SKYDANCE DALI DT-B AC Triac Dimmer Owner’s Manual
- June 12, 2024
- SKYDANCE
Table of Contents
SKYDANCE DALI DT-B AC Triac Dimmer
Model No.: DT-B
Features
- AC phase-cut mosfet DALI dimmer
- One DALI address
- One channel output
- Trailing edge dimmer
- Adjustable minimum brightness
- Compliant with DALI standard protocol 101, 102, 205 (IEC 62386)
- Compatible with DALI products from other international incorporation
- DALI address can be automatically assigned by DALI master
- Over-heat protection and overload protection with automatic recovery
Technical Parameters
Input and Output | Input voltage | Output voltage | Output current | Output power |
---|---|---|---|---|
Input | 100-240VAC | 100-240VAC | Max 1.5A | 150-360W |
Compatible Load Types
Load Type | Maximum Load |
---|---|
Dimmable LED lamps | 200W @ 220V, 100W @ 110V |
Triac Dimmable LED drivers | 200W @ 220V, 100W @ 110V |
Incandescent lighting | 400W @ 220V |
HV Halogen lamps | 200W @ 110V |
Remarks: Due to the variety of LED lamp designs, the maximum number of LED lamps is further dependent on the power factor result when connected to the dimmer. The maximum permitted number of drivers is 200W divided by driver nameplate power rating, and make sure the surge current is no more than 2 times 65A.
Mechanical Structures and Installations
Operation: DALI address assigned by DALI masters. DALI address can also be assigned by DALI Master controller automatically. Please refer to user manuals of compatible DALI Masters for specific operations.
Safety & Warnings
Ensure proper installation and follow safety guidelines provided in the user
manual.
User Manual Ver 1.0.0
Features
- AC phase-cut mosfet DALI dimmer, one DALI address, one channel output.
- Trailing edge dimmer.
- The minimum brightness is adjustable.
- In accordance with DALI standard protocol 101, 102, 205 (IEC 62386) and in compliance with DALI products from other international incorporation.
- DALI address can be automatically assigned by DALI master.
- To dim and switch single color dimmable LED lamps, traditional incandescent and halogen lights.
- Over-heat protection, Overload protection, recover automatically.
Technical Parameters
Input and Output
Input voltage| 100-240VAC
Output voltage| 100-240VAC
Output current| Max 1.5A
Output power| 150-360W
Package
Size| L75x W75 x H40mm
Gross weight| 0.981kg
Warranty
Warranty| 5 years
Compatible Load Types
Load Type | Maximum Load | Remarks |
---|---|---|
Dimmable LED lamps | 200W @ 220V |
100W @ 110V
| Due to variety of LED lamp designs, maximum number of LED lamps
is further dependent on power factor result when connected to dimmer.
Triac Dimmable LED drivers| 200W @ 220V
100W @ 110V
| Maximum permitted number of drivers is 200W divided by driver nameplate
power rating, and make sure the surge current is no more than 2 times 65A.
Incandescent lighting, HV Halogen lamps| 400W @ 220V
200W @ 110V
|
Mechanical Structures and Installations
Wiring Diagram
Caution:
Please carefully ensure all wire connections and polarities are correct and
secure before applying power, otherwise, this controller will be damaged.
Note: When calculating the maximum number of load lamps or drivers, the input
power or input current parameters of a single lamp or driver must be used, the
output power parameters can not be used.
In addition, the maximum surge current of the dimmer is 65A, the sum of surge
current of multiple dimmable LED drivers should not exceed 2 times. otherwise,
the product will be overloaded and damaged.
Operation
Minimum brightness setting
The minimum brightness of the device can be set or deleted by pressing the
“SET” button on the dimmer.
-
Recall minimum brightness:
Short press the “SET ” button on the dimmer, LED indicator ash one, the light output the minimum brightness. -
Setting minimum brightness:
Adjust the brightness to a desired minimum level, then press and hold down the “SET ” button 2s until the LED indicator Flash one, the current brightness is set as the minimum brightness.
The light can only be dimmable between this minimum brightness and maximum brightness. -
Delete minimum brightness:
Adjust the brightness to the maximum level, then press and hold down the “SET ” button 2s until the LED indicator flash one, the minimum brightness setting is deleted.
DALI address assigned by DALI masters
DALI address can also be assigned by DALI Master controller automatically.
Please refer to user manuals of compatible DALI Masters for speci?c
operations.
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>