V-ZUG V6000 45M PowerSteam CombiSteamer Instruction Manual

June 12, 2024
V-ZUG

V ZUG Logo 1220092-02
23041, 23047

Installation instructions
CombiSteamer V6000 45M, all devices

Safety precautions

Electrical connections must be carried out by competent personnel according to the rules and standards for low voltage installations and according to the requirements of the local electric utility. An appliance supplied ready with a plug must be connected only to an earthed wall socket properly installed according to regulations. For domestic electrical installation, an all-pole mains disconnect device with 3 mm contact gaps must be installed. Switches, plug connections, MCBs and safety fuses that are freely accessible after installation of the appliance and that switch all poles are regarded as permissible isolating devices. Proper earthing and separately routed neutral and protective conductors provide for a safe and trouble-free operation. After completion of the installation, it must not be possible to touch live parts or cables with operational insulation. Check existing installations. Check rating plate for required supply voltage, type of current and fuse protection. Electrical connection using H05VV-F (Td) or CH-N1VV-U (TT) cable or H07V-U (T) installation wires in an insulating sleeve. The connection cable should measure at least 150 cm from the point where it comes out of the wall.

**** Always wear gloves when handling unpacked appliances. Do not lift appliance by the operating panel or the door handle. Do not indent sides or top of appliance and do not tip over appliance. The niche and gap dimensions given below must be observed to ensure proper ventilation. If used at an altitude of over 2,000 metres, a reduced performance must be expected. Only service personnel is permitted to modify the appliance (incl. inlet and outlet lines and mains cable).

Observe all local regulations. For installation in inflammable materials, observe the rules and standards for fire protection.

Installed in tall unit

V ZUG V6000 45M PowerSteam CombiSteamer - Installed

Mains cable without plug

V ZUG V6000 45M PowerSteam CombiSteamer - cable| V ZUG V6000 45M PowerSteam CombiSteamer - cable 2
---|---
Above oven/steamer| Below oven/steamer| Above warming drawer
---|---|---
| |

The appliance must be installed in a de-energized state

Check perpendicularity of niche.
Check appliance/fasteners
Check connected loads
For installation, connected loads must correspond
Place appliance in front of the niche
Connect cable
** Connect cable to connecting terminals in accordance with connection plate
Mains cable connection with 25 A fuse protection:**
– Connect appliance according to connection plate (230 V~ 16/25 A)
– Note code on label, complete installation and start appliance
– Select service settings and enter service code
– Activate 25 A mains connection and enter code from connection plate
Push completely in and align appliance
Secure appliance to niche

Frontal for 60 cm wide appliance
Carry out function and safety checks
Demo mode switched off? If not, switch off in service menu with password 6301.

V ZUG Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

V-ZUG User Manuals

Related Manuals