cellgate W410 Perimeter Security Group Installation Guide
- May 15, 2024
- Cellgate
Table of Contents
Your Virtual Security Guard
410 Quick Install Guide
CellGate Support: 972-231-1999, opt. 3
Items Included in Kit
-
W410 Unit
-
12 Volt DC Power Supply
-
Magnetic Read Switch
-
Keys
-
Nuts x 4
NOTE Leave one key with the customer. -
Bolts x 4
-
Quick Install Guide
-
Activation & Test Process
-
Customer Information Packet
**** Recommended wiring: 18/6 shielded for main device, and 18/4 shielded for optional Wiegand devices.
Interface Circuit Board
The circuit board is oriented the same as the Watchman install.
We recommend the following gauges (ga) for each distance:
- 18 ga stranded: up to 25 ft
- 16 ga stranded: up to 50 ft
- 12 ga stranded: up to 60 ft
Interface Wiring Diagram (Oriented the same as the Watchman install)
** The supplied diode must be used for all magnetic lock installations, or
the warranty is voided.
18 Gauge Wire Minimum for Install
6-Wire Installation Instructions**
- Wire main power from the transformer to the power connector on the circuit board.
- Connect gate trigger wires from the Normally Open (NO) and Common (C) to the free-exit or exit terminals on the gate operator.
- Connect the gate status wires on the 6-pin connector on the main relay and input plug to the magnetic switch or a Dry Contact, Normally Closed (NC) relay on the gate operator.
- If using an optional 26-bit reader (e.g., keypad, card reader, RFID, clicker), wire the device to the Wiegand connection on the interface circuit board.
Wiring with Transformer
Wiring for Solar Power
Dry Contact Relay,
Normally Open Dry Contact
No Voltage to Lock or Gate Dry Contact Relay, Normally
Closed Dry Contact
No Voltage to Lock or Gate Lock Requiring Constant 12
V: Wet Contact Relay, Normally Open
Door/lock opens (releases) when power is added.
Lock Requiring Constant 12 V: Wet Contact Relay, Normally
Closed
Door/lock opens (releases) when power is removed. Wiegand Wiring to Board and Direct to Faceplate, 26 Bit
Reader
To Interface Board
Wiring Standards
Positive: White
Negative: Gray
Normally Open (NO): Blue
Common: Brown
Positive Power (when live): Red
Ground: Black
Wiegand 1: Green
Wiegand 0: GreenThe Mag Switch can be placed anywhere
that allows A and B to be pulled at least 2 inches away from each other when
the gate is open and within 1.5 inches when the gate is closed.
NOTE Gate statuses can be inverted. If needed, please cell CellGate to invert.
Optional External Camera Wiring Diagram
**** Do not make electrical connections to camera with the system energized.
This will damage the camera and is not covered under the camera warranty.
18 Gauge Wire Minimum for Install
1.855.694.2837
cell-gate.com
2023
Documents / Resources
|
cellgate W410 Perimeter Security
Group
[pdf] Installation Guide
W410 Perimeter Security Group, W410, Perimeter Security Group, Security Group,
Group
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>