Oase Filtral UVC 700/1200 All-in-One Pump Filter and UV Light Instruction Manual
- June 6, 2024
- Oase
Table of Contents
- Oase Filtral UVC 700/1200 All-in-One Pump Filter and UV Light Instruction
- Information about these operating instructions
- Installation
- Start-up (Filtral UVC 700 / 1200)
- Maintenance and cleaning
- UVC lamp replacement
- Storage/Winterization
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Oase Filtral UVC 700/1200 All-in-One Pump Filter and UV Light Instruction
Manual
Filtral UVC 700 / 1200
REMINDER
CALL 1-866-627-3435
BEFORE RETURNING TO STORE
Information about these operating instructions
Welcome to OASE Living Water. You made a great choice with the purchase of this product Filtral UVC 700/1200. Prior to operating the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance with these instructions. Please strictly follow the enclosed instructions to ensure safe and correct handling of the product. Keep these instructions in a safe place. Please also hand over the instructions when passing the unit on to a new owner.
WARNINGS AND CAUTIONS SYMBOLS
Symbols used in these instructions
The symbols used in this operating manual have the following meanings:
Risk of injury to persons due to dangerous electrical voltage.
This symbol indicates an imminent danger, which can lead to death or severe
injuries if the appropriate measures are not taken.
Risk of personal injury caused by a general source of danger. This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.
****Important information for trouble-free operation.
Intended use
Filtral UVC 700/1200, referred to in the following as “unit”, may only be used
as specified in the following:
- For cleaning garden ponds.
- For operation with clean water.
- Operation under observance of the technical data.
The UVC lamp installed in the unit is intended to kill algae and bacteria in the pond water. Even in small doses, its radiation is harmful for eyes and skin. Never use the UVC lamp in a defective housing or outside the housing, or any other purpose other than that intended.
The following restrictions apply to the unit:
- Do not use in swimming pools.
- Never use the unit to convey fluids other than water.
- Never run the unit without water.
- Do not use for commercial or industrial purposes.
- Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
Use other than that intended
This unit can be dangerous and cause harm if not used in accordance with these
instructions. Any use not in accordance with these instructions or
modification(s) to the unit will void the limited warranty.
Installation
Filtral UVC 700
Important:
-
The unit can be used with the following:
○ With the nozzle set to create various fountain displays.
○ With the branch valve, allowing an additional water feature to be operated simultaneously with the fountain nozzle. -
It is recommened to place the unit horizontally on the ground ensuring its stable position.
-
Do not lift the unit by its power cord.
-
The unit’s filter foam, biomedia, UVC and pump are preinstalled in the filter housing.
If NOT using the nozzle set
- Screw the branch valve (D) on the connection thread of the UVC water housing (A) using the washer (B). Close the upper outlet using the cover cap (C).
- Connect tubing for water features to the lateral separately regulated connection of the branch valve.
NOTE: Tubing is NOT INCLUDED.
● Connect the other end of the tubing to desired water feature or spitter.
For installation using the nozzle set
- Assemble the connection element for the ball joint (A) into the branch valve (B).
- Slide the clamping screw (D) down the tube and screw on to the connection element for the ball joint (A) to secure the tube.
- Screw in the nozzle mounting (E). Select a nozzle insert to use (F). The fountain height and shape depend on the nozzle insert used.
- Screw the assembly on the connection thread of the UVC water housing (G) using the washer (H).
- If desired, connect tubing for additional water features to the lateral separately regulated connection of the branch valve.
NOTE: Tubing is NOT INCLUDED.
● Connect the other end of the tubing to desired water feature or spitter
Questions, problems, missing parts?
Before returning to your retailer, call us at
1-866-627-3435, 8 a.m.-6 p.m., EST,
Monday-Friday, or email us at customercare@oase-
livingwater.com. Or visit our
website at www.oase-livingwater.com
Filtral UVC 1200
Important:
-
The unit can be used with the following:
○ With the nozzle set to create various fountain displays.
○ With the branch valve, allowing an additional water feature to be operated simultaneously with the fountain nozzle.
○ With an air pump to enrich the water with additional oxygen -
It is recommened to place the unit horizontally on the ground ensuring its stable position.
-
Do not lift the unit by its power cord.
-
The unit’s filter foam, biomedia, UVC and pump are preinstalled in the filter housing.
Filtral UVC 1200
Filtral UVC 700 / 1200
Start-up (Filtral UVC 700 / 1200)
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
- Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the water.
- Isolate the unit before starting any work.
- Secure the unit to prevent unintentional switching on.
Grounding instructions
This appliance must be grounded. In the event of a malfunction or breakdown,
grounding will reduce the risk of electric shock by providing a path of least
resistance for electric current. This appliance is equipped with a cord having
an appliance-grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is installed and grounded in
accordance with all local codes and ordinances.
Warning
Improper connection of the appliance-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or service
representative if you are in doubt whether the appliance is properly grounded.
Do not modify the plug provided with the appliance; if it will not fit the
outlet, have a proper outlet installed by a qualified technician.
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Switching on: Connect the unit to the mains.
The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
- The indicator lamp (A) indicates the ON/OFF status of the UVC lamp.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
- Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the water.
- Isolate the unit before starting any work.
- Secure the unit to prevent unintentional switching on.
CAUTION
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.
- Never operate the UVC lamp outside its casing.
- Never operate the UVC lamp in a casing that is defective.
Danger: Ultraviolet radiation.
Do not expose eyes to lamp rays.
Disconnect power before servicing or replacing lamp.
Replace lamp only with lamp rated 7 watts (UVC 700) 9 watts (UVC 1200):
Warning: To reduce the risk of electric shock – Connect only to a circuit
that is protected by a ground-fault circuit interrupter (GFCI )
For indoor and outdoor household use
Opening the filter housing and cleaning the different filters
Cleaning the pump
Filtral UVC 700 / 1200
- Unscrew the pump (A) from the UVC water housing (B). Remove the pump and place the UVC water housing to the side.
- Unscrew the pump lid (C) by turning counterclockwise (bayonet closure) and remove rotor (D).
- Clean all pump components using clean water and a brush. After cleaning the pump, reassemble the pump in the reverse order.
● If you intend on cleaning the UVC water housing do not screw the pump back into the housing.
Opening and cleaning the UVC water housing
Filtral UVC 700 / 1200
NOTE
For safety reasons, the UVC lamp can only be switched on when the unit head has been correctly fitted into the casing
● The UVC water housing (A) is fastened to the unit head (B) by means of a bayonet closure.
- Press on the engagement lug (C) at the unit head (B), turn the UVC water housing (A) counter-clockwise and carefully pull it off the unit head (B).
- Clean the UVC water housing (A) under running water. Check the quartz glass for damage and clean its outer face with a moist cloth.
Closing the UVC water housing
Filtral UVC 700 / 1200
**NOTE**
For an optimum filter performance, we recommend to replace the UVC lamp after
approx. 8000 operating hours.
See section Replace UVC lamp before reassembling the unit.
UVC lamp replacement
Filtral UVC 700 / 1200
Attention! Breakable glass.
Possible consequences: Injury to your hands caused by cuts
Protective measures: Handle the quartz glass and UVC lamp with care..
CAUTION
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.
- Never operate the UVC lamp outside its casing.
- Never operate the UVC lamp in a casing that is defective.
Danger: Ultraviolet radiation.
Do not expose eyes to lamp rays.
Disconnect power before servicing or replacing lamp.
Replace lamp only with lamp rated 7 watts (UVC 700) 9 watts (UVC 1200):
Warning: To reduce the risk of electric shock – Connect only to a circuit
that is protected by a ground-fault circuit interrupter (GFCI)
For indoor and outdoor household use
Storage/Winterization
- Put the unit out of operation at water temperatures below 32 °F (0 °C) or, at the latest, when freezing temperatures are to be expected.
- Thoroughly clean the unit, check for damage.
- Store immersed in water or filled with water in a frost-free place. Do not immerse the power plug in water!
- Ensure that the storage place is inaccessible to children.
Wear parts
The UVC lamp, the different filters and the rotor are wear parts and are
excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand
by cutting off the cables. Further information about the recycling of this
product can be obtained from your local municipal authority. Only dispose of
the UVC lamp by using the system provided from your local municipal authority.
Troubleshooting
OASE North America INC. · www.oase-livingwater.com
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>