Recommended wiring: 18/6 shielded for main device, and 18/4 shielded for optional Wiegand devices.
Items Included in Kit
- Watchman Unit
- 12 Volt DC Power Supply
- Magnetic Read Switch
- Leave one key with the customer
- Nuts X 4
- Bolts X 4
- Quick Install Guide
- Activation & Test Process
- Customer Information Packet
Watchman Unit
Power Supply Wiring
Interface Circuit Board (Oriented the same as the Watchman install)
- 18 ga stranded: up to 25 ft.
- 16 ga stranded: up to 50 ft.
- 12 ga stranded: up to 60 ft.
Interface Wiring Diagram
Oriented the same as the Watchman install
6-Wire Installation Instructions
- Wire main power from the transformer to the power connector on the circuit board.
- Connect gate trigger wires from the Normally Open (NO) and Common (C) to the free-exit or exit terminals on the gate operator.
- Connect the gate status wires on the 6 pin connector on the main relay and input plug to the magnetic switch or a Dry Contact, Normally Closed (NC) relay on the gate operator.
- If using an optional 26-bit reader (e.g., keypad, card reader, RFID, clicker), wire the device to the Wiegand connection on the interface circuit board.
- Use Camera Guide if adding external camera.
- Test and activate using the test credentials on the Activation & Test Process document.
Place the Mag Switch anywhere you can pull A and B at least 2 inches away from each other when the gate is open, and where you can pull A and B 1.5 inches apart when the gate is open.
Note: Gate statuses can be inverted. If needed, please cell Cellgate to invert.