Product Information

The ELKO Smart Smoke Alarm is a 230V device that provides
advanced smoke detection capabilities. The device comes with
several features and functionalities that make it an ideal choice
for residential and commercial use. The following are some of the
key features of the device:

  • Advanced smoke detection technology
  • Easy to install and pair with other devices
  • High-quality design and construction
  • Comes with a user-friendly manual for easy operation

Product Usage Instructions

Safety Information

Before attempting to install, operate, service, or maintain the
ELKO Smart Smoke Alarm, it is important to read and understand the
safety information provided in the user manual. The following are
some of the key safety considerations:

  • Only qualified personnel should install, operate, service, and
    maintain the device

  • Pay attention to all safety messages and warnings to avoid
    possible injury or death

  • Electrical hazards exist which could result in personal injury
    if instructions are not followed

  • Danger and warning symbols indicate hazardous situations that
    require immediate attention to avoid serious injury or death

Installation

The ELKO Smart Smoke Alarm is designed for easy installation.
Follow the steps below to install the device:

  1. Choose a suitable location for the device. The device should be
    installed on the ceiling or wall in accordance with local
    regulations.

  2. Turn off the power supply to the area where you plan to install
    the device.

  3. Remove the mounting plate from the device and attach it to the
    ceiling or wall using screws and anchors.

  4. Connect the device to the power supply using the provided
    wiring diagram. Ensure that all connections are secure and properly
    insulated.

  5. Attach the device to the mounting plate and test its
    functionality by pressing the test button.

Pairing

The ELKO Smart Smoke Alarm can be paired with other devices for
enhanced functionality. Follow the steps below to pair the
device:

  1. Ensure that all devices are powered off before attempting to
    pair them.

  2. Place the device in pairing mode by pressing and holding the
    pairing button for 5 seconds.

  3. Activate pairing mode on the other device by following the
    manufacturer’s instructions.

  4. Wait for the devices to establish a connection. This may take a
    few minutes.

  5. Test the devices to ensure that they are functioning
    properly.

For more detailed information on product usage, refer to the
user manual provided with the device or visit the ELKO website at
www.elko.no.

ELKO – Smart Smoke Alarm 230 V
Device user guide
Information about features and functionality of the devices 05/2023
www.elko.no

Legal Information
The ELKO brand and any trademarks of ELKO AS and its subsidiaries referred to in this guide are the property of ELKO AS or its subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished for informational use only. No part of this guide may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of ELKO.
ELKO does not grant any right or license for commercial use of the guide or its content, except for a non-exclusive and personal license to consult it on an "as is" basis. ELKO products and equipment should be installed, operated, serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by ELKO and its subsidiaries for any errors or omissions in the informational content of this material or consequences arising out of or resulting from the use of the information contained herein.

Table of Contents
Safety information……………………………………………………………………………4 ELKO – Smart Smoke Alarm 230 V ………………………………………………….5
For your safety ……………………………………………………………………………….5 About the device……………………………………………………………………………..6 Installing the device …………………………………………………………………………6 Pairing the device ……………………………………………………………………………7
Pairing device manually……………………………………………………………….7 Pairing device with auto scan………………………………………………………..9 Setting up connection without ELKO SmartHUB……………………………………10 Interconnecting devices without ELKO SmartHUB……………………………10 Disconnecting a secondary device ………………………………………………. 11 Testing the device………………………………………………………………………….12 Configuring the device ……………………………………………………………………13 Changing the device icon …………………………………………………………..13 Renaming the device ………………………………………………………………..14 Changing the device location ………………………………………………………14 Using the device……………………………………………………………………………15 Checking the device history ………………………………………………………..16 Setting LED brightness………………………………………………………………17 Test alarm reminder ………………………………………………………………….18 Silencing the device ………………………………………………………………….19 Snoozing the device alerts………………………………………………………….20 False alarm …………………………………………………………………………….20 Creating an automation ……………………………………………………………..21 Removing the device from the app …………………………………………………….26 Resetting the device manually ………………………………………………………….26 Maintenance and cleaning……………………………………………………………….27 LED Indications …………………………………………………………………………….28 Troubleshooting ……………………………………………………………………………29 Technical Data ……………………………………………………………………………..29

DUG_Smoke Alarm AC_ELKO-00

3

Safety information

Safety information

Important information
Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of either symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that accompany this symbol to avoid possible injury or death.

DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. Failure to follow these instructions will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.

4

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
ELKO – Smart Smoke Alarm 230 V
EKO09764
For your safety
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Safe electrical installation must be carried out only by skilled professionals. Skilled professionals must prove profound knowledge in the following areas: · Connecting to installation networks · Connecting to several electrical devices · Laying electrical cables · Safety standards, local wiring rules and regulations Failure to follow these instructions will result in death or serious injury.
NOTICE
EQUIPMENT INSTALLATION HAZARD · Always operate the product in compliance with the specified technical data. · Keep the installation instruction for the life of the product. Failure to follow these instructions can result in equipment damage.
WARNING
SEALED BATTERY HAZARD Do not recharge, disassemble or incinerate the battery. Failure to follow these instructions can result in death, serious injury, or equipment damage.

DUG_Smoke Alarm AC_ELKO-00

5

About the device

ELKO – Smart Smoke Alarm 230 V

The Smart Smoke Alarm 230 V (device) uses a photoelectric sensor to detect smoke generated by fire and a temperature sensor that detects heat caused by rapid increase in temperature. It also includes a backup battery that allows the device to work if the power supply is disconnected. When connected to the ELKO Smart system, the device will send notifications via the ELKO Smart app.

Operating elements
A. Status LED (Amber, Green and Red LED) B. Standby LED (Red LED) C. Test/Hush button D. Power switch: OFF/Auto* E. Setup/Reset button

*OFF/Auto: In this position the device is turned off. When the device is mounted on the mounting base, it turns on automatically. When it is removed, it turns off automatically.
Installation location
· Smoke Alarm can be installed on a flat/inclined ceiling. · Do not install smoke alarms near windows, doors, or ducts. · Avoid paint, stickers, or other decorations.

1 m
M
0.3 m
0.3 m min.
0.5 m min. / 1.5 m max.
Installing the device
Refer to the installation instruction supplied with this product. See Smart Smoke Alarm 230 V.

6

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Pairing the device
Using the ELKO app, pair your device with the ELKO SmartHUB to access and control the device. You can either add the device manually or do an auto-scan to pair it.
IMPORTANT: Do not mount the device before the pairing. The Setup/Reset button (Zigbee) and power switch are located on the rear side of the device. NOTE: When multiple smoke alarms are paired with same ELKO SmartHUB, an 868MHz radio frequency (RF) interconnection is automatically created between smoke alarms.
Pairing device manually
1. Locate the power switch on the rear side of the device. Use a screwdriver to turn the power switch to ON position.
OFF/AUTO
OFF/AUTO ON
ON

NOTE: When the device is mounted on the ceiling, the power switch is automatically turned ON. 2. In ELKO Smart app Home page, tap +.
3. Tap and select the required ELKO SmartHUB on the slide-up menu. 4. Select any one of the options to add device (A):
­ Add Device with Install Code ­ Add Device without Install Code
Add Device

Install Code is Recommended
To enhance network security, we strongly recommend using the install code to add a
device. If you are unable to scan or type the install code, you can still add the device without it.

Add Device with Install Code

A

Add Device without Install Code

TIP: It is highly recommended to pair the device with Install code.

DUG_Smoke Alarm AC_ELKO-00

7

ELKO – Smart Smoke Alarm 230 V
5. To pair the device with an install code,, tap Add Device with Install Code to display the slide-up menu. Select any one of the options (B): ­ Scan Install Code – You can scan the device for the an install code. ­ Enter Install Code Manually – You can manually enter the install code from the device TIP: Install code is located on the rear side of the device. After scanning or entering the install code, proceed to Step 7.
Add Device

Install Code is Recommended
To enhance network security, we strongly recommend using the install code to add a
device. If you are unable to scan or type the install code, you can still add the device without it.

