DAKTRONICS DVN-3001 Series Panel Installation Guide

June 3, 2024
DAKTRONICS

DAKTRONICS DVN-3001 Series Panel

Mechanical

Panel Interconnect Engagement

  1. Push the knurled captivated bolts through the cabinet to attach the adjacent cabinets. Refer to Figure 1.DAKTRONICS DVN-3001 Series Panel-1
  2. Hand-tighten the knurled captivated bolts loosely until the cabinets are mated but still able to move for adjusting.
  3. Check the top-to-bottom panel alignment to ensure the panels are level. Adjust the jacking hardware until the panels are flush.
  4. Finish hand-tightening the captivated bolts as much as possible and then use a Phillips or standard screwdriver to do a final 1/2 to 3/4 turn.
  5. Feel the top, bottom, and center of the seam to ensure the seam between the panels feels smooth, ensuring proper panel alignment.

Self-Drilling Screw Installation

Use the contract-specific Shop Drawing to determine self-drilling screw quantities and locations per panel.
If standard 1/4″-14 screws are being used, use a pilot hole size of 13/64″ [5.16 mm]. If alternative screws are being used, find the correct pilot hole size per the hardware specified on the contract-specific Shop Drawing.

  1. Mark the locations of the self-drilling screws and drill pilot holes at those locations if pilot holes do not already exist.
    Note: For 1×4 tubes, pilot holes must be drilled through both the front and rear walls of the tube to prevent screw strip-out.

  2. Start the attachment of the self-drilling screws in the pilot holes, but do not tighten the screws down.

201 Daktronics Drive
Brookings, SD 57006-5128
www.daktronics.com/support
800.325.8766

DD4836909
Rev 01
12 August 2021