  • Q: What should I do if my SIM card needs a PIN to unlock?
    • A: Enter your PIN on the pop-up page and click Save & Apply. Wait for 15 seconds for the Internet connection to establish.
  • Q: How do I know if my internet connection is successful?
    • A: Check the cellular information card on the status page. If the status shows as connected, it means the internet connection is successful.
  • Q: What should I do if I encounter issues with APN parameters or any other problems?
    • A: Contact your internet provider for APN parameters or reach out to our technical support team at support@cudy.com for assistance.

Quick Installation

  1. Install the cellular antennas.
  2. With the gold contacts facing down, gently slide the nano SIM card into the SIM1 slot until you hear a click sound.
    • Note 1: The router doesn’t support SIM hot-swapping. You need insert or remove the SIM card while the router is powered off, otherwise they may get damaged.
    • Note 2: If both SIM1 and SIM2 card slots are inserted with SIM cards, the router will automatically choose which SIM card to use. Since the automatic selection mechanism is time-consuming, it is highly recommended to insert only one SIM card when using for the first time.
  3. Connect the power adapter to the router.
  4. Turn on the router. Waiting 2~5 minutes for it to start.
  5. Check the status of the LED.
    • When the LED turns solid blue or purple, it means the router is connected to the cellular network.
    • If the LED turns to solid red, please follow the instructions of Customize the Router.

Note

  • For some ISP’s SIM card (such as Verizon), it may take longer to connect to the Internet. Please kindly wait another 2~5 minutes.

Customize The Router

  1. Connect the router via Ethernet cable or Wi-Fi. Network name and password is printed on the bottom of the router.
  2. Launch a web browser and enter http://cudy.net/ (or http://192.168.10.1/) in the address bar, use admin as password to login.
  3. The page below would pop up if your SIM card needs PIN to unlock. Please enter your PIN and click Save & Apply, then wait 15 seconds to connect to the Internet.
  4. Then please check cellular information card of the status page. If the status is connected, it means the internet connection is successful.
  5. If the Internet is not connected, or you want to customize the router yourself, click “Quick Setup” and follow the step-by-step instructions to configure the router.

Note

  1. If you are not sure about APN parameters, please contact your internet provider.
  2. If you meet any other problems, don’t hesitate to contact our technical support team: support@cudy.com
  3. Frequently Asked Questions: https://www.cudy.com/faq

Enjoy the internet!

LED And Button

How to upgrade firmware

  1. Download the latest firmware from https://www.cudy.com/download
  2. Unzip the file you download
  3. Connect to Cudy’s network via WiFi or Ethernet.
  4. Open a web browser and go to http://cudy.net/ or http://192.168.10.1/
  5. Log into the web management page.
  6. Click Advanced Settings -> Firmware.
  7. Choose the firmware you unzipped to upload.
  8. Waiting 2~5 minutes for the router to restart.
  9. Done

FCC Statements

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the followingmeasures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other
antenna or transmitter. End-users and installers must be provided with antenna installation instructions and consider removing the no-collocation statement.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference.
  2. this device must accept any interference received, including interference that may cause undesired operation.

Caution

  • Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

EU Declaration of Conformity

  • Cudy hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/53/EU, 2009/125/EC and 2011/65/EU.
  • The original EU declaration of conformity may be found at http://www.cudy.com/ce.

Regulatory Compliance_P5

FCC compliance information statement

  • Product name: 5G SA/NSA AX3000 Wi-Fi 6 Router
  • Model Number: P5
Component Name Model
I.T.E. Power Supply GQ24-120250-AU
  • Responsible party: Shenzhen Cudy Technology Co., Ltd.
  • Address: Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan 67 District, Shenzhen, China
  • Website: https://www.cudy.com
  • Tel: +86 755 8600 8993
  • Email:support@cudy.com

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note

  • The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
  • Such modifications could void the user’s authority to operate the equipment.

FCC RF Radiation Exposure Statement

This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter.
‘To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.’

We, Shenzhen Cudy Technology Co., Ltd., has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.

FCC compliance information statement

  • Product Name: I.T.E. Power Supply
  • Model Number: GQ24-120250-AG
  • Responsible party: Shenzhen Cudy Technology Co., Ltd.
  • Address: Room A606, Gaoxinqi Industrial Park, Liuxianyi Road, Baoan 67 District, Shenzhen, China
  • Website: https://www.cudy.com
  • Tel: +86 755 8600 8993
  • Email:support@cudy.com

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
We, Shenzhen Cudy Technology Co., Ltd., has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.

CE Mark Warning

  • This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

Operating Frequency (Maximum transmitted power)

  • 2400 MHz – 2483.5 MHz: 20dBm
  • 5150 MHz – 5250 MHz: 23dBm
  • 5250 MHz – 5350 MHz: 23dBm
  • 5470 MHz – 5725 MHz: 30dBm

5G NR Standalone and Non-Standalone:

  • n1/n3/n5/n7/n8/n20/n28/n40/n71/n75/n76 (23dBm±2.7dB)
  • n38 (26dBm±2.7dB)
  • n41/n77/n78 (29dBm±2.7dB)
  • LTE: B1/B3/B5/B7/B8/B20/B28/B32/B40/B71 (23dBm±2.7dB)
  • B38/B41/B42/B43 (26dBm±2.7dB)

Frequency band 5150 – 5250 MHz:

Indoor use: Inside buildings only. Installations and use inside road vehicles and train carriages are not permitted. Limited outdoor use: If used outdoors, equipment shall not be attached to a fixed installation or to the external body of road vehicles, a fixed infrastructure or a fixed outdoor antenna. Use by unmanned aircraft systems (UAS) is limited to within the 5170 – 5250 MHz band.

Frequency band: 5250 – 5350 MHz:

  • Indoor use: Inside buildings only. Installations and use in road vehicles, trains and aircraft are not permitted. Outdoor use is not permitted.

Frequency band: 5470 – 5725 MHz:

  • Installations and use in road vehicles, trains and aircraft and use for unmanned aircraft systems (UAS) are not permitted.

EU Declaration of Conformity

Cudy hereby declares that the device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU, directive 2011/65/EU, directive (EU) 2015/863.
The original EU Declaration of Conformity can be found at http://www.cudy.com/ce

RF Exposure Information

  • This device meets the EU requirements (2014/53/EU Article 3.1a) on the limitation of exposure of the general public to electromagnetic fields by way of health protection.
  • The device complies with RF specifications when the device is used at 20 cm from your body.

National Restrictions

  • Attention: This device may only be used indoors in all EU member states and EFTA countries, and Northern Ireland.

UKCA Mark

Attention: This device may only be used indoors in Great Britain.

Canadian Compliance Statement

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Caution:

  • The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.
  • For devices with detachable antenna(s), the maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall be such that the equipment still complies with the e i.r.p. limit;
  • For devices with detachable antenna(s), the maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate.

Radiation Exposure Statement:

  • This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment.
  • This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

Industry Canada Statement

  • CAN ICES-3 (B)/NMB-3(B)

Safety Information

  • Keep the device away from water, fire, humidity or hot environments.
  • Do not attempt to disassemble, repair, or modify the device.
  • Do not use damaged charger or USB cable to charge the device.
  • Do not use any other chargers than those recommended.
  • Do not use the device where wireless devices are not allowed.
  • Adapter shall be installed near the equipment and shall be easily accessible.
  • Operation Temperature: 0° C to +45° C
  • Use only power supplies which are provided by manufacturer and in the original packing of this product. If you have any questions, please don’t hesitate to contact us.
  • This product uses radios and other components that emit electromagnetic fields.

Electromagnetic fields and magnets may interfere with pacemakers and other implanted medical devices. Always keep the product and its power adapter more than 15 cm (6 inches) away from any pacemakers or other implanted medical devices. If you suspect your product is interfering with your pacemaker or any other implanted medical device, turn off your product and consult your physician for information specific to your medical device.

Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.

Explanations of the symbols

Explanations of the symbols on the product label

Note: The product label can be found at the bottom of the product and its I.T.E. power supply.
Symbols may vary from products.

Need help

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals