cellgate W410 Perimeter Security Group Installation Guide

May 15, 2024
Cellgate

cellgate Logo Your Virtual Security Guard
410 Quick Install Guide

CellGate Support: 972-231-1999, opt. 3

Items Included in Kit

  1. W410 Unit

  2. 12 Volt DC Power Supply

  3. Magnetic Read Switch

  4. Keys

  5. Nuts x 4
    NOTE Leave one key with the customer.

  6. Bolts x 4

  7. Quick Install Guide

  8. Activation & Test Process

  9. Customer Information Packet

cellgate W410 Perimeter Security Group - Circuit Board **** Recommended wiring: 18/6 shielded for main device, and 18/4 shielded for optional Wiegand devices.

Interface Circuit Board

cellgate W410 Perimeter Security Group - Circuit BoardThe circuit board is oriented the same as the Watchman install.
We recommend the following gauges (ga) for each distance:

  • 18 ga stranded: up to 25 ft
  • 16 ga stranded: up to 50 ft
  • 12 ga stranded: up to 60 ft

Interface Wiring Diagram (Oriented the same as the Watchman install)

** The supplied diode must be used for all magnetic lock installations, or the warranty is voided.
18 Gauge Wire Minimum for Install
cellgate W410 Perimeter Security Group - Main Power
6-Wire Installation Instructions**

  1. Wire main power from the transformer to the power connector on the circuit board.
  2. Connect gate trigger wires from the Normally Open (NO) and Common (C) to the free-exit or exit terminals on the gate operator.
  3. Connect the gate status wires on the 6-pin connector on the main relay and input plug to the magnetic switch or a Dry Contact, Normally Closed (NC)  relay on the gate operator.
  4. If using an optional 26-bit reader (e.g., keypad, card reader, RFID, clicker), wire the device to the Wiegand connection on the interface circuit board.

Wiring with Transformer

cellgate W410 Perimeter Security Group - Wiring with
Transformer Wiring for Solar Power

cellgate W410 Perimeter Security Group - Wiring for Solar
Power Dry Contact Relay, Normally Open Dry Contact
No Voltage to Lock or Gatecellgate W410 Perimeter Security Group - Dry
Contact Dry Contact Relay, Normally Closed Dry Contact
No Voltage to Lock or Gatecellgate W410 Perimeter Security Group - Closed
Dry Contact Lock Requiring Constant 12 V: Wet Contact Relay, Normally Open
Door/lock opens (releases) when power is added.

cellgate W410 Perimeter Security Group - Contact Relay Lock Requiring Constant 12 V: Wet Contact Relay, Normally Closed
Door/lock opens (releases) when power is removed.cellgate W410 Perimeter
Security Group - Lock Requiring Constant Wiegand Wiring to Board and Direct to Faceplate, 26 Bit Reader
To Interface Boardcellgate W410 Perimeter Security Group - Bit
Reader

Wiring Standards
Positive:
White
Negative: Gray
Normally Open (NO): Blue
Common: Brown
Positive Power (when live): Red
Ground: Black
Wiegand 1: Green
Wiegand 0: Greencellgate W410 Perimeter Security Group -
CenterThe Mag Switch can be placed anywhere that allows A and B to be pulled at least 2 inches away from each other when the gate is open and within 1.5 inches when the gate is closed.cellgate W410
Perimeter Security Group - Gate Closed

NOTE Gate statuses can be inverted. If needed, please cell CellGate to invert.

Optional External Camera Wiring Diagram

**** Do not make electrical connections to camera with the system energized. This will damage the camera and is not covered under the camera warranty.
18 Gauge Wire Minimum for Installcellgate W410 Perimeter Security Group -
Ethernet Connector

cellgate Logo1.855.694.2837
cell-gate.com
2023

Documents / Resources

| cellgate W410 Perimeter Security Group [pdf] Installation Guide
W410 Perimeter Security Group, W410, Perimeter Security Group, Security Group, Group
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals