FIREMAGIC 3092B 1 Hour Automatic Barbecue Timer Gas Shut Off Valve Owner’s Manual
- June 3, 2024
- FIREMAGIC
Table of Contents
FIREMAGIC 3092B 1 Hour Automatic Barbecue Timer Gas Shut Off Valve
INSTALLER : Leave these instructions with consumer.
CONSUMER : Retain for future reference.
WARNING : AFTER EACH USE:
- MAKE CERTAIN THAT THE APPLIANCE KNOBS ARE IN THE OFF POSITION.
- TURN OFF THE GAS SUPPLY SHUT-OFF VALVE.
- IF TIMER IS ON, SLOWLY TURN IT TO THE OFF POSITION.
SPECIFICATIONS
- 100,000 B.T.U., Natural Gas@ 0.6 SP.@ 7″ W.C.
- 100,000 B.T.U., Propane Gas@ 1.53 SP.@ 11″ w.c.
- Maximum working pressure not to exceed½ P.S.I.G.
- Maximum ambient operating range: from 0° F (-18° C) to 150° F (65.6° C).
INSTALLATION REQUIREMENTS
- Timer MUST be installed in accordance with local codes or, in the absence of local codes, in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA54, or the Natural Gas & P ropane Installation Code, CSA 8149.1, as applicable.
- Timer MUST be installed in-line between the shut-off valve and the gas appliance.
- Timer MUST be installed a minimum of 18″ away from the appliance or it will overheat, causing damage to the timer and may result in a leak.
- Timer MUST be installed within 6 feet of the appliance. If it is located within the appliance enclosure, it must be easily accessible.
- Timer MUST be protected from high temperatures and outdoor elements.
- Use pipe joint compound resistant to all gasses on all NPT fittings except flare fittings. Be sure to leak test at all connections.
INSTALLATION
In addition to following the CONNECT GAS SUP PLY section of the gas appliance owner’s manual, install the timer in the gas supply line (between the shut-off valve and the appliance). See Fig. 1-1 and 1-2.
- Ensure you connect the line coming from the gas supply to the side marked ”IN” on the timer.
- The timer accommodates 1/2 NPT piping (both ends).
- Follow all information found in the requirements section above, in the gas appliance owner’s manual. and fig 1-1 and 1-2.
- The timer can be installed horizontally or vertically.
OPERATION
To use, set the dial (turn clockwise) to the desired time to shut off. The
dial is marked in 3 twenty minute increments (any position in between is an
estimate of that set time).The timer dial will auto rotate (counter-clockwise)
and will shut off the gas supply when the dial reaches OFF (i.e. the desired
time is completed).
Important : When using the timer for periods of less than twenty minutes,
you must first set the dial to 20 minutes (to activate). then return (counter-
clockwise) to the desired amount of time. This will ensure proper timer
operation. See Fig. 2-1.
WARNING : A FT ER E A CH U SE:
- MAKE CERTAINTHATTHE A PPLIA NCE CONTROL KNOBS ARE IN THE OFF POSITION.
- TURN OFFTHE G A S SU PPLY SHUT-OF F VALVE.
- IF TIMER IS ON, SLOWLY TURN IT TO THE OFF POSITION.
Read User Manual Online (PDF format)