DAKTRONICS DVN-3001 Indoor Video Scoreboards User Guide
- June 5, 2024
- DAKTRONICS
Table of Contents
DAKTRONICS DVN-3001 Indoor Video Scoreboards
Electrical
PLR Installation
Refer to the contract-specific Riser Diagram for the correct PLR location. The PLR hook mounts to the center vertical inside the display and secures with a screw.
- Use a 5/16″ nutdriver to remove the screw from the mounting plate. Refer to Figure 2.
- Line up the tabs on the side of the mounting plate with the hook mount on the center vertical inside the panel. Refer to Figure 3.
- Secure the mounting plate to the panel with the screw removed in Step 1.
Signal Connection
The panels daisy-chain between sections per the contract-specific Riser Diagram.
- Connect a Cat 5e/Cat 6 cable from the panel to the PLR.
- Route the Cat 5e/Cat 6 cable hanging loosely from the panel and plug it into the adjacent panel-mounted RJ45 jack.
- Connect the last panel back to the PLR for redundant signal connection. Refer to the Riser Diagram.
Refer to Figure 4 for an example of four panels connected together. Standard signal routing is horizontal with configurable jumpers available to vertically jump a row if necessary.
Power Connection
Standard panels include power quick connects with pre-terminated connectors at each end. Power interconnect cables are shipped with the displays. A new field power input cable is required for every 12 panels when using a one-phase power entrance and for every 36 panels when using a three-phase power entrance. Refer to the contract-specific Riser Diagram for more details. Both vertical and horizontal interconnects are available. A typical horizontal solution is depicted in Figure 5. Standard power routing is horizontal with configurable jumpers available to vertically jump a row if necessary.
A configurable power termination panel will be installed on-site. Refer to the contract-specific Riser Diagram for more details.
Power Entrance
Refer to the contract-specific Riser Diagram for the correct power entrance location. The power entrance hook mounts to the center vertical inside the display and secures with a screw.
- Use a 5/16″ nutdriver to remove the screw from the mounting plate. Refer to Figure 6 and Figure 7.
- Line up the tabs on the side of the mounting plate with the hook mount on the center vertical inside the panel. Refer to Figure 8.
- Secure the mounting plate to the panel with the screw removed in Step 1.
Connect the power harnesses together between panels for power interconnection. Refer to the contract-specific Riser Diagram for more details.
Module Installation
Panels have four modules as shown in Figure 9.
- Disconnect power to the display.
- Align the connector on the rear of the module with the corresponding connector on the panel.
- Place the module into position. Press firmly (with a gloved hand flat against the module face) in locations shown.
Follow the front-access and rear-access module removal steps in the DVN-3001 Series Service Quick Guide (DD4774243) to remove a module.