cronte S4A Intelligent Automatic Flat Door System Instruction Manual

October 30, 2023
CRONTE

S4A Intelligent Automatic Flat Door System
Instruction Manual

Technical parameter

Power supply:200v~240v
Opening time:3~75/90″
Opening and holding time:1~30s
Temperature:-201C~+551
Protection level:IP12D
Product weight:6.5Kg
Product volume 515x95x80mm
1= Door width
kg= Door weight
Optimum scope
Limit range

Description of accessories

cronte S4A Intelligent Automatic Flat Door System -
Description

Mechanical installation

3.1 Installation example

cronte S4A Intelligent Automatic Flat Door System -
Description1

3.2 Baseboard installation

cronte S4A Intelligent Automatic Flat Door System -
Description2

3.2 Baseboard installation

cronte S4A Intelligent Automatic Flat Door System -
Description3

3.3 Pull arm mounting

cronte S4A Intelligent Automatic Flat Door System -
Setting

3.4 Puts Arm Installation

cronte S4A Intelligent Automatic Flat Door System -
Setting1

According to the different depth L of the door frame. tre length of the push arm can be adjusted by loosening three clamping bolts, 50 thal the angle between the push arm and the door body is 90 degrees as snown in the figure
Installation on the right side of automatic docr

cronte S4A Intelligent Automatic Flat Door System -
Setting2

3.5 Driver system installation

cronte S4A Intelligent Automatic Flat Door System -
Setting3

Install the drive system as shown it the illustration on the installed base plate, will eight hexagon socked heads screwed
3.7 Drive system and pull arm connection

cronte S4A Intelligent Automatic Flat Door System -
Setting4

Electrical connections

cronte S4A Intelligent Automatic Flat Door System -
Setting5

Double door synchronization
cronte S4A Intelligent Automatic Flat Door System -
Setting6 In the double opening door. the first opening and the second closing are sel as the alcove ones. and the rear opening is first sell as the driven door, the active door K2 is set, and the driven door K2 is placed.
Sensor, access control and alcove doer controller connection

cronte S4A Intelligent Automatic Flat Door System -
Setting7

Note: When two doars share one sensor or the same source, the double door may open normally. Al this point, change the o signal lines of the sensor on one of the controllers 1o restore normal operation.

Parameter adjustment

cronte S4A Intelligent Automatic Flat Door System - Parameter
adjustment

1. Remote leering Litton
2. opening speed
3. Buffer angle of opening door
4. Closing speed
5. Buffar angle of closing door
6. hold open time
7. Reserved function key| Clockwise speed s gelling faster
Increased clockwise angle
Clockwise speed is getting faster
Increased clockwise angle
Time Is longer In clockwise direction
About 7 seconds at 14 position
About 14 seconds in 12 position
Afoul 21 seconds i 34 position
---|---

Switch salting (Ki – After sating. power off, restart is affective
KA1 When the power is turned on., in the initial state, the door moves to the correct position in the direction of closing the door, and if it moves in the direction of opening the toor, the switch position is changed
K2: When the double door is synchronized, the active door is placed and the driven door is placed (on)
K3 Choose PUSH arm or PULL arm
Ka: The door is opened and the forbidder force is placed (on)
remote contral

cronte S4A Intelligent Automatic Flat Door System - Parameter
adjustment1

Controller and controller pair code description

  1. Empty: Pross and hold that “Remora easing Key® button 1o know that you can’ U hear the buzzer sound and release (he button
  2. Pair code: Press the “Remold Learning Key” button and the buzzer will sound. At this fame. press any button on the remote control, and the buzzer will beeps tree times, Indicating that the code s successful T ne buzzer wil beep when using the remote Gontram
  3. Note: When using the remote control, the buzzer will beep twice, indicating that the remote control and the controller are not successfully coded. Please repeal item 2
  4. Press the ~inching busier button, the door swift once

Product Quality Assurance / Certificate

  1. Under normal conditions of use. due to defects in the manufacture of the product itself, free after sales service can be obtained during the quality assurance period.
  2. if there is a problem. please contact our company.
  3. In the following cases. after sales service is provided in the form of paid maintenance even if the product is in the quality assurance period. Malfunctions caused by inadvertent or unsuitable installation. repair. and modification by the user; failures caused by the user not following the items specified in the instruction manual
  4. Please show the quality guarantee and purchase invoice when maintenance is required.
  5. Since the company does not reissue the quality guarantee. one machine and one card, please keep it in a safe place.

Certificate
Product name _Intelligent Automatic Door System model…………………………..
Manufacturing model……………………………………
inspector……………………………………………………
Manufacturing date……………………………………..

Product name Intelligent Automatic Door System| Guarantee period|
---|---|---
model|  | One year
SER.NO|
Purchase date| year month date|  |
Guarantee period| year month date|  | To year month
User address|
user name|  | telephone number

Note:

  1.  The construction shop should provide customers with one-year warranty and abler sales service, that is. the construction shop should be stamped.
  2. The wearing purls are not covered by the warranty

F: ()
Consumer consultation
China Branch

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals