump is damaged , change a new one.
Equipment cleaning
The machine needs to be cleaned when below situations happen:
- You’re about to change to another kind of essential oil;
- The atomization volume becomes weak.
Cleaning steps:
- Pullout the atomized head, loose the bottle.
- Find a larger container and fill the industrial alcohol up, then soak the atomized head and the bottle for 5-10mins.
- Airing the atomized head and the bottle.
Note:
- After cleaning the device, turn on the unit, press and hold SET button for 3 seconds to reset remaining oil level;
- After spaying 3 seconds, the unit will stop 2 seconds, then it will spray 50 milliseconds for clearing the remaining oil in the atomizer head, itis normal.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician tor help.
Caution: Any changes or modifications to this device not explicitly approved
by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
RF Exposure Information
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.