PLR Installation

Refer to the contract-specific Riser Diagram for the correct PLR location. The PLR hook mounts to the center vertical inside the display and secures with a screw.

  1.  Use a 5/16″ nutdriver to remove the screw from the mounting plate. Refer to Figure 2.
  2.  Line up the tabs on the side of the mounting plate with the hook mount on the center vertical inside the panel. Refer to Figure 3.
  3.  Secure the mounting plate to the panel with the screw removed in Step 1.

Signal Connection

The panels daisy-chain between sections per the contract-specific Riser Diagram.

  1.  Connect a Cat 5e/Cat 6 cable from the panel to the PLR.
  2.  Route the Cat 5e/Cat 6 cable hanging loosely from the panel and plug it into the adjacent panel-mounted RJ45 jack.
  3.  Connect the last panel back to the PLR for redundant signal connection. Refer to the Riser Diagram.

Refer to Figure 4 for an example of four panels connected together. Standard signal routing is horizontal with configurable jumpers available to vertically jump a row if necessary.DAKTRONICS-DVN-3001-Indoor-Video-Scoreboards-
fig-3

Power Connection

Standard panels include power quick connects with pre-terminated connectors at each end. Power interconnect cables are shipped with the displays. A new field power input cable is required for every 12 panels when using a one-phase power entrance and for every 36 panels when using a three-phase power entrance. Refer to the contract-specific Riser Diagram for more details. Both vertical and horizontal interconnects are available. A typical horizontal solution is depicted in Figure 5. Standard power routing is horizontal with configurable jumpers available to vertically jump a row if necessary. DAKTRONICS-DVN-3001
-Indoor-Video-Scoreboards-fig-4

A configurable power termination panel will be installed on-site. Refer to the contract-specific Riser Diagram for more details.

Power Entrance

Refer to the contract-specific Riser Diagram for the correct power entrance location. The power entrance hook mounts to the center vertical inside the display and secures with a screw.

  1.  Use a 5/16″ nutdriver to remove the screw from the mounting plate. Refer to Figure 6 and Figure 7.
  2.  Line up the tabs on the side of the mounting plate with the hook mount on the center vertical inside the panel. Refer to Figure 8.
  3.  Secure the mounting plate to the panel with the screw removed in Step 1.

Connect the power harnesses together between panels for power interconnection. Refer to the contract-specific Riser Diagram for more details.

Module Installation

Panels have four modules as shown in Figure 9.

  1.  Disconnect power to the display.
  2.  Align the connector on the rear of the module with the corresponding connector on the panel.
  3.  Place the module into position. Press firmly (with a gloved hand flat against the module face) in locations shown.

Follow the front-access and rear-access module removal steps in the DVN-3001 Series Service Quick Guide (DD4774243) to remove a module.