AMTC HSM-801 SIDEMOUNT for Urinals and Toilets Instruction Manual

June 13, 2024
AMTC

AMTC HSM-801 SIDEMOUNT for Urinals and Toilets

Product Information

  • Product Name: HSM-801 Series
  • Product Type: Sidemount for Urinals and Toilets
  • Installation and Operation Manual: Included
  • User Approaches: The product senses when a user approaches and flushes automatically when the user leaves.
  • Power Source: Four (4) C Cell Alkaline Batteries (Factory Installed)
  • Additional Features: Collar Gasket, Battery Compartment, Wrench

Product Usage Instructions

Installation

  1. Before installation, it is recommended to shut off the water supply at the stop (not necessary but recommended).
  2. Using the supplied collar wrench, loosen the handle from the flush valve.
  3. Remove the handle from the flush valve (be prepared to collect any dripping water with a rag or towel).
  4. Tighten the collar nut using the supplied collar wrench.

Battery Installation

  1. Using the supplied battery compartment wrench, remove the side cover.
  2. Plug in the battery connector.
  3. Reinstall the side cover using the battery compartment wrench.

Adjusting Sensor Distance

  1. Press and hold the electronic push button until you see a blinking red LED in the sensor window (the unit will flush once).
  2. Release the electronic push button, wait one second, then press and release the electronic push button again. The unit will go into setup mode.
  3. While in setup mode, stand at the desired distance from the sensor (the red LED will continuously blink as long as you are within the allowed sensor range).
  4. Remain at the desired distance until the red LED becomes solid (the unit will flush once).
  5. The sensor distance is now locked at the new setting.
Adjusting Modes of Operation

Mode Adjustment Guide:

Switch #1 Switch #2 Switch #3
Water Saver Mode 24-Hour Ghost Flush Mode Flush Delay Mode
OFF – Standard flush mode OFF – Ghost flush mode is off OFF – 3-second flush

delay before flush (ideal for toilet)
ON – Flushes every other user for water savings (for use on
urinal only)| ON – Ghost flush mode is on (flushes once every 24 hours after
last use)| ON – No flush delay before flush (ideal for urinal)

Battery Replacement

  1. Using the supplied battery compartment wrench, remove the side cover.
  2. Slide out the battery tray and disconnect the battery connector.
  3. Remove the old batteries from the tray and load new batteries (note the position of the batteries in the tray).
  4. Reinstall the battery tray into the unit and reconnect the battery connector.
  5. Reinstall the side cover using the battery compartment wrench.

Troubleshooting

Problem: Fixture falsely activates. Constant blinking red LED.

Cause: Sensor distance may be set too far and registering the opposite wall or door as a user. Batteries need replacing.

Problem: Not enough water to fixture or too much water to fixture. Valve will not operate.

Cause: Diaphragm damaged. Valve control stop improperly adjusted. Sensor range may be set too close. Batteries are drained. Water supply is turned off. Relief valve (diaphragm plunger) is damaged.

HYBRIDFLUSH®
SIDEMOUNT for Urinals and Toilets
Installation and Operation Manual

AMTC-HSM-801-SIDEMOUNT-for-Urinals-and-Toilets-1

The HYBRIDFLUSH® sends out an infrared beam that senses a user on a urinal or toilet. Once the user walks away from the fixture the unit triggers the fixture to flush automatically. The unit’s unique design includes two manual flush buttons (one electronic and one mechanical) to allow for a courtesy manual flush option and for continuous manual activation when batteries are drained.

HYBRIDFLUSH® Components

AMTC-HSM-801-SIDEMOUNT-for-Urinals-and-Toilets-2

Installation

Pre-Installation Note:
Although not necessary, it is recommended to shut off water supply at stop.

  • A Using the supplied collar wrench, loosen handle from flush valve.

  • B Remove handle from flush valve.
    Note: A small amount of water may drip out while removing handle so be prepared to collect it with a rag or towel.

  • C Place collar gasket into collar nut and attach the HYBRIDFLUSH® unit where the handle was removed.

  • D Tighten collar nut using the supplied collar wrench.
    Note: Save removed handle in case you need to reuse for service of HYBRIDFLUSH® unit.

AMTC-HSM-801-SIDEMOUNT-for-Urinals-and-Toilets-3

Activation

Note: Four (4) “C” Cell batteries are factory installed inside the HYBRIDFLUSH® unit. The unit is shipped from factory with battery tray unplugged and must be plugged in to activate.

To activate the HYBRIDFLUSH® unit:

  • A – Using supplied battery compartment wrench, remove side cover.
  • B – Plug in battery connector.
  • C – Reinstall side cover using battery compartment wrench.
    Note: The HYBRIDFLUSH® unit comes preset from the factory. If special circumstances require adjustments, see STEP 4 “Adjusting Sensor Distance” and/or see STEP 5 “Adjusting Modes of Operation”.

Adjusting Sensor Distance

  • A – Press and hold electronic push button until you see a blinking red LED in sensor window (unit will flush once).
    Release electronic push button, wait one second, then press and release electronic push button once again.
    Unit will go into setup mode.

  • B – While in setup mode, stand at desired distance (red LED will continuously blink as long as you are within the allowed sensor range).

  • C – Remain at desired distance until red LED becomes solid (unit will flush once).
    Sensor distance is now locked at the new setting.

AMTC-HSM-801-SIDEMOUNT-for-Urinals-and-Toilets-5

Adjusting Modes of Operation

The HYBRIDFLUSH® unit includes different modes of operation. Remove side cover using battery compartment wrench and refer to the “Mode Adjustment Guide” for switch settings (see diagram below).The “Mode Adjustment Guide” can also be found on the inside of side cover for your convenience.

Mode Adjustment Guide

  • Switch #1: Water Saver Mode
    • OFF – Standard flush mode
    • ON – Flushes every other user for water savings (for use on urinal only)
  • Switch #2: 24-Hour Ghost Flush Mode
    • OFF – Ghost flush mode is off
    • ON – Ghost flush mode is on (flushes once every 24 hours after last use)
  • Switch #3: Flush Delay Mode
    • OFF – 3-second flush delay before flush (ideal for toilet)
    • ON – No flush delay before flush (ideal for urinal)

AMTC-HSM-801-SIDEMOUNT-for-Urinals-and-Toilets-6

Battery Replacement

  • Using supplied battery compartment wrench, remove side cover.
  • Slide out battery tray and disconnect battery connector.
  • Remove old batteries from tray and load new batteries (note position of batteries in tray).
  • Reinstall battery tray into unit and reconnect battery connector.
  • Reinstall side cover using battery compartment wrench.

AMTC-HSM-801-SIDEMOUNT-for-Urinals-and-Toilets-7

Visual Indicator Guide

  • Red LED – Constant blinking red LED indicates batteries are low and need replacing.
  • Electronic Push Button – Allows manual activation of flush when needed.
  • Mechanical Push Button – Allows manual activation of flush when needed and when batteries are drained.

AMTC-HSM-801-SIDEMOUNT-for-Urinals-and-Toilets-8

Troubleshooting Guide

PROBLEM CAUSE SOLUTION

Fixture falsely activates. Constant blinking red LED.

Not enough water to fixture or too much water to fixture.

Valve will not operate.

Valve does not shut off.

Valve does not flush even after sensor has been adjusted.

| Sensor distance may be set too far and registering the opposite wall or door as a user. Batteries need replacing.

Diaphragm damaged.

Valve control stop improperly adjusted. Sensor range may be set too close.

Batteries are drained.

Water supply is turned off.

Relief valve (diaphragm plunger) is damaged.

Dirt or debris preventing diaphragm from functioning properly.

Batteries are drained.

| Adjust sensor distance

(see STEP 4 “Adjusting Sensor Distance”).

Replace batteries

(see STEP 6 “Battery Replacement”). Replace diaphragm.

Adjust valve control stop.

Adjust sensor. Replace batteries. Turn water on.

Replace relief valve (diaphragm plunger). If the unit does not begin to function, call customer service at 1-800-874-7822.

Remove dirt or debris on diaphragm. Replace Diaphragm.

Replace batteries.

If the unit does not begin to function, call customer service at 1-800-874-7822.

Parts List

AMTC-HSM-801-SIDEMOUNT-for-Urinals-and-Toilets-9

Ref. # Part # Description
1 HSM-AA HYBRIDFLUSH Sidemount Actuator Assembly
2 HSM-BT HYBRIDFLUSH Sidemount Battery Tray
3 HSM-SCA HYBRIDFLUSH Sidemount Side Cover Assembly
4 HSM-SCS HYBRIDFLUSH Sidemount Side Cover Screw

WARRANTY

AMTC WARRANTS ITS PRODUCTS TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF FIVE (5) YEARS FROM DATE OF PURCHASE, WHEN PROPERLY INSTALLED AND UNDER NORMAL USE AND SERVICE. THESE PROVISIONS DO NOT INCLUDE THE BATTERIES SHIPPED WITH THE PRODUCTS. A DEFECTIVE PRODUCT MAY BE RETURNED TO AMