CyberPower SL700U Slim Battery Backup Ups User Manual

June 1, 2024
CyberPower

cyberpower-logo

CyberPower SL700U Slim Battery Backup Ups

FEATURES

CyberPower-SL700U-Slim-Battery-Backup-Ups-FIG-1

  1. Power On Switch
  2. Power On Indicator (green)
  3. Battery and Surge Protected Outlets
  4. Full-Time Surge Protection Outlets
  5. USB Charging Ports
  6. Circuit Breaker
  7. USB Port to PC
  8. Wiring Fault Indicator (red)
  9. Widely-Spaced Outlets

PRODUCT REGISTRATION

Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed power protection, operation, and performance during the lifetime of the product. Please take a few minutes to register your product at: www.CyberPowerSystems.com/registration. Registration certifies your product’s warranty, confirms your ownership in the event of a product loss or theft, and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership.

IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

  • CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity-controlled indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range).
  • CAUTION! To reduce the risk of electric shock, do not remove the cover. There are no user-serviceable parts inside.
  • CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
  • CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the unit.
  • CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component.
  • CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection by the National Electric Code, ANSI/NFPA 70.
  • CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer / Data Processing Equipment, ANSI/NFPA 75.
  • CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
  • CAUTION! Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!

  • CyberPower Systems does not sell products for life support or medical applications.
  • DO NOT use in any circumstance that would affect operation and safety of life support equipment, any medical applications or patient care.
  • DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock,  do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.

DO NOT USE THE UPS ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.

INSTALLING YOUR UPS SYSTEM

UNPACKING
Inspect the UPS upon receipt. The box should contain the following:

  • (a) UPS unit
  • (b) User’s manual
  • (c) USB device cable

DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

  1. Ensure that the equipment plugged into the outlet does not exceed the UPS unit’s rated capacity (700VA/370W for SL700U, 750VA/375W for SL750U, 900VA/450W for SL900UC). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
  2. Many factors can affect the amount of power that your electronic equipment will require. For optimal system performance keep the load below 80% of the unit’s rated capacity.

HARDWARE INSTALLATION GUIDE

  1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the battery’s maximum charge capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or turned off.
  2. With the UPS unit turned off and unplugged, connect your equipment requiring battery backup into the battery power supplied outlets. Plug the other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or another large electrical device into the “Battery and Surge Protected Outlets”. The power demands of these devices will overload and possibly damage the unit.CyberPower-SL700U-Slim-Battery-Backup-Ups-FIG-2
  3. Plug the UPS into a 2-pole, 3-wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc…). The warranty prohibits the use of extension cords, outlet strips, and surge strips.
  4. Press the power switch to turn the unit on. The Power On indicator light will illuminate green and the unit will “beep” twice.
  5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
  6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
  7. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three months to ensure optimal battery life.
  8. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
  9. Lay the UPS horizontally or use the key-hole mounting slots to affix the UPS to the wall in the proper orientation.

BASIC OPERATION

  1. Power On Switch
    To turn the UPS on, press the power button for approximately 2 seconds – you will hear a constant tone (1 second) – and release after a short beep. To turn the UPS off, press the power button for approximately 2 seconds – you will hear a constant tone (1 second) – and release after two short beeps. Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button twice. The default setting is for the Alarm On. To turn the Alarm Off, quickly press the power button twice. You will hear two short beeps when the Alarm is turned off. To turn the Alarm back ON, quickly press the power button twice. You will hear a single short beep when the Alarm is turned on.

    • When the Alarm is turned off, there will be no audible notification when the UPS reaches a low battery state.
  2. Power On Indicator (green)
    This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.

  3. Battery and Surge Protected Outlets
    The unit has five battery-powered and surge-protected outlets to ensure temporary uninterrupted operation of your equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical device into the “Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly damage the unit.)

  4. Full-Time Surge Protection Outlets
    The unit has three surge suppression outlets.

  5. USB Charging Ports
    SL750U/SL700U: Two USB-A ports, 5V 2.4A power output SL900UC: One USB-A port (5V 2.4A), one USB-C port (5V 18W)

  6. Circuit Breaker
    Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.

  7. USB Port to PC
    The port allows connection and communication between the USB port on the computer and the UPS unit. The UPS communicates its status to the PowerPanel® Personal software.

  8. Wiring Fault Indicator (red)
    This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The UPS will not provide surge protection without being plugged into a grounded and properly wired wall outlet.

  9. Widely-Spaced Outlets
    The UPS unit has two widely-spaced outlets, so AC power adapters can be plugged into the UPS without overlapping or blocking adjacent outlets.

TROUBLESHOOTING

Problem Possible Cause Solution

Full-time surge protection outlets stop providing power to equipment. The circuit breaker button is projecting from the side of the unit.

| ****

**** The circuit breaker has been tripped due to an overload.

| ****

Turn the UPS off and unplug at least one piece of equipment. Reset the circuit breaker by pressing the button, and then turn the UPS on.

The UPS does not perform the expected runtime.| ****


The battery not fully charged.

| ****

Recharge the battery by leaving the UPS plugged in.



Battery is worn out.

| ****

Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support.












The UPS will not turn on.

| ****

The on/off switch is designed to prevent damage from rapidly turning it off and on.

| ****

Turn the UPS off. Wait 10 seconds and then turn the UPS on.


The unit is not connected to an AC outlet.

| ****

The unit must be connected to a 110/120V 50/60Hz outlet.



The battery is worn out.

| ****

Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support.



Mechanical problem.

| ****

Contact CyberPower Systems at: cyberpowersystems.com/support.



The frequency is beyond 47-63Hz

| ****

Turn the UPS off. Make sure the frequency range is within 47-63Hz.

Or you can turn on with battery mode.







PowerPanel® Personal is inactive (all icons are gray).

| ****


The USB cable is not connected.

| ****

Connect the USB cable to the UPS unit and an open USB port on the back of the computer.


The USB cable is connected to a bad USB port.

| ****

Check for a different USB port and plug the cable in.



The unit is not providing battery power.

| ****

Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit.

DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS

CyberPower-SL700U-Slim-Battery-Backup-Ups-FIG-3

  • LED will flash when UPS alarm is beeping.

SYSTEM FUNCTION BLOCK DIAGRAM

CyberPower-SL700U-Slim-Battery-Backup-Ups-FIG-4

TECHNICAL SPECIFICATIONS

Model SL700U SL750U SL900UC

Capacity

| ****

700VA / 370W

| ****

750VA / 375W

| ****

900VA / 450W


Nominal Input Voltage

| ****

120 Vac


Input Frequency

| ****

50/60 Hz +/- 3 Hz

On-Battery Output Voltage| ****

120Vac +/- 5%

On-Battery Output Frequency| ****

50Hz/60Hz +/- 1% (auto-sensing)

Max. Load for UPS Outlets| ****

700VA / 370W

| ****

750VA / 375W

| ****

900VA / 450W

Max. Load for Full-Time Surge Protection outlets| ****

12 Amps

On-Battery Output Wave Form| ****

Simulated Sine Wave


Operating Temperature

| ****

+ 32°F to 104°F / 0°C to 40°C

Operating Relative Humidity| ****

0 to 95% non-condensing

Size Width/Height/Depth| ****

12.76 x 5.4 x 2.76 in. / 324 x 138 x 70 mm


Net Weight (lbs./kg)

| ****

6.78 lbs. / 3.07 kg

Typical Battery Recharge Time| ****

8 hours typical from total discharge


Typical Battery Life

| ****

3 to 6 years, depending on the number of discharge/recharge cycles


Recommended Battery

| ****

Sealed Maintenance Free Lead Acid Battery


Safety Approvals

| ****

UL1778(UPS), cUL CSA C22.2 No. 107.3-05, FCC/DoC Class B

CYBERPOWER GREENPOWER UPS™ TECHNOLOGY

Advanced Energy-Saving Design
The GreenPower UPS™ has a high-efficiency charger, which makes it the most energy-efficient UPS in its class. The advanced high-frequency charging system significantly improves charging efficiency and conserves energy. As a result of this advanced design, the GreenPower UPS™ uses less energy compared to competitive models. The GreenPower UPS™ is manufactured by the Restriction on Hazardous Substances (RoHS) directive making it one of the most environmentally-friendly UPS systems on the market today.

FCC COMPLIANCE STATEMENT

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Canadian Compliance Statement
CAN ICES-3 (B)/NMB-3(B)

LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE

Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee.

Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty. For further information please feel free to contact CyberPower at: Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379; call us at 877-297-6937; or submit a web ticket online at cyberpowersystems.com/support. Cyber Power Systems (USA), Inc. encourages environmentally sound methods for the disposal and recycling of its UPS products. Please dispose of and/or recycle your UPS and batteries in accordance to the local regulations of your state.

WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov. © 2023 CyberPower Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber Power Systems(USA) Inc. All rights reserved. All other trademarks are the property of their respective owners.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals