Indu Sol B28-R GmbH Specialist in Industrial Networks User Guide
- June 12, 2024
- Indu-Sol
Table of Contents
- Indu-Sol GmbH Specialist in Industrial Networks
- PROmesh B28-R
- Quickstart User Guide
- Full-managed Industrial Ethernet Switches
- General Notes
- Device Connections
- Technical Data
- General Information
- Safety Instructions
- Scope of Delivery
- Mounting steps
- Disassembling the device
- Power Supply
- Configuring a Network Connection
- Accessing the Web User Interface
- Restore Factory Setting
- Interpreting LED Displays
- References
Indu-Sol GmbH Specialist in Industrial Networks
PROmesh B28-R
Quickstart User Guide
All accompanying materials of the product can be found at:
https://sdx.indu-sol.com/s/LxoL4DwQspDHY6Q
Full-managed Industrial Ethernet Switches
General Notes
! WARNING
Commissioning and operation of this device may be carried out by qualified personnel only. Qualified personnel are persons who are authorized to commission, ground and label devices, systems and circuits in accordance with the standards of safety engineering.
Something`s wrong with your product?
You can reach our technical support team on weekdays between 07:30 am 04:30
pm (CET) by telephone: +49(0)34491 / 581-14 or send us an e-mail: support
@indu-sol.com. We will get in touch with you promptly.
Your system is at a standstill?
Reach out to our emergency service even outside our regular opening hours:
+49(0)34491 / 580-0.
Version 1.0 | Date: 13.01.2023 | Product Code: 114110100
Printed in Germany
This document is subject to change without notice.
© Copyright 2023 Indu-Sol GmbH
Device Connections
-
16 x RJ45 Ports
8 x Combo Ports
4 x SFP Ports -
Status LEDs
Status | Error | PSU 1 | PSU 2 | Reset -
X 2 Power Supply and redundant alarm contact
PWR1 = 100-240 V AC
PWR2 = 100-240 V AC
= Grounding screw
Technical Data
Voltage Supply | 2 x 100 – 240 V AC |
---|---|
Full-Load power consumption | 37,8 W @ 220 VAC |
No-Load power consumption | 21,1 W @ 220 VAC |
Size (H x B x T) | 44 x 440,4 x 304,8 mm |
Weight | 3,94 kg |
Mounting | 19“ Rack Montage |
Protection Class | IP30 |
Storage temperature | -40°C .. 85°C |
Operating temperature | -40°C .. 75°C |
Relative Humidity | 5% .. 95% RHD nicht kondensierend |
Port Mirroring | Rx, Tx+Rx |
PROFINET Conformance Class | Class A |
Data Ports | 16 x 10/100/1000 Mbit/s RJ45 |
8 x 10/100/1000 Mbit/s Combo Ports
4 x 1 Gbit/s SFP Ports
Backplane Capacity| 56 Gbit
Throughput| 65,5 Mpps
Switch memory| 12 Mbit
MAC Adress Table| 16 K
Switching Mode| Store & Forward
Diagnose & Management| Port statistics
Port mirroring
Alarm management
MTBF| 49 years
General Information
The PROmesh B28-R is a full-managed Ethernet/PROFINET switch for industrial automation systems which can be easily and conveniently configured via a web UI. It enables uncomplicated installation of bus, star and ring structures with switching functionality.
Safety Instructions
Before putting the PROmesh B28-R into operation, check whether it is in perfect condition externally. Always observe the technical specifications of the device to ensure safe and optimal use. The PROmesh B28-R is designed for IP30 protection environments. Take appropriate measures to ensure proper operation of the unit in a different environment.
! WARNING
In case of suspected damage, please return the PROmesh B28-R immediately to your supplier and do not put it into operation.
Do not open the housing under any circumstances. Unauthorized opening of the housing will void any warranty claims.
The PROmesh B28-R is designed for use in PROFINET applications according to Conformance Class A.
For complete support of the PROFINET standards, please also observe the selection, layout and wiring of the data ports according to these standards.
Scope of Delivery
- PROmesh B28-R
- Quickstart User Guide (hardcopy)
- 2x power cable (AC)
- Serial port cable
- Rack mount lug x2
- Foot pad x4
Mounting steps
This product is suitable for rack mounting
Step 1:
Select the device mounting location to ensure enough space.
Step 2:
Adopt 4 bolts to install the mounting lugs in the device position as figure
below.
Step 3:
Place the device in the Rack; adopt 4 bolts to fix the two sides mounting lugs
in the rack.
Step 4:
Check and confirm the product is mounted firmly on the rack, mounting ends.
Disassembling the device
Step 1
Turn off the power of the device.
Step 2
Adopt screw driver to loosen the 4 bolts fixed on the mounting lugs in the
rack.
Step 3
Shift out the device from the rack, disassembling ends.
Power Supply
! WARNING
Do not mount the PROmesh B28-R directly next to devices that generate strong electromagnetic interference fields or constantly emit heat to their surroundings. Also protect the PROmesh B28-R from intense sunlight.
The PROmesh B28-R is provided with a redundant power supply. The connections are additionally secured with a power button. Connect the PROmesh B28-R to the power supply via the power supply adapter. Then switch on the device via the power switch.
! NOTE
First, plug the power supply terminal block into the power supply connector of the device. Then plug the power supply terminal block.
Power switch:”-” means power ON, ,,O” means power OFF.
If the external power supply is correctly connected and activated, all status LEDs of the PROmesh B28-R will light up briefly. After a short initialization phase the LEDs go out and the device is ready for operation and can now be configured in the network.
Configuring a Network Connection
Download the Service Tool to your client PC (Windows). You can find the
software at the following link:
www.indu-sol.com/en/servicetool
! NOTE
Our software is updated regularly. Please, make sure you are using the latest version.
Connect the PC to a suitable data line on one of the data ports (P1 - 28).
The PROmesh B28-R and the client PC must be located in the same IP address range and IP subnet. For this you have to assign a corresponding IP address to your PROmesh B28-R for the first time. Use the already installed ServiceTool.
After assigning a suitable IP address and subnet mask, the Web UI of the PROmesh B28-R can be reached.
The PROmesh B28-R is delivered with the following factory settings:
IP Address | 192.168.1.254 |
---|---|
Subnet mask | 255.255.255.0 |
Gateway | 0.0.0.0 |
User name | admin123 |
Password | admin123 |
After successful installation and start of the software, you can scan the system with the search setting PROmesh B28. The PROmesh B28-R is displayed in the search result. You can then make and save individual entries in the input mask.
! NOTE
Make sure that the IP address you selected has not yet been assigned. If required, you can display IP addresses that have already been assigned using the PROscan® Active V2 license software from Indu-Sol.
! WARNING
When logging in for the first time, you must change the factory-set password. It is your responsibility to document this password and protect it against unauthorized access
Accessing the Web User Interface
The device-specific functions of the PROmesh B28-R can be configured via an integrated Web-UI. Open your browser, enter the IP address of the PROmesh B28-R configured in the ServiceTool in your browser bar or use the above configuration data. Alternatively, you can right-click on the corresponding list entry in the context menu of the ServiceTool to select ,,to website”. The Web UI now opens in your standard browser.
! NOTE
Further information on the configuration options and troubleshooting can be
found at the following link:
www.indu-sol.com/en/manual-promesh
Restore Factory Setting
RESET is restoring default settings button. Device Restoring default settings steps as follows: press and hold the RESET button, power on the device again, wait for about 3~4 seconds to restore the factory settings.
Interpreting LED Displays
LED label | Mode | Meaning |
---|---|---|
PWR1 | On | Voltage at terminal sufficient |
Off | Voltage at terminal insufficient | |
PWR2 | On | Voltage at terminal sufficient |
Off | Voltage at terminal insufficient | |
Status | On | The system is not operating normally |
Flashing | The system is working correctly | |
Off | The system does not start correctly | |
Alert | On | There is an alarm (power supply or port connection) |
Off | There is no error. | |
Port Status | On | The port has established a valid network connection |
Flashing | The port is in network communication exchange | |
Off | The port has not established a valid network connection |
Indu-Sol GmbH
Blumenstraße 3
04626 Schmoelln
Germany
Telephone: +49 (0) 34491 580-0
Telefax: +49 (0) 34491 580-499
info@indu-sol.com
www.indu-sol.com
Certified according to DIN EN ISO 9001:2015
All accompanying materials of the product can be found at: https://sdx.indu- sol.com/s/LxoL4DwQspDHY6Q
References
- Sol.com | Welcome
- Indu-Sol | Feldbusse & industrielle Netzwerke optimieren
- Indu-Sol - Manual Download
- Download Center: Software & Firmware - Indu-Sol
- Downloadcenter: Benutzerhandbücher - Indu-Sol
- Downloadcenter: Software & Firmware - Indu-Sol
- SDX
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>