ICI T-CAM 380 Series Handheld Thermal Camera for Temperature Measurement User Guide

June 4, 2024
ICI

CAM 380 Series Handheld Thermal Camera for Temperature Measurement
User Guide

©Copyright 2021, Infrared Cameras, Inc. – All rights reserved. The contents of this document may not be reproduced in whole or in parts without the written consent of the copyright owner.
Printed in the United States of America.

2105 W. Cardinal Dr.
Beaumont, TX 77705
866-861-0788
www.infraredcameras.com

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION. THE  MANUFACTURER ALLOWS HIMSELF THE RIGHT TO MODIFY WITHOUT ANY PRELIMINARY OPINION THE TECHNICAL SPECIFICATIONS OF THE PRODUCT. THIS MANUAL MAY CONTAIN TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS.

NOTICE ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND. NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE ARE PROVIDED “AS IS” WITH ALL FAULTS. ICI DISCLAIMS ALL WARRANTIES,  EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR  TRADE PRACTICE.

THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT  SHIPPED WITH THE PRODUCT AND IS INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE  LICENSE OR LIMITED WARRANTY, CONTACT YOUR ICI REPRESENTATIVE FOR A COPY.

IN NO EVENT SHALL ICI BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING  OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF ICI HAS
BE ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

Package Includes

ICI T CAM 380 Series Handheld Thermal Camera for Temperature Measurement -
Package Includes

ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION

Set-Up

A.

ICI T CAM 380 Series Handheld Thermal Camera for Temperature Measurement -
Set Up

MAKE SURE TRIPODS DO NOT BLOCK THE DIRECT PATH OF THE PERSON(S) TO BE IMAGED TO ENSURE THE EQUIPMENT WILL NOT BE MOVED OR  KNOCKED DOWN. USING A DIVIDING BARRIER WILL HELP KEEP TRIPODS SEPARATE FROM THE PATH.

TURN ON THE CAMERA BY PRESSING AND HOLDING THE POWER BUTTON FOR AT LEAST TWO SECONDS.

PRESS AND HOLD THE POWER BUTTON FOR MORE THAN 5 SECONDS TO SHUT DOWN THE CAMERA.

THE THERMAL IMAGER NEEDS SUFFICIENT WARM-UP TIME FOR THE MOST ACCURATE TEMPERATURE MEASUREMENTS AND BEST IMAGE  QUALITY. THIS TIME CAN OFTEN VARY TO ENVIRONMENTAL CONDITIONS. IT IS BEST TO WAIT FOR A MINIMUM OF 10 MINUTES FOR THE DEVICE TO  COMPLETELY WARM UP.

Battery Installation

MAKE SURE TO HOLD THE CAMERA FIRMLY IN BOTH HANDS WHEN REMOVING OR REPLACING THE BATTERY OR ATTACHING OR REMOVING THE  BATTERY BAY COVER.

A.
Hold the camera firmly in both hands placing a thumb on the grip lines.

B.
Press the grip lines firmly to create a gap.

C.
Keep pressing the grip lines and pull battery cover up to remove it.

D.
Ensure metal contacts are aligned, then push the battery into the battery bay.

DO NOT FORCE THE BATTERY INTO THE BATTERY BAY. IF THE USER FEELS SIGNIFICANT RESISTANCE REMOVE THE BATTERY AND ENSURE METAL  CONTACTS ARE ALIGNED BEFORE TRYING TO PLACE THE BATTERY INTO THE BATTERY BAY.

MAKE SURE TO HOLD THE CAMERA FIRMLY IN BOTH HANDS WHEN REMOVING OR REPLACING THE BATTERY OR ATTACHING OR REMOVING THE  BATTERY BAY COVER.

E.
To replace a battery held in the battery bay push the battery buckle. The battery will be ejected.

F.
Pressing the grip lines, align the battery cover to the battery bay, and press the cover toward the device.

G.
Close gap by releasing the battery cover.

ENSURE THE BATTERY COVER IS PROPERLY ATTACHED. IMPROPER ATTACHMENT OF THE BATTERY COVER MAY EXPOSE THE BATTERY AND INTERNAL  ELECTRONICS TO ELEMENTAL DAMAGE.

Memory Card

A.
Insert the Micro-SD Card into the top of the device until a clicking sound is heard.

ICI T CAM 380 Series Handheld Thermal Camera for Temperature Measurement -
Memory Card

DO NOT FORCE THE MICRO-SD CARDS INTO THE SLOT. THE SIDE OF THE CARD WITH CONTACT PINS MUST BE INSERTED FIRST. IF THERE IS  RESISTANCE FLIP THE CARD AROUND AND TRY AGAIN. TO EJECT THE MEMORY CARD PRESS UNTIL A CLICK IS HEARD AND THEN RELEASE.  MEMORY CARDS WILL BE EJECTED.

Charging Instructions: Option 1

A.
While a battery is inside the device, plug the USB Type-C end of the USB cable into the top of the device.

B.
Plug the other end of the USB cable into an available USB port on a computer.

ICI T CAM 380 Series Handheld Thermal Camera for Temperature Measurement -
Charging

WHEN USING A COMPUTER FOR CHARGING THE COMPUTER SHOULD BE POWERED ON. CHARGE THE BATTERY FOR A MINIMUM OF 3 HOURS  BEFORE USING.

ICI DOES NOT RECOMMEND CHARGING THE DEVICE WHILE IT IS ON A TRIPOD. LAY THE DEVICE FACE DOWN ON A FLAT AND STABLE DESK OR  TABLE WHILE CHARGING.

ENSURE THE IMAGER IS NEAR ROOM TEMPERATURE BEFORE CHARGING THE DEVICE. DO NOT CHARGE IN EXTREMELY HOT OR COLD AREAS.  THE BATTERY CAPACITY MAY BE DECREASED IF CHARGED IN AN EXTREME TEMPERATURE ENVIRONMENT.

IF YOU DO NOT USE THE IMAGER FOR A LONG PERIOD OF TIME, PUT THE DEVICE IN A COOL AND DRY ENVIRONMENT. THE BATTERY WILL  DISCHARGE OVER TIME; THEREFORE, THE IMAGER SHOULD BE CHARGED OCCASIONALLY TO PREVENT DAMAGE TO THE BATTERY OR THE  DEVICE.

Charging Instructions: Option 2

REMOVE THE BATTERIES FROM THE DEVICE TO FOLLOW THIS METHOD OF CHARGING.

A.
Plug the USB Type-C end of the USB cable into the battery charger.

B.
Plug the other end of the USB cable the power adapter.

ICI T CAM 380 Series Handheld Thermal Camera for Temperature Measurement -
Charging 2

C.
Insert batteries into a battery charger.

D.
Plug the power adapter into a 110/120V electrical outlet.

WHEN THE BATTERY IS NOT PLACED IN THE CHARGER THE INDICATOR LIGHT FLASHES. THE LIGHT TURNS RED WHEN THE BATTERY IS  PLACED AND CHARGED. WHEN THE BATTERY IS FULLY CHARGED THE LIGHT TURNS GREEN.

About ICI / Contact

Infrared Cameras, Inc.
2105 W. Cardinal Dr.
Beaumont, TX 77705

Phone: 409-861-0788 | Toll Free: 866-861-0788 | International: 409-861-0788

General Inquiry: [email protected]
Website: www.infraredcameras.com

You may reach a representative by phone or email Mon – Fri 8:00 AM – 5:00 PM CST.
ICI manufactures complete systems and software. We can provide complete engineering, software, and OEM solutions. Our Fortune 500 clients rely on us for infrared equipment and thermography training (which we offer through the Infrared Training Institute).

In addition to providing custom germanium, silica, and sapphire optics, we also build windows for enclosures, as well as custom pan and tilt units. We can even provide customizable explosion-proof systems.

Our knowledge and experience stem from years of using infrared imaging and temperature measurement instruments to provide solutions to: managers, engineers, scientists,  inspectors, and operators in space, power companies, medical, pulp and paper, food industry, research, and development, and various process industries. You can see our products and services used in industrial, commercial, and government applications worldwide. Originally named Texas Infrared (still DBA), Infrared Cameras, Inc. has been in business since March 1995.

Thank you for your dedication and continued support.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ICI User Manuals

Related Manuals