Add Device with Install Code

Add DevSiccaenwIintshtoaulltCInodsetall Code

B

Enter Install Code Manually

Cancel

6. To pair the device without install code, tap Add Device without Install Code. 7. Short press the Setup/Reset button 3 times.

OFF/AUTO ON

3× < 2 s

DO NOT PAINT

PUSH TO TEST / HUSH

The LED blinks yellow. 8. In the app, select LED is blinking yellow and tap Start Configuration (C).

Cancel
How to pair device 1. Turn the Power switch located at the rear
side of the device to ON position. Note: Use a screwdriver to turn the switch. 2. Tap Set/Reset button for 3 times.

DO NOT PAINT

PUSH TO TEST / HUSH

LED is blinking yellow
C

8

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
9. After a few seconds, a solid green LED indicates that the device has been successfully paired.
DO NOT PAINT
PUSH TO TEST / HUSH
10. Once the device is paired in the app, tap Done.
Pairing device with auto scan
Pairing the device with auto scan automatically discovers the device when the corresponding device is powered on.
1. Locate the power switch on the rear side of the device. Use a screwdriver to turn the power switch to ON position.
2. On the Home page, tap + > Auto scan > Confirm. 3. Enable permissions to Access location and Wi-Fi for scanning device and
tap Start scanning. NOTE: If you have multiple hubs, do Step 5 or proceed to Step 6.
4. Tap Select hub and select an ELKO SmartHUB from the slide-up menu. 5. Press the Setup/Reset button 3 times within 2 s and wait for a few seconds
until the device search is complete.. The LED blinks yellow.
TIP: If you want to pair multiple devices at once, perform step 5 on each device and wait for a few seconds for them to be detected. 6. Tap Next (A) and select Smoke Alarm.
Auto Scan Available devices found
Smoke Alarm

Next

A

7. Once the device is added successfully, tap Done.

DUG_Smoke Alarm AC_ELKO-00

9

ELKO – Smart Smoke Alarm 230 V
Setting up connection without ELKO SmartHUB
Interconnecting devices without ELKO SmartHUB
The smoke alarms (devices) can be connected directly to each other via RF connections even without a ELKO SmartHUB network.
IMPORTANT: Turn the power switch to ON position on all the devices. 1. Identify a device and mark it as Primary with a label supplied. Other devices
are considered as Secondary.
2. Short press the Test/Hush button 3 times within 2 s on the primary device.
3× < 2 s
The Standby LED turns on for 30 s once it is in pairing mode. 3. Identify a Secondary device and short press the Test/Hush button 3 times
within 2 s. The Standby LED blinks 3 times on both Primary and Secondary devices indicating a successful RF connection. Then on the Primary device, the Standby LED again turns on for 30 s Repeat the step 3 on all Secondary devices. NOTE: To exit from pairing mode, short press (< 0,5 s) the Test/Hush button 3 times on the Primary device. The Standby LED turns off indicating that the Primary device is not in pairing mode.

10

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Disconnecting a secondary device
Remove a Secondary device from the mounting base (See “Removing a device from the mounting base in the instruction manual”).
NOTE: · Do not remove the Primary device. · Read the following steps before disconnecting a Secondary device.
1. Make sure that the power switch is in OFF/AUTO position.
2. Press and hold the Test/Hush button and simultaneously turn the power switch to ON position.

The Standby LED turns on for 3 s.
3. Continue to hold the Test/Hush button until the Standby LED turns off. Then release the Test/Hush button.

4. Short press the Test/Hush button when the Standby LED is on for 3 s.
1× < 5 s

The Standby LED blinks for 5 s indicating disconnecting of RF interconnection also the Status LED blinks green for 7 times.
IMPORTANT:
· When the Secondary device is successfully disconnected, make sure to turn the power switch to OFF/ AUTO position.
· Test all smoke alarms for interconnection. Refer testing the interconnected device(s)

DUG_Smoke Alarm AC_ELKO-00

11

Testing the device

ELKO – Smart Smoke Alarm 230 V

The device has a test mode that helps ensure the proper operation of the device. It is recommended to test the device once a month. If the device is installed in a mobile home, it is recommended to test the device weekly and before every journey.
NOTE: Using ELKO Smart app you can set the monthly reminder for test alarm in settings, page 18.

Testing the individual device
IMPORTANT: Test the device once a month to ensure proper operation.
Press the Test/Hush button on each device for more than 3 s until an alarm sounds off. If the test alarm does not sound, then the device is not connected to power supply.

Testing the interconnected device(s)
It is possible to test all the devices simultaneously in an interconnected network with one operation.
1. Select any interconnected device. 2. Press and hold the Test/Hush button for more than 18 s until an alarm goes
off on all interconnected devices.
DO NOT PAINT

PUSH TO TEST /

1× > 18 s

If there is no alarm triggered on the interconnected devices, make sure that the wireless interconnection setup is correct. Also the distance between each device is within the specification.
NOTE: The triggered alarm on the interconnected devices remains for a longer time even if you release the Test/Hush button.

12

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Configuring the device
Changing the device icon
You can change the device icon using the ELKO Smart app. 1. On the Home page, select the device for which you wish to change the icon.
2. At the top-right corner of the screen, tap . 3. Tap edit next to the device name. 4. Tap Icon to view the menu. 5. In the slide-up menu, select any one of the following (A) to change the device
icon: ­ Take photo – allows you to take a photo with your device camera. ­ Select from Icon Library: allows you to select an icon from the app
library. ­ Select from Album: allows you to select a photo from the mobile gallery.

Icon Name Location

Take photo

Select from Icon Library

A

Select from album

Cancel

DUG_Smoke Alarm AC_ELKO-00

13

ELKO – Smart Smoke Alarm 230 V
Renaming the device
You can rename the device using the ELKO Smart app. 1. On the Home page, select the device for which you wish to rename. 2. At the top-right corner of the screen, tap . 3. Tap edit next to the device name. 4. Tap Name, enter the new name (A) and then tap Save.

Icon

Rename

Name LocationCancel

A
Save

Changing the device location

You can change the device location using the ELKO Smart app. 1. On the Home page, select the device for which you wish to change the location.

2. At the top-right corner of the screen, tap . 3. Tap edit next to the device name. 4. Tap Location. 5. Select the desired location from the list (A) and then tap Save.

Device location

Save

Living Room Master Bedroom Kitchen
A
Dining Room Study Room Kids Room

14

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Using the device
The Control Panel of the smoke alarm allows you to view the current state of the device and allow you to access the history and settings. On the Home page, tap All devices > Smoke Alarm to access the control panel. On the Smoke Alarm control panel page, you can see the following:
· Battery level (A) · Current state of the device (B) · History, page 16 (C) · Settings (D) : LED brightness settings, page 17 and Test alarm reminder,
page 18.
Smoke Alarm
A

B

No Alarm

C

History

D

Settings

DUG_Smoke Alarm AC_ELKO-00

15

ELKO – Smart Smoke Alarm 230 V
Checking the device history
Using the ELKO Smart app, you can monitor the smoke detection by accessing the device history.
1. On the Home page, tap All devices > Smoke Alarm. 2. On the device control panel page, tap History. 3. In the History page, you can see the date, time, and type of alarm detected.
History
The history supports record checking for 7 days in maximum. 04 February
04 February Smoke Alarm
19:46:02 I The Smoke Alarm occured Test Alarm 19:41:37 I The Test Alarm occured Test Alarm 19:41:22 I The Test Alarm occured
NOTE: The history supports record checking for 7 days maximum.

16

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Setting LED brightness
You can change the LED brightness to minimum and maximum manually or by using ELKO Smart app.
Changing the LED brightness manually
1. When the device is in standby mode, short press the test/hush button 3 times within 2 s.
3× < 2 s
2. When the Red LED is On, short press the Test/Hush button to switch between Min. and Max. LED brightness.
1× < 0,5 s
3. Again short press the Test/Hush button 3 times within 2 s to store the adjusted brightness level. Otherwise, you can wait 30s for the standby LED to turn off, then the brightness level will be saved.
3× < 2 s

DUG_Smoke Alarm AC_ELKO-00

17

ELKO – Smart Smoke Alarm 230 V

Changing the LED brightness using app

1. On the Home page, tap All devices > Smoke Alarm. 2. On the device control panel page, tap Settings. 3. Tap on LED Indicator Light Level (A). 4. Follow the settings mentioned in the pop-up notification, then tap Ok (B). 5. Select Min or Max indicator level (C).

Settings

A LED Indicator Light Level

Min

Test Alarm Reminder

Notice: you to take alarm test in every month if this function is on.

Settings

LED Indicator Light Level

Min

Test Alarm Reminder
Notice: you to take the alarm test in every month if this function is on.

Please press “Reset” key on the device to wake it up before applying the settings.

OFF/AUTO ON

Cancel

ok

B

LED Indicator Light Level
Min
C
Max
Cancel

Test alarm reminder

You can set a reminder for the test alarm in the ELKO Smart app. 1. On the Home page, tap All devices > Smoke Alarm. 2. On the device control panel page, tap Settings. 3. Tap the Test Alarm Reminder toggle switch (A) to turn on the reminder.

Settings

LED Indicator Light Level

Max

Test Alarm Reminder

A

Notice: If the Test Alarm Reminder is activated, the App will perform a test alarm. The reminder is also stored in the

NOTE: If the test alarm reminder is enabled, the app sends a monthly reminder to perform a test alarm on the first day of every month. The reminder is also stored in the Notification history under Messages.

18

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Silencing the device
Hush the smoke alarms
During an alarm event, first identify the smoke alarm/s that detected smoke, these will have Red LEDs blinking. Then short press the Test/Hush button on the device to stop the alarm.
IMPORTANT: In hush mode, the device will not detect smoke/high temperature for 10 minutes. After this time the device resumes to normal operation. During this time, the Standby LED blinks once every 8 s. For instance, if smoke is detected and the device is set to hush mode, hightemperature detection will still be active. or If high temperature is detected and then device is set to hush mode, smoke detection will still be active. In the event that smoke and high temperature are both detected at the same time, and the device is set to hush mode, then both smoke and high temperature detection will not work for the next 10 minutes. In an interconnected group, if more than one device has blinking Red LEDs and an active alarm, short press the Test/Hush button on all devices. All interconnected devices stop alarming within 5 to 10 s. NOTE: Wait for 10 minutes before performing any test to avoid malfunctioning of the device. Once the device is set to Hush Mode the status can be checked in ELKO Smart app.
Smoke Alarm
The device is in Hush Mode – it will not detect smoke temporarily.
Hush Mode
History Settings

DUG_Smoke Alarm AC_ELKO-00

19

ELKO – Smart Smoke Alarm 230 V
Temporarily disabling smoke detection
To temporarily disable the smoke detection of a device, short press the Test/Hush button once when the device is in Standby mode. The device will not detect smoke for 10 minutes. During this mode the Standby LED blinks once every 8 s.

NOTE: The temperature sensor remains active even when the smoke detection is disabled.

Snoozing the device alerts

Low Battery

When the battery is low, the Standby LED blinks every 48 s, together with a beep. You can snooze the low battery indication for 10 hours by short pressing the Test/ Hush button once.
IMPORTANT: The user must replace the device within 30 days after the first alert.

Fault detection

When a device fault is detected, 2 beeps occur every 48 s together with blinking Standby LED. You can snooze the indication for 10 hours by short pressing the Test/Hush button once. Refer troubleshooting, page 29.

Alarm memory

In an interconnected group, the Standby LED on the triggered device blinks once every 2 s for 72 hours after the alarm has stopped. This allows the user to identify the device that was triggered by smoke/high temperature. Short press the Test/ Hush button once to snooze the blinking LED for 10 hours.

False alarm

In an event of a false alarm in an interconnected group, it is recommended to identify the triggering device(s) by finding the devices with flashing Red LED every 2 s, or by using alarm history log in the app. These devices must be cleaned, serviced or replaced if necessary.

20

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Creating an automation
Automation allows you to group multiple actions that are usually done together, triggered automatically or at scheduled times. Using the ELKO Smart app, you can create automations based on your needs.
1. On the Home page, tap the . 2. Go to Automation > + to create an automation.
3. Tap Edit name , enter the name of the automation (A) and tap Save. TIP: You can choose the cover image that represents your automation by tapping .
Cancel Automation settings Save
My Automation

Any condition is met Edit name

(0/10)

Add Condition
A

Action Cancel

(ASdadvede 0/80)

Add Task

All-Day

4. Tap Any condition is met to select any one of the condition type (B): ­ All conditions are met- The automation is triggered when all the conditions are met. ­ Any condition is met- The automation is triggered when at least one condition is met.
Cancel Automation settings Save
My Automation

Any condition is met

(0/10)

Add Condition

Action

(Added 0/80) Add Task

Select Condition type
All conditions are met
B
Any condition is met
Cancel

5. Tap Add Condition to display the slide-up menu.

DUG_Smoke Alarm AC_ELKO-00

21

ELKO – Smart Smoke Alarm 230 V
6. In the Add Condition menu, you can do either or all of the following options (C): ­ When weather changes – Select the various weather settings ­ Schedule – Set the time and day ­ When device status changes – Select the device and it’s function
NOTE: You can add one or more conditions using . .
Cancel Automation settings Save
My Automation

Any condition is met

(0/10)

Add Condition

Add Condition

When weather changes

Schedule

C

When device status changes

7. Tap When device status changes > Smoke Alarm and select either or all of the functions to add in the automation: ­ Heat Alarm – When the device detects rise in temperature (D) ­ Test Mode – When the device is in test mode (E) ­ Remote Alarm – When the device is triggered by interconnected device (F) ­ Hush Mode – When the device is in hush mode (G) ­ Smoke Alarm – When the device detects smoke (H)
Select function
D Heat Alarm E Test Mode F Remote Alarm G Hush Mode H Smoke Alarm

8. Tap Add task to display the slide-up menu.

22

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
9. In the Add task menu, you can do either or all of the following options (I): ­ Run the device- Select the devices that you want to triggered. ­ Moment or Automation- Select the moment which you want to trigger or select the automation that you want to enable or disable. ­ Send notification- Turn On notification for the automation. ­ Delay – Set the delay time.
NOTE: You can add one or more actions using .
Cancel Automation settings Save
My Automation

Any condition is met

(0/10)

Add Condition

Action

(Added 0/80) Add task

Run the deAvdidceTask

Moment or Automation

All-Day

I

Delay

10. Tap on Effective period to set the time range for the automation. You can select any one of the following (J):
­ All-day – 24 hours ­ Daytime – From sunrise to sunset ­ Night – From sunset to sunrise ­ Custom – User defined time period

Next

All-day 24 hours

Daytime From sunrise to sunset

Night

J

From sunset to sunrise

Custom

Repeat City

Everyday

11. Set all the actions and conditions and than tap Save. Automation is now available under Automation tab. Use toggle switch to enable/disable automation.

DUG_Smoke Alarm AC_ELKO-00

23

ELKO – Smart Smoke Alarm 230 V
Example of an automation
This demonstration shows you how to create an automation to get notification on your app when the smoke is detected.
1. Go to Automation > + to create an automation.
2. Tap Edit name , enter the name of the automation and tap Save. TIP: You can choose the cover image that represents your automation by tapping .
3. Tap Add Condition > When device status changes > Smoke Alarm. 4. In Select function menu tap on Smoke Alarm > Smoke Alarm (A).
Smoke Alarm
Smoke Alarm Ended
A Smoke Alarm

5. Tap Add task > Send Notification and select Notifications (B).

Multiple items selectable

Next

B

6. Tap Next. 24

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
7. In the Automation Settings page, tap Save.
Cancel Automation settings Save
My Automation

Any condition is met

(1/10)

Smoke Alarm Smoke Alarm: Smoke Alarm

Action

(1/80) On

All-Day

Once the automation is saved, it is visible on the Automation tab. You can tap the toggle switch on the automation to enable it.
Push notification will appear on the screen when the automation is triggered. You can also tap on to access the notification history.
Editing an automation
To edit an automation: 1. On the Automation tab, locate the automation you want to edit and tap . 2. On the Edit page, you can tap each item (such as dimmer, shutter, delay, temperature, etc.) to change the settings. TIP: · You can add one or more actions using . · To delete an existing condition or action, slide each item towards left and tap Delete.
Deleting an automation
To delete an automation: 1. On the Automation tab, locate the automation that you want to delete and then tap . 2. Tap Delete and tap Ok. NOTE: After deleting an automation, the device action can no longer be triggered.

DUG_Smoke Alarm AC_ELKO-00

25

Removing the device from the app

ELKO – Smart Smoke Alarm 230 V

You can remove a device from the device list using the ELKO Smart app, To remove the device:
1. On the Home page, tap All devices > Smoke Alarm.

2. Tap to display more details. 3. Tap Remove and Factory Reset Device (A) and tap Confirm.

More Smoke Alarm
Room: Sensors Device information Moment and Automation
Others
FAQ & Feedback Add to home Screen
No updates available.

Remove and Factory Reset Device

A

TIP: Alternatively, you can tap and hold on theSmoke Alarm on the Home page to remove the device. NOTE: By removing the device, you will reset the device. If you still have a problem with the reset, then refer to resetting the device, page 26.
Resetting the device manually
Short press (< 0,5 s) the Setup/Reset button 3 times and then long press the Setup/Reset button once for >10 s to reset the device to factory default mode.
IMPORTANT: All configuration data, user data and network data are deleted.
ON OFF/AUTO

26

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Maintenance and cleaning
A monthly inspection is recommended to help ensure the device is dust, dirt, and insect free. The device can be vacuumed (strongly recommended) or brushed with a soft brush to remove accumulated dust, dirt or kitchen grease. Apply a small amount of insect surface spray to a cloth and wipe around device(s) every 3 to 6 months to mitigate insect ingress.
IMPORTANT: 1. Always test the device after cleaning, for more information refer testing the device, page 12. 2. If necessary refer to the installation instruction for more information about installing the device.
NOTICE
EQUIPMENT MAINTENANCE INSTRUCTIONS · Test the device regularly to ensure its functionality and the battery is in good
condition. · Replace the device after 10 years from the date of manufacturing. · Do not open the device casing or repair yourself. There are no serviceable
parts inside. Failure to follow these instructions can result in equipment damage.

DUG_Smoke Alarm AC_ELKO-00

27

LED Indications
Pairing
User Action Press the Setup/Reset button 3 times

ELKO – Smart Smoke Alarm 230 V

LED Indication Status LED blinks yellow, once per second.

Status
Pairing mode is active for 30 seconds. When pairing is completed, status LED glows green for some time before turning Off.

Resetting
User Action Press the Setup/Reset button 3 times and hold it for > 10 s.

LED Indication After 10 s, status LED starts blinking red.

Status
The device is in reset mode. It is reset to the factory settings after 10 seconds. The device then restarts and the status LED starts blinking green before turning Off.

Operating

Operating Mode

Normal mode / Standby mode

Alarm Mode

Local Alarm * Interconnected alarm

Test mode Wireless interconnection test

Hush mode Low battery mode Fault mode
Snooze Mode

Low battery Fault Alarm memory

Standby LED Blinks every 48 s Blinks every 1 s OFF 1 blink every 1 s
OFF
Blinks every 8 s Blinks every 48 s
2 blinks every 48 s
Blinks every 24 s 2 blinks every 24 s Blinks every 48 s

Alarming Sound OFF 3 beeps every 4 s 3 beeps every 4 s 3 beeps every 4 s
Continuous 3 beeps every 4 s OFF 1 beep every 48 s
2 beeps every 48 s
OFF OFF OFF

Duration — — —
Until Test/Hush button is released 25 s
10 min End of life: replace smoke alarm Until fault has been cleared 10 hrs 10 hrs 10 hrs

NOTE: For all the operating modes, LED blinks Red. * For local smoke alarms, all red LEDs blink, whereas, for local temperature alarms, only the standby red LED blinks.

28

DUG_Smoke Alarm AC_ELKO-00

ELKO – Smart Smoke Alarm 230 V
Troubleshooting

Issue Device does not produce an alarm sound when tested.
Device beeps and Standby LED blinks every 48 s Device beeps twice and Standby LED blinks every 48 s Device produces alarm sound unexpectedly without smoke or steam or high temperature.

Resolution/Action
1. Confirm that the power switch is in ON position, or the device is installed correctly. If you are unsure then remove and reinstall the device.
2. Press Test/Hush button until an alarm sound is produced. Do not press consecutively.
3. If the problem persists or if you have questions about the warranty, contact customer care center.
Battery may be low or drained. Replace the device.
1. Clean the device. Refer to Maintenance, page 27 section.
2. If the problem persists or if you have questions about the warranty, contact customer care center.
1. Identify the triggered device, indicated by a blinking Standby LED and 3 beeps every 4 s.
2. Press Test/Hush button to pause the alarm sound. The interconnected device stops alarming within 10 s.
3. Clean the device. Refer to Maintenance, page 27.
4. Reinstall the device and test.
5. If the problem persists or if you have questions about the warranty, contact customer care center.
IMPORTANT: After an alarm event, the device that has blinking Standby LED every 2 s is the triggered device. Identify the device and follow steps 3 to 5.

Technical Data
Power supply Back up battery Life Operating Current Sensing Type Operating Temperature Ambient Humidity Cable interconnection Wireless interconnection Terminal provisions
Operating frequency
Wireless Range Horn Level Mounting Type Dimensions (H × W × D) Standard Certification

110-240 VAC, 50 / 60 Hz 10 years 40 mA Photoelectric. This alarm contains NO radioactive material. 0 °C to 45 °C 5% to 95% Max. 40 devices RF+Zigbee, max. 40 devices in one network Active, Neutral, Loop and Interconnect terminals, each accommodates 2 × 1.5 mm² or 1 × 2.5 mm² Zigbee: 2405 – 2480 MHz RF: 868 MHz 40m indoor line of sight 85 dB at 3 m Mounting on ceiling only 115 × 115 × 46 mm EN 14604 Zigbee 3.0

DUG_Smoke Alarm AC_ELKO-00

29

Trademarks
This guide makes reference to system and brand names that are trademarks of their relevant owners.
· Zigbee® is a registered trademark of the Connectivity Standards Alliance. · Apple® and App Store® are brand names or registered trademarks of Apple Inc. · Google PlayTM Store and AndroidTM are brand names or registered trademarks
of Google Inc. · Wi-Fi® is a registered trademark of Wi-Fi Alliance®. Other brands and registered trademarks are the property of their respective owners.

ELKO AS Sandstuveien 68, 0680 Oslo Pb 6598 Etterstad, 0607 Oslo Norway
+47 67 79 39 00 support@elko.no www.elko.no
As standards, specifications, and design change from time to time, please ask for confirmation of the information given in this publication.
© 2023 ­ ELKO AS. All rights reserved. DUG_Smoke Alarm AC_ELKO-00

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals