AIRZONE KNX Aidoo Control
Product Information
The Aidoo KNX controller is a device used to manage and integrate HVAC units in KNX TP-1 control systems. It is externally powered by the indoor unit and offers various features:
- I1 – Digital input 1
- I2 – Digital input 2
- I3 – Digital input 3
- KNX Connection – Indoor unit port for KNX programming
- Device reboot – Enables device reboot
The device can be mounted using screws or double-sided adhesive tape (included with the product). It has a standard KNX connector for connecting to the KNX bus.
Product Usage Instructions
-
Assembly:
- Mount the device using screws or double-sided adhesive tape.
-
Connection:
- Refer to the technical data sheet that comes with the Aidoo for instructions on connecting the device to the AC unit.
- Connect the Aidoo to the KNX TP-1 bus, following the color code.
-
Configuration:
-
The Aidoo device is compatible with KNX. Configure and set it up through the ETS tool.
-
Download the product database from this link:
http://doc.airzone.es/producto/Gama_AZ6/Airzone/Aidoo/BBDD_AZAI6KNX.zip -
Install the database in the ETS tool by following the usual procedure for importing new products.
-
-
Communication Objects:
- Default communication objects available in ETS for the Aidoo KNX device:
- Object number 1: Control On/Off
- Description: Allows switching the AC unit on or off
- Values: 0 -> Off, 1 -> On
- Type of access to the Bus: Write
- Data point identification: 1.001 (DPT_Switch)
- Object number 2: Control Mode
- Description: Allows changing the AC unit’s operating mode
- Values: 0 -> Auto, 1 -> Heat, 3 -> Cool, 9 -> Fan, 14 -> Dry
- Type of access to the Bus: Write
- Data point identification: 20.105 (DPT_HVACContrMode)
- Object number 12: Control fan speed / 3 speed
- Description: Allows changing the AC unit’s ventilation speed
- Values: 0…49% -> Speed 1, 50…82% -> Speed 2, 83…100% -> Speed 3
- Type of access to the Bus: Write
- Data point identification: 5.001 (DPT_Scalling), 5.010 (DPT_Enumerated)
- Object number 18: Control Vanes U-D/5 pos
- Description: Allows changing the position of the slats in the AC unit
- Type of access to the Bus: Write
- Data point identification: N/A
Warnings and environmental policy
PRECAUTIONS
For your security, and to protect the devices, follow these instructions:
- Do not handle the system with wet or damp hands.
- Disconnect the power supply before making any connections.
- Take care not to cause a short circuit in any of the system connections.
ENVIRONMENTAL POLICY
Do not dispose of this equipment in the household waste. Electrical and electronic equipment contain substances that may damage the environment if they are not handled appropriately. The symbol of a crossed-out waste bin indicates that electrical equipment should be collected separately from other urban waste. For correct environmental management, it must be taken to the collection centers provided for this purpose, at the end of its useful life. The equipment’s components may be recycled. Act in accordance with current regulations on environmental protection. If you replace it with other equipment, you must return it to the distributor or take it to a specialized collection center. Those breaking the law or by-laws will be subject to such fines and measures as are laid down in environmental protection legislation
General requirements
Strictly follow the directions outlined in this manual
- This system must be installed by a qualified technician.
- Verify that the units to be controlled have been installed according to the manufacturer’s requirements and operate correctly before installing the Airzone System.
- Locate and connect all the devices of the installation in accordance with the electronic regulations in force.
- Verify that the air conditioning installation to be controlled is in accordance with the regulations in force.
- Perform all the connections with total absence of power supply.
- Do not place the system bus close to lines of force, fluorescent lights, LED lamps, motors, etc. It might cause interference on the communications.
Respect the connection polarity of each device. A wrong connection may seriously damage the product.
Introduction
Device to manage and integrate HVAC units in KNX TP-1 control systems. Externally powered by the indoor unit. Features:
- Control of the parameters of the unit.
- KNX Control.
- KNX standard data.
- 3 digital inputs.
- Easily configurable from ETS.
- Communication errors detection.
Assembly
The device can be mounted using screws or double-sided adhesive tape (included with the product).
Connection
To connect the device to the AC unit, follow the instructions on the technical
data sheet that comes with the Aidoo.
It has a standard KNX connector for connecting to the KNX bus. Connect the
Aidoo to the KNX TP-1 bus, following the color code.
Configuration
- This device is totally compatible with KNX, so you can configure it and set it up through ETS tool.
- To do this, download the product database at: http://doc.airzone.es/producto/Gama_AZ6/Airzone/Aidoo/BBDD_AZAI6KNX.zip
- The installation of the database in the ETS tool is carried out following the usual procedure for importing new products.
Communication objects
The Aidoo KNX device has a series of communication objects available for
configuration by default (see the Default communication objects section). If
you wish to use all the communication objects contained in this device, go to
the Parameters tab in order to enable them (see the Configuration Parameters
section for more information).
IMPORTANT : The number of functionalities that can be controlled by the
different communication objects offered by the Aidoo KNX device will depend on
the particular AC unit being controlled.
To view all the communication objects available on the Aidoo KNX device,
please go to Annexes – Index – Communication Objects for more information.
DEFAULT COMMUNICATION OBJECTS
The default communication objects available in ETS for the Aidoo KNX device
are:
Note : You can configure the object type in the Fan Configuration section, under the Parameters tab in ETS. By default it is configured as Datapoint 5.001 (percentage control). See the Configuration Parameters – Fan Configuration section for more information
Note : Configure the object type in the Vanes Up-Down configuration section, under the Parameters tab in ETS. By default it is configured as Datapoint 5.001 (percentage control). See the Configuration Parameters – Vanes Up-Down configuration section for more information
Note : Configure the object type in the Vanes Up-Down configuration section, under the Parameters tab in ETS. By default it is configured as Datapoint 5.001 (percentage control). See the Configuration Parameters – Vanes Up-Down configuration section for more information.
Note : Configure the object type in the Vanes Up-Down configuration section, under the Parameters tab in ETS. By default it is configured as Datapoint 5.001 (percentage control). See the Configuration Parameters – Vanes Up-Down configuration section for more information
CONFIGURATION PARAMETERS
The Aidoo KNX device has a series of communication objects that can be enabled for use via the Parameters tab in ETS.
General
Enable use of objects for filter
Enable comm obj “Status_Remote Lock”
Enable comm obj “Ctrl_ /Status_Control Lock”
Mode configuration
Enable “Mode Cool/Heat” objects
Enable PID-Compat Scaling Mode Objects
Enable use of bit-type Mode objects
Enable use of +/- object for mode
Select whether you want to use Datapoint DPT 1.007 (0 = Decrease) or DTP 1.008
(0 = Increase).
Enable use of text object for Mode
Fan configuration
DPT object type for fan speed
Select whether you want to use Datapoint DPT 5.001 (percentage control) or DTP 5.010 (number control) for controlling and reading the AC unit’s ventilation speed status
Enable use of bit-type Fan Speed objects
Enable use of +/- object for fan speed
Select whether you want to use Datapoint DPT 1.007 (0 = Decrease) or DTP 1.008
(0 = Increase
Enable use of Text object for fan speed
Vanes Up-Down configuration
DPT object types for Vanes Up-Down
Select whether you want to use Datapoint DPT 5.001 (percentage control) or DTP 5.010 (number control) for controlling and reading the status of the AC unit’s slats
Enable use of bit-type Vanes Up-Down objects
Enable use of +/- Object for Vanes Up-Down
Select whether you want to use Datapoint DPT 1.007 (0 = Decrease) or DTP 1.008
(0 = Increase).
Enable use of text object for Vanes Up-Down
Temperature configuration
Periodic sending of “Status_AC Setpoint” (in seconds, 0=No periodic sending)
Indicate how often you want the setpoint temperature status to be sent to the
AC unit (in seconds).
Enable use of +/-object for setpoint
Select whether you want to use Datapoint DPT 1.007 (0 = Decrease) or DTP 1.008
(0 = Increase).
Enable limits on Control_Setpoint obj
Select the minimum and maximum setpoint temperature that can be set for the AC
unit (in increments of 1°C).
Ambient temperature is provided by KNK
This enables/disables ambient temperature reading from a KNX device.
Timeouts configuration
- Enable use of Open window. If you select Yes, object 32 will be enabled.
- AC Window Timeout (min). Select the time after which the AC unit will turn off, following the receipt of an open window warning (0) (from 0 to 255 minutes). If the window closes (1) during this time, the timer will be canceled.
- Disallow On/Off operation when timeout is elapsed. Select whether you want to allow the AC unit to be switched on/off when the selected timeout has elapsed.
- Enable use of Switch off timeout function. If you select Yes, object 33 will be enabled.
- AC switch-off timeout (min). Select the time after which the AC unit will turn off, following the receipt of a warning that the switch has been activated (1) (from 0 to 255 minutes). If the switch is deactivated (0) during this time, the timer will be canceled.
- Disallow On/Off operation when timeout is elapsed. Select whether you want to allow the AC unit to be switched on/off when the selected timeout has elapsed.
- Enable use of Occupancy Window. If you select Yes, object 34 will be enabled.
- Timeout to applied actions (min). Select the time after which the AC unit will carry out the selected action, following the receipt of a warning that the contact has been activated (1) (from 0 to 255 minutes). If the contact is deactivated (0) during this time, the timer will be canceled.
- Action after timeout elapsed. Select the action to be carried out after the timeout has elapsed: Switch off the AC unit or put it into unoccupied mode (the setpoint temperature will change by 1°C for each time interval set, up to a total of 3°C, after which the unit will be switched off).
- Disallow On/Off operation when not occupied. Select whether you want to allow the AC unit to be switched on/off when the selected timeout has elapsed.
- Enable use of the Sleep function. If you select Yes, object 35 will be enabled.
- Slepp function switch-off timeout (min). Select the time after which the AC unit will turn off, following the receipt of a warning that the switch has been activated (0) (from 0 to 255 minutes). If the switch is deactivated (1) during this time, the timer will be canceled.
Scenes configuration
Enable the use of scenes
Enable use of bit object for storing scenes (you must have the Enable use of scenes parameter enabled)
Enable use of bit object for scene execution (you must have the Enable use of scenes parameter enabled)
Scene 1 / 2 / 3 / 4 (you must have the Enable use of scenes parameter
enabled).
Select the scene ID (values available from 0 to 63). If you wish to configure
each scene from ETS, activate the System Preset parameter and configure the
values of each parameter for the desired AC unit:
- Value for On-Off: Select if you want to turn the AC unit on/off, or if you do not want to carry out any action.
- Value for mode: Select if you want to change the AC unit’s operating mode, or if you do not want to carry out any action.
- Value for fan speed: Select if you want to change the AC unit’s ventilation speed, or if you do not want to carry out any action.
- Value vanes U-D: Select if you want to modify the position of the AC unit’s slats, or if you do not want to carry out any action.
- Value for Setpoint: Select if you want to change the AC unit’s setpoint temperature (16 – 30°C), or if you do not want to carry out any action.
Inputs configuration
Enable the use of the Aidoo KNX digital inputs:
- Input 1: Communication objects 87 and 88.
- Input 2: Communication objects 89 and 90.
- Input 3: Communication objects 91 and 92.
The objects will behave differently depending on the configuration of each input.
Parameters available for configuring each digital input:
- Contact type. Defines the contact logic as Normally Open or Normally Closed.
- Debounce time. Select the debounce time (in milliseconds) required for the system to recognize there has been a change in the contact.
- Disabling input object. Select whether or not you want to enable the object that allows the input to be disabled if necessary (communication objects 48, 49 and 50). If yes, select whether you want to use Datapoint DPT 1.002 (0 = False) or DTP 1.003 (0 = Disable).
- Function. Select the digital input function of the Aidoo KNX:
- Switching
- Send telegram after bus recovery. Select the action to be performed on this digital input after bus recovery (after a power failure): no action, off (0), on (1) or current status.
- Sending delay after bus recovery. If an action is selected, indicate the time delay for sending the telegram (in seconds).
- Value on raising Edge (contact activated). Select the action to be sent to the associated communication object, if it produces a rising edge (activated input): no action, off (0), on (1) or toggle.
- Value on falling Edge (Contact deactivated). Select the action to be sent to the associated communication object, if it produces a falling edge (deactivated input): no action, off (0), on (1) or toggle.
- Cyclical sending. Select if you want cyclical sending to occur depending on the status of the digital input: never, always, when the output value is Off, or when the output value is On.
- Period for cyclical sending (s). If cyclical sending is selected, indicate the time period (in seconds) for this cycle.
- Dimming
- Send telegram after bus recovery. Select the action to be performed on this digital input after bus recovery (after a power failure): no action, off (0) or on (1).
- Sending delay after bus recovery. If an action is selected, indicate the time delay for sending the telegram (in seconds).
- Mode for short (long) operation. Select the action for a short operation to be sent on a rising edge (activated input): toggle, off/decrease (0) or on/increase (1). A press and hold will result in either an increasing step or a decreasing step.
- Increasing step. Select the percentage of the increasing step that will be sent for a long operation.
- Decreasing step. Select the percentage of the decreasing step that will be sent for a long operation.
- Short/long operation limit (ms). Defines the time that must elapse for the object to interpret that a long operation has occurred (in milliseconds).
- Cyclical sending period in long operation (0-No cyclical sending) (ms). Defines the time (in seconds) during which the long operation must be executed
- Shutter/blind
- Send telegram after bus recovery. Select the action to be performed on this digital input after bus recovery (after a power failure): no action, increase (0) or decrease (1).
- Sending delay after bus recovery. If an action is selected, indicate the time delay for sending the telegram (in seconds).
- Operation. Select the action to be sent on a rising edge (activated input): increase (0), decrease (1) or toggle.
- Method. Select the operating method for the shutter/blind: step-move-step or move-step.
- Step-Move-Step. On a rising edge (activated input) a step telegram will be sent and the counter defined in “Short/long operation limit (ms)” (counter 1) will start. Note: No action will be taken if a falling edge (deactivated input) occurs during this time. If the rising edge is maintained for longer than the time defined in counter 1, a move telegram will be sent and a second counter, defined in “Vanes adjustment time (ms)” (counter 2), will start. If a falling edge (deactivated input) occurs during the time specified in this second counter, a step telegram will be sent. Note: No action will be taken if a falling edge (deactivated input) occurs after this time.
- Move-Step. On a rising edge (activated input), a move telegram will be sent and counter 2 will start (“Vanes adjustment time” (ms)). If a falling edge (deactivated input) occurs during this time, a stop telegram will be sent. Note: No action will be taken if a falling edge (deactivated input) occurs after this time.
- Shot/long operation limit (ms). Defines the time that must elapse (counter 1) between a short operation and a long operation (in milliseconds).
- Vanes adjustment time (ms). Defines the time that must elapse (counter 2) before adjusting the slats or moving the shutter/blind (in milliseconds).
- Value
- Send telegram after bus recovery. Select if you want to send an action (fixed value) on this digital input after bus recovery (after a power failure) or if you do not want to send any action.
- Sending delay after bus recovery. If an action is selected, indicate the time delay for sending this telegram (in seconds).
- DTP to be sent. Select the type of DTP to be sent:
- DTP 5.010 (1 byte unsigned). Values: 0 … 255
- DTP 7.001 (2 bytes unsigned). Values: 0 … 655335
- DTP 8.001 (2 bytes signed). Values: -32768 … 32767
- DTP 9.001 (temperature). Values: 0 … 255
- DTP 12.001 (4 bytes unsigned). Values: 0 … 4294967295
- Value on raising edge (when contact activated). Defines the value to be sent when the contact is activated
- Scene (internal). Activates a scene by activating the configured digital input.
- Scene when contact is activated. Select the scene that will be activated when the digital input is activated.
- Occupancy (internaal). Switches to Occupied mode when the configured digital input is activated.
- Window (internal). Activates the Window Contact timer when this digital input is activated
Communication objects
Digital input status Digital input I1
Digital input I2
Digital input I3
Disable digital inputs
KNX parameters for Samsung
SA2 PROTOCOL