Cyber Power P0820SUF0-FR Surge Protector User Manual

June 4, 2024
CyberPower

Cyber Power P0820SUF0-FR Surge Protector

Cyber Power P0820SUF0-FR Surge Protector

SPECIFICATIONS

  • ISCCR = 1500 A
  • Type of LV systems: TN system
  • Circuit breaker: 10 A
  • One-port SPD
  •  Operating humidity: 5 % to 95 %
  • Ambient air temperature: 0 °C – 25 °C
  • IPE = 150 uA
  • Modes of protection: Uoc=6 kV, Up=1.2 kV (L-N, L-PE, N-PE)
  • Power cord: 1.8 M

Installation:

Power Connections

  1. The surge protector must be plugged into a properly grounded outlet.
  2. Plug all connected equipment directly into the surge protector.

Important Safety Instructions:

DO NOT connect to an ungrounded outlet. DO NOT use with 2-wire extension cords or adapters. This surge protector is designed for indoor use only. Install the surge protector away from heat emitting appliances such as radiators or heat generators. Do not install where excessive moisture is present.
Never install electrical or telephone wiring during a lightning storm.
DO NOT USE FOR MEDICAL, LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES.

Mounting the Surge Protector
You can mount the surge protector to a vertical surface with just two screws (not included), using the eye loops provided at the backside of the Protector.

CAUTION:

RISK OF ELECTRIC SHOCK – USE ONLY IN DRY LOCATIONS AND ONLY INDOORS. DO NOT PLUG INTO ANOTHER SURGE PROTECTOR, POWER STRIP, EXTENSION CORD OR OTHER RELOCATABLE POWER TAP.
Indicator Lights
Protected LED Indicator
Illuminated when the surge protection feature is working properly.
Grounded LED Indicator
Illuminated when the surge protector is properly grounded.

Troubleshooting

If the Protected indicator does not light, the surge protector’s AC line is no longer protected from surges. Replace the surge protector. The surge protector may have received a power surge or spike beyond its specified limits that might overload the protection circuitry and make it inactive. The surge protector absorbed enough of the surge to protect your connected equipment, but it will not protect against future surges and spikes. If the grounded indicator does not light when you plug in the surge protector, move the surge protector to a different grounded three-prong AC outlet. If it still does not light, return the product to the retailer for assistance. If the surge protector appears to be working properly, your outlets may not be properly grounded and need to be repaired by a professional electrician. If the grounded indicator turns off after a period of use, the surge protection has been depleted. Replace your surge protector.

Warranty

CyberPower warrants this product to be free from defect in electrical parts or manufacture for two (2) years. If a defect results in product failure during its normal use within the warranty period, please contact your local dealers and/or distributors for warranty services.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CyberPower User Manuals

Related Manuals