CyberPower B602RC5 6 Outlet Surge Protector User Manual

October 30, 2023
CyberPower

cyberpower-logo

CyberPower B602RC5 6 Outlet Surge Protector

CyberPower-B602RC5-6-Outlet-Surge-Protector-PRODUCT

Product Information

The Cyber Power Systems 6 Outlet Surge Protector (Model Number: B602RC5) is a power strip that provides surge protection for up to six standard grounded electrical devices. It has a 2.5 ft power cord and a 15 amp circuit breaker that can be reset if tripped due to an overload. The surge protection feature can handle up to 500 joules of energy to protect connected devices from power surges and spikes. The product also has an ON/OFF reset control switch and a protected LED indicator that illuminates when the surge protection feature is working correctly.

This product is designed for indoor use only and comes with a warning that it contains chemicals known to the State of California to cause cancer and reproductive harm.

Product Usage Instructions

  1. Ensure that the product is placed on a stable, flat surface and that the power cord is not damaged or frayed.
  2. Connect up to six standard grounded electrical devices to the surge protector’s outlets.
  3. Turn on power to all outlets by flipping the ON/OFF reset control switch to the ON position.
  4. If the 15 amp circuit breaker trips due to an overload, turn off all connected devices and unplug the device that caused the overload. Then, flip the ON/OFF reset control switch to the OFF position and back to ON to reset the circuit breaker.
  5. To ensure that the surge protection feature is working correctly, check that the protected LED indicator is illuminated. If it is not illuminated, the surge protector may have been overloaded and will need to be replaced.

If you experience any issues or have questions about the product, contact Cyber Power Systems technical support at 1-877-297-6937 or visit CyberPowerSystems.com/support for more information.

FEATURES

CyberPower-B602RC5-6-Outlet-Surge-Protector-FIG-1

  1. ON/OFF Reset Control Switch and Circuit Breaker Controls power to all outlets. The switch is also a 15 A breaker. When an overload occurs, it will automatically switch off. To resume operation, ensure the overload condition is removed and reset the surge protector by switching the unit ON.
  2. Protected LED Indicator Illuminated when the surge protection feature is working properly.
  3. Standard Grounded Outlets (6)
  4. Power Cord

SPECIFICATIONS

  • Model Number: B602RC5
  • Outlets: Standard Grounded Outlets (6)
  • Power Cord Length: 2.5 ft
  • Surge Protection: 500 Joules
  • Electrical Rating: 125 V/15 A/60 Hz/1875 W
  • Circuit Breaker: Resettable 15 Amp

WARNING: This product can expose you to chemicals including Styrene, which are known to the State of California to cause cancer, and Bisphenol A (BPA), which are known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:

  • Use only in dry locations and only indoors.
  • DO NOT plug into another relocatable power tap.
  • DO NOT “daisy chain” surge protectors.
  • DO NOT use with any aquarium equipment.
  • DO NOT use if properly grounded outlets are not available.
  • DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and electrical service panel.
  • DO NOT use for medical or life support equipment. This device features internal protection that will disconnect the surge protective component at the end of its useful life, but it will maintain unprotected power to the load.

TROUBLESHOOTING

If the ON/OFF is switched OFF, the 15 Amp circuit breaker may have tripped. Examine your connected equipment and remove the device that is overloading the circuit. Then, turn the ON/OFF switch back to RESET. If the protected indicator does not light, the surge protector’s AC lines are no longer protected from surge. The surge protector may have received a power surge or spike beyond its specified limits that overloaded the protection circuitry and rendered it inactive. The surge protector has protected your connected equipment as designed, but it will not protect against future surges and spikes. It should be replaced.

FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:

  • Product information and certifications
  • Product Warranty
  • Connected equipment guarantee

TECHNICAL SUPPORT

  • Visit: CyberPowerSystems.com/support
  • Toll-Free: 1-877-297-6937
  • Hours of Operation: Monday – Friday: 7:00 am – 6:00 pm CST
  • © 2023 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners.

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 CyberPowerSystems.com

References