Chiyang Scent A501 Aroma Diffuser Instruction Manual

June 15, 2024
Chiyang Scent

Chiyang Scent lOGO PRODUCT MANUAL
Aroma diffuser

A501 Aroma Diffuser

lf the QR code cannot be scanned, please search for “Scent Marketing”  in Google play or APP store.


https://play.google.com/store/apps/details?id=com.IAA360.ChengHao| https://itunes.apple.com/cn/app/scent-marketing/id1243308763?mt=8

 Specification

[Model] A501
[Size] 23624077mm
[Bottle] 500mI
[Input] DC 12V . 0.3A MAX
[Power] 3W
[Coverage] 50n4/150m3/5300ft₃
[N.W.] 2.2 kg
[Material] plastic, acrylic

Chiyang Scent A501 Aroma Diffuser - Specification

Bluetooth instruction

Where to get the app:
Please search for “scent marketing”in Google play or App store.
Note:

  1. Please make sure that the Bluetooth function is turned on;
  2. please make sure that the location function of the mobile phone isturned on.

Chiyang Scent A501 Aroma Diffuser - Bluetooth
instruction

Amend password

Chiyang Scent A501 Aroma Diffuser - Amen password

lf you forget the password, please press the reset button to restore the factory setting.The factory settings password is 8888.

Installation step

Chiyang Scent A501 Aroma Diffuser - Installatin step

  1. Insert the key, twirl anticlockwise to unlock the door.

  2. Tightly connect the atomizer head and the fragrance bottle, and install them to the machine.

  3. Install the batteries according to the positive and negative terminals.
    Note: 1. When the unit is connected by DC 12V adapter, the batteries stop supplying power, disconnect the DC 12V connection, the batteries start to supplying power
    2. After installing new batteries, the unit will work after 25s.

  4. nsert the key and twirl clockwise to lock the door.

Chiyang Scent A501 Aroma Diffuser - clockwise Bluetooth indicator:
As usual, the bluetooth indicator is powered off. After connectingsuccessfully and it will be flashing for reminder.
Battery indicator:
When it lights for 30s stands for full charged, 5s flashing stands for low power and when it always lights, this machine will stop working.

Concentration and Consumption

Grade Work time(s) Stop time(s) Consumption(g/h)
G1 3s 900s 0.08
G2 3s 810s 0.09
G3 3s 720s 0.1
G4 3s 630s 0.11
G5 3s 540s 0.12
G6 3s 450s 0.22
G7 3s 360s 0.31
G8 3s 270s 0.41
G9 3s 180s 0.5
G10 3s 90s 0.6

Notes:

  1. 500ml oils can diffuse 11000-12500 times under normal circumstances;
  2.  Allof the above grade atomization work time is 3 seconds;
  3. Different grade and oil may with different consumption.

Warning

  1. Please keep the machine vertical. Tilt orlie flatly may cause oil overflow. The machine efficiency may be affected.
  2. Shall not modify , disassemble or repair the machine. lf any failure happens to the machine, please contact our technical personnel.

Troubleshooting

Before asking to have the machine repaired, please try to diagnose the problemfirst following to bellow instructions.

Breakdown Solution
Does not diffuse – Check whether the batteries are loose or in low battery

situation
– lithe machine is in “not working period”, it stops diffuse.
– Check whether the air pump is normal or not.
– Check whether the gasket is damaged/loose or not.
Spray little| – Check whether the gasket is damaged;
– Check whether the atomized core is plugged or not;
– Check whether the cap of the atomized head is loose or.
Oil spill| – Whether the atomized head is damaged or not.
Abnormal sound| – Pump is loose, install it correctly;
– The pump is damaged , change a new one.

Equipment cleaning

The machine needs to be cleaned when below situations happen:

  1. You’re about to change to another kind of essential oil;
  2. The atomization volume becomes weak.

Cleaning steps:

  1. Pullout the atomized head, loose the bottle.
  2. Find a larger container and fill the industrial alcohol up, then soak the atomized head and the bottle for 5-10mins.
  3. Airing the atomized head and the bottle.

Note:

  1. After cleaning the device, turn on the unit, press and hold SET button for 3 seconds to reset remaining oil level;
  2. After spaying 3 seconds, the unit will stop 2 seconds, then it will spray 50 milliseconds for clearing the remaining oil in the atomizer head, itis normal.

FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician tor help.

Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RF Exposure Information
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.Chiyang Scent
lOGO

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals