Product Information

  • Product Name: GS6-AAAxBBB-CC
  • LED Color: RGB / Red / Amber
  • Active Area: 18′ 8-5/8 [5706] x 22′ 1-3/16 [6736]
  • Overall Size: 19′ 2-13/16 [5863] x 22′ 7-3/8 [6893]
  • Cabinet Material: Aluminum & Steel
  • Ventilation: Rear Intake & Exhaust
  • Access: Service from Front of Display
  • Weight: Section 101 – 2415 lbs [1095 kg] (approx), Section 201 – 2415 lbs [1095 kg] (approx), Total – 4830 lbs [2191 kg] (approx)
  • Shipping: Shipped in two sections. Assembly of sections is required on-site.
  • Structural Rating: 1

Product Usage Instructions

  1. Ensure the light sensor is not blocked.
  2. For proper ventilation, ensure there is clearance for exhaust vents and intake vents. Refer to Ventilation Notes #1 and #2 for more details.
  3. Follow Install Notes #11 for installation.
  4. For clarity, note that portions of the top border covers are removed. Refer to Install Note #4 for more clarification.
  5. Refer to Install Note #9 for the rear of the display, which is made of mill-finish aluminum.
  6. Refer to Install Note #6 for the power entrance. Use primary signal input quick connect as specified in Install Note #7.
  7. The optional signal entrance can be used as specified in Install Note #8. A ground lug is available as mentioned in Install Note #5.
  8. Refer to Install Note #10 for signal interconnect.
  9. For installation, refer to Install Notes #1, #2, and #3 for the distance between lift lugs, and Install Note #11 for T-Clips.
  10. Refer to Detail A for a scale of 1/18.
  11. Refer to Detail B for a scale of 1/18.
  12. Refer to Detail C for a scale of 1/18. Also, refer to Hardware Specifications on Detail C.
  13. Refer to Detail D for a scale of 1/18. Weld specifications are mentioned on Detail D.

OVERALL DISPLAY SIZE: GS6-AAAxBBB-CC

PIXELS HIGH (AAA) PIXELS WIDE (BBB) PIXEL SPACING (CC)
360 425 15.85mm
288 340 19.81mm
216 255 26.42mm

DIMENSION

Daktronics-Gs6-Galaxy-Displays-fig-1 \(4\) Daktronics-Gs6-Galaxy-Displays-fig-1 \(6\) Daktronics-Gs6-Galaxy-Displays-fig-1 \(7\) Daktronics-Gs6-Galaxy-Displays-fig-1 \(8\)

Daktronics-Gs6-Galaxy-Displays-fig-1 \(1\)

VENTILATION REQUIREMENTS

  1. DISPLAY RELIES ON VENTILATION TO FUNCTION PROPERLY. VENTILATION HOODS, LOCATED AT THE BACK OF THE DISPLAY, MUST BE ABLE TO DRAW IN AIR AT A TEMPERATURE NO GREATER THAN 120°F
  2. AIRFLOW AT AMBIENT TEMPERATURE CAN BE MAINTAINED BY PROVIDING OPENINGS FOR INTAKE (AT THE BOTTOM) AND EXHAUST (AT THE TOP) BEHIND THE DISPLAY. A MINIMUM OF 12.0 SQFT FOR INTAKE AND 12.0 SQFT FOR EXHAUST IS REQUIRED. IF THE OPENINGS CANNOT BE PROVIDED AS STATED, USE WALL-MOUNT PROPELLER FANS TO GENERATE A MINIMUM OF 3600 CFM OF AIRFLOW ACROSS THE BACK OF THE DISPLAY.

INSTALL NOTES

  1. WHEN LIFTING USE ALL LIFTLUGS AND MAINTAIN AN ANGLE LARGER THAN 55° BETWEEN THE CABINET AND THE LIFTING DEVICE.
  2. 1-1/16″ LIFTLUG DIAMETER TO ASSIST WITH DISPLAY INSTALLATION. MAX WIND SPEED DURING INSTALLATION MUST BE LESS THAN 20 MPH.
  3. LIFTLUGS MAY NOT BE USED FOR PERMANENT INSTALLATION.
  4. THE DISPLAY WILL BE SHIPPED WITH SOME TOP BORDER COVERS REMOVED. COVERS WILL NEED TO BE ATTACHED WITH INCLUDED HARDWARE AFTER THE DISPLAY IS MOUNTED TO THE STRUCTURE.
  5. GROUND LUG FOR GROUND CONNECTION. ALL SECTIONS NEED TO BE GROUNDED.
  6. 2″ MEYERS HUB FOR POWER TERMINATION TO INTERNAL LOAD CENTER. SEE POWER RATINGS ABOVE.
  7. SIGNAL INPUT AT QUICK CONNECT. PRIMARY/SINGLE FACE DISPLAY SHOWN. SEE CLEARANCE DIMENSION ON LEFT SIDE VIEW.
  8. TWO 1/2″ CONDUIT KNOCKOUTS FOR OPTIONAL SIGNAL ENTRANCE.
  9. DISPLAY WILL BE PAINTED SEMI-GLOSS BLACK ON THE FRONT AND SIDE PERIMETER WITH MILL FINISH ALUMINUM ON THE REAR OF THE DISPLAY.
  10. MECHANICAL AND SIGNAL CONNECTIONS OCCUR EXTERNAL TO THE DISPLAY.
  11. T-CLIPS FOR MOUNTING.T-CLIPS CAN BE ADJUSTED VERTICALLY 1/2″ AS NEEDED DURING INSTALLATION. T-CLIPS CAN BE WELDED OR BOLTED TO STRINGER AT A MAX DISTANCE 2-1/2″. SEE DETAILS C & D.
  12. DAKTRONICS IS NOT RESPONSIBLE FOR THE MOUNTING HARDWARE OR THE INTEGRITY OF THE MOUNTING STRUCTURE.
  13. DAKTRONICS IS NOT RESPONSIBLE FOR THE MAIN ELECTRICAL DISCONNECT. SEE POWER RATINGS ABOVE.
  14. FOR MORE INSTALLATION DETAILS AND GUIDELINES REQUEST DD-1954173 FROM YOUR DAKTRONICS REPRESENTATIVE

THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BY ANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OF DAKTRONICS, INC. OR ITS WHOLLY-OWNED SUBSIDIARIES. COPYRIGHT 2018 DAKTRONICS, INC. (USA)

THIRD ANGLE PROJECTION

  • PROJECT: GS6 GALAXY DISPLAYS
  • TITLE: SHOP DWG, GS6-R, 19′ 3”x22′ 8” (18×17 MODS)
  • DATE: 10-MAR-23
  • SCALE: 1/90
  • DESIGN: TWHITEH
  • DRAWN: MLEOPOL
  • DIM UNITS: INCHES [MILLIMETERS]

DO NOT SCALE DRAWING

  • JOB NO. P1874
  • FUNC – TYPE – SIZE: E – 07 – B
  • SHEET: 1 OF 1