Indu-Sol PROmesh B16 Industrial Ethernet Switches User Guide

June 12, 2024
Indu-Sol

Indu-Sol logo Indu-Sol GmbH –Specialist in Industrial Networks
PROmesh B16
Quickstart User Guide
Industrial Ethernet Switches

Device Connections

Indu-Sol PROmesh B16 Industrial Ethernet Switches - fig
1

Technical Data

Voltage Supply 2x 24 VDC
Max. Current Consumption 0,8 A
Max. Power Consumption 8W
Size (H x W x D) 138 x 53 x 110 mm
Weight 800 g
Mounting 35 mm DIN rail
Protection Class IP20
Storage temperature -10°C … 60°C
Operating temperature -10°C … 60°C
Relative Humidity 5% .. 95%, RHD non-condensing
PROFINET Conformance Class B
PROFINET standard PROFINET 2.4
Port Mirroring Rx, Tx+Rx
PROFINET Netload Class Class III
Data Ports 16x 10/100 MBit/s RJ45
Switching Mode Store & Forward
Diagnosis & Management Network load monitoring

Port-Mirroring
DCP, I&M
SNMPv1, v2c, v3

General Information

The PROmesh B16 is a full-managed Ethernet/PROFINET switch for industrial automation systems which can be easily and conveniently configured via a web UI. It enables uncomplicated installation of bus, star and ring structures with switching functionality.

Safety Instructions

Before putting the PROmesh B16 into operation, check whether it is in perfect condi- tion externally. Always observe the technical specifications of the device to ensure safe and optimal use. The PROmesh B16 is designed for IP30 protection environments. Take
appropriate measures to ensure proper operation of the unit in a different environment.
! WARNING
In case of suspected damage, please return the PROmesh B16 immediately to your supplier and do not put it into operation.
Do not open the housing under any circumstances. Unauthorized opening of the housing will void any warranty claims.
The PROmesh B16 is designed for use in PROFINET applications according to Conformance Class B.
For complete support of the PROFINET standards, please also observe the selection, layout and wiring of the data ports according to these standards.

Scope of Delivery

  • PROmesh B16
  • 7-pole 5 mm terminal block (power supply and alarm contact)
  • Quickstart User Guide (hardcopy)

Mounting on the DIN Rail

Mount the PROmesh B16 upright in the switch cabinet on a 35 mm DIN rail (DIN EN 60715).
! WARNING
Do not mount the PROmesh B16 directly next to devices that generate strong electromagnetic interference fields or constantly emit heat to their surroundings. Also protect the PROmesh B16 from intense sunlight.

Power Supply

The PROmesh B16 is operated with a redundant DC voltage of 24 VDC, Connect a suitable power source to the labeled terminals of the 7-pin 2,5 mm2 terminal block. Connect the positive lead to one of the VDC contacts and the ammunition lead to the corres-ponding GND contact.
If the external power supply is correctly connected and activated, all status LEDs of the PROmesh B16 will light up briefly. After a short initialization phase the LEDs go out and the device is ready for operation and can now be configured in the network.

Configuring a Network Connection

Download the Service Tool to your client PC (Windows). You can find the software at the following link: https://sdx.indu-sol.com/s/EBcg2Qn8yG8KZFf
! NOTE:
Our software is updated regularly. Please, make sure you are using the latest version.
Connect the PC to a suitable data line on one of the data ports (P1 – 16).
The PROmesh B16 and the client PC must be located in the same IP address range and IP subnet. For this you have to assign a corresponding IP address to your PROmesh B16 for the first time. Use the already installed ServiceTool.
After assigning a suitable IP address and subnet mask, the Web UI of the PROmesh B16 can be reached.
The PROmesh B16 is delivered with the following factory settings:

IP Adress 0.0.0.0
Subnet mask 0.0.0.0
Gateway 0.0.0.0
Username admin
Password admin

After successful installation and start of the software, you can scan the system with the search setting PROFINET-Gerät. The PROmesh B16 is displayed in the search result. You can then make and save individual entries in the input mask.
! NOTE: Make sure that the IP address you selected has not yet been assigned. If required, you can display IP addresses that have already been assigned using the PROscan® Active V2 license software from Indu-Sol.
! WARNING:
When logging in for the first time, you must change the factory-set password. It is your responsibility to document this password and protect it against unauthorized access

Accessing the Web User Interface

The device-specific functions of the PROmesh B16 can be configured via an integrated Web-UI. Open your browser, enter the IP address of the PROmesh B16 configured in the ServiceTool in your browser bar or use the above configuration data. Alternatively,  you can right-click on the corresponding list entry in the context menu of the ServiceTool to select „to website“. The Web UI now opens in your standard browser.
! NOTE:
Further information on the configuration options and troubleshooting can be found at the following link: https://sdx.indu-sol.com/s/EBcg2Qn8yG8KZFf

Interpreting LED Displays

LED label Mode Meaning
VDC1 Green Voltage at terminal sufficient
Off Voltage at terminal insufficient
VDC2 Green Voltage at terminal sufficient
Off Voltage at terminal insufficient
Status Green Active connection to the PROFINET controller
Yellow No active connection to the PROFINET controller
Error Red Power failure, port error or configured alarm active
Off No power failure, no port error and no configured alarm active
Port Status On The port has established a valid network connection
Flashing The port is in network communication exchange
Off The port has not established a valid network connection

Indu-Sol GmbH
Blumenstraße 3
04626 Schmoelln
Germany
Telephone: +49 (0) 34491 580-0
Telefax: +49 (0) 34491 580-499
[email protected]
www.indu-sol.com
Certified according to DIN EN ISO 9001:2015 All accompanying materials of the product can be found at: https://sdx.indu-sol.com/s/EBcg2Qn8yG8KZFf

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Indu-Sol User Manuals

Related Manuals