Indu-Sol PROmesh P9+ 9 Port Industrial Managed Switch
User Manual and Quickstart Guide
The PROmesh P9+ is a full-managed industrial Ethernet switch designed for PROFINET networks. It has 9 data ports with 10/100/1000 MBit/s RJ45 connectors, and supports PROFINET 2.4 standards. The device is protected by Class B and Class III protection classes.
Technical Specifications
- Voltage Supply : 2x 24 VDC
- Max. Current Consumption : 0.8A
- Max. Power Consumption : 8W
- Size (H x W x D): Not specified
- Weight : Not specified
- Mounting: Hutschiene DIN EN 60715
- Protection Class : Class B and Class III
- Storage Temperature: Not specified
- Operating Temperature : Not specified
- Relative Humidity : Not specified
- PROFINET Conformance : PROFINET 2.4 Rx, Tx+Rx
- PROFINET Standard : Class III
- Data Ports : 9x RJ45 with 10/100/1000MBit/s speed
- Diagnosis & Management Online wire monitoring Leakage current monitoring Network load monitoring Port-Mirroring DCP, I&M SNMPv1, v2c, v3 SD Card
The PROmesh P9+ is a full-managed Ethernet/PROFINET switch for industrial automation systems which can be easily and conveniently configured via a web UI. It enables uncomplicated installation of bus, star and ring structures with switching functionality
Product Usage Instructions
Mounting the PROmesh P9+
To mount the PROmesh P9+, follow these steps:
- Mount the device vertically on a horizontal Hutschiene DIN EN 60715 in your switch cabinet.
- Connect the two power supply cables to VDC1 and VDC2 connectors respectively.
- Connect the functional equipotential bonding contact to the potential-free switching contact.
Configuring Network Connection
Before configuring the network connection, download the ServiceTool software for Windows from the following link: https://sdx.indu- sol.com/s/CtYtsHNW73Z3KCa. After assigning an appropriate IP address and subnet mask, the PROmesh P9+ web interface can be accessed with the factory default settings as follows:
- IP Address : 0.0.0.0
- Subnet Mask : 0.0.0.0
- Gateway : 0.0.0.0
- Username : admin
- Password : admin
Interpreting LED Indicators
The PROmesh P9+ has four LED indicators with the following meanings:
- VDC1 : Voltage at the connection is sufficient
- VDC2 : Voltage at the connection is insufficient
- Status : Active PROFINET connection to the controller
- Error : Voltage failure, port error or configured alarm is active
For more information on interpreting LED indicators, refer to the user manual available at https://sdx.indu-sol.com/s/CtYtsHNW73Z3KCa.
Important Safety Information
The commissioning and operation of this device should only be carried out by qualified personnel who are authorized to commission, ground, and label devices, systems, and circuits in accordance with safety engineering standards. If you need emergency service outside of regular opening hours, call +49(0)34491 / 580-0. For more information on using the PROmesh P9+ and troubleshooting any issues, refer to the user manual available at https://sdx .indu-sol.com/s/CtYtsHNW73Z3KCa.
General Notes
WARNING
Commissioning and operation of this device may be carried out by qualified
personnel only. Qualified personnel are persons who are authorized to
commission, ground and label devices, systems and circuits in accordance with
the standards of safety engineering.
Something‘s wrong with your product?
You can reach our technical support team on weekdays between 07:30 am – 04:30
pm (CET) by telephone: +49(0)34491 / 581-14 or send us an e-mail: support
@indu-sol.com. We will get in touch with you
promptly
Your system is at a standstill?
Reach out to our emergency service even outside our regular opening hours:
+49(0)34491 / 580-0.
Version 1.0 | Date: 22.05.2022 | Product Code: 114110194 Printed in Germany This document is subject to change without notice. © Copyright 2022 Indu-Sol GmbH
Device Connections
X 2 Power Supply and Alarm contact
- VDC1 = DC 24V
- GND = 0V Mass
- VDC2 = DC 24V
- GND = 0V Mass
- Potential-free switching contact functional equipotential bonding
Safety Instructions
Before putting the PROmesh P9+ into operation, check whether it is in perfect
condition externally. Always observe the technical specifications of the
device to ensure safe and optimal use. The PROmesh P9+ is designed for IP20
protection environments. Take appropriate measures to ensure proper operation
of the unit in a different environment.
WARNING
In case of suspected damage, please return the PROmesh P9+ immediately to your
supplier and do not put it into operation. Do not open the housing under any
circumstances. Unauthorized opening of the housing will void any warranty
claims. The PROmesh P9+ is designed for use in PROFINET applications according
to Conformance Class B. For complete support of the PROFINET standards, please
also observe the selection, layout and wiring of the data ports according to
these standards.
Scope of Delivery
- PROmesh P9+
- 7-pole 5 mm terminal block (power supply and alarm contact)
- Quickstart User Guide (hardcopy)
- SD Card, can be used for backup and updates
Mounting on the DIN Rail Mount the PROmesh P9+ upright in the switch cabinet on a 35 mm DIN rail (DIN EN 60715).
NOTE The following distances to other modules must be observed:
- right / left : 50 mm
- top / bottom : 50 mm
WARNING Do not mount the PROmesh P9+ directly next to devices that generate strong electromagnetic interference fields or constantly emit heat to their surroundings. Also protect the PROmesh P9+ from intense sunlight.
Power Supply
The PROmesh P9+ is operated with a redundant DC voltage of 24 VDC, Connect a
suitable power source to the labeled terminals of the 7-pin 2,5 mm2 terminal
block. Connect the positive lead to one of the VDC contacts and the ammunition
lead to the corresponding GND contact. If the external power supply is
correctly connected and activated, all status LEDs of the PROmesh P9+ will
light up briefly. After a short initialization phase the LEDs go out and the
device is ready for operation and can now be configured in the network.
Configuring a Network
Connection Download the Service Tool to your client PC (Windows). You can find the software at the following link https://sdx.indu- sol.com/s/CtYtsHNW73Z3KCa
NOTE
Our software is updated regularly. Please, make sure you are using the latest
version. Connect the PC to a suitable data line on one of the data ports (P1 –
9). The PROmesh P9+ and the client PC must be located in the same IP address
range and IP subnet. For this you have to assign a corresponding IP address to
your PROmesh P9+ for the first time. Use the already installed ServiceTool.
After assigning a suitable IP address and subnet mask, the Web UI of the
PROmesh P9+ can be reached. The PROmesh P9+ is delivered with the following
factory settings:
- IP Adress 0.0.0.0
- Subnet mask 0.0.0.0
- Gateway 0.0.0.0
- Username admin
- Password admin
After successful installation and start of the software, you can scan the system with the search setting PROFINET-Gerät. The PROmesh P9+ is displayed in the search result. You can then make and save individual entries in the input mask.
! NOTE
Make sure that the IP address you selected has not yet been assigned. If
required, you can display IP addresses that have already been assigned using
the PROscan® Active V2 license software from Indu-Sol
WARNING
When logging in for the first time, you must change the factory-set password.
It is your responsibility to document this password and protect it against
unauthorized access
Accessing the Web User Interface
The device-specific functions of the PROmesh P9+ can be configured via an integrated Web-UI. Open your browser, enter the IP address of the PROmesh P9+ configured in the ServiceTool in your browser bar or use the above configuration data. Alternatively, you can right-click on the corresponding list entry in the context menu of the ServiceTool to select „to website“. The Web UI now opens in your standard browser.
NOTE
Further information on the configuration options and troubleshooting can be
found at the following link: https://sdx.indu-sol.com/s/CtYtsHNW73Z3KCa
Interpreting LED Displays
LED label | Mode | Meaning |
---|---|---|
VDC1 | Green | Voltage at terminal sufficient |
Off | Voltage at terminal insufficient | |
VDC2 | Green | Voltage at terminal sufficient |
Off | Voltage at terminal insufficient | |
Status | Green | Active connection to the PROFINET controller |
Yellow | No active connection to the PROFINET controller | |
Error | Red | Power failure, port error or configured alarm active |
Off | No power failure, no port error and no confi- gured alarm active |
Indu-Sol GmbH Blumenstraße 3 04626 Schmoelln Germany
- Telephone : +49 (0) 34491 580-0
- Telefax : +49 (0) 34491 580-499
- info@indu-sol.com
- www.indu-sol.com
Certified according to DIN EN ISO 9001:2015
All accompanying materials of the product can be found at: https://sdx.indu- sol.com/s/CtYtsHNW73Z3KCa
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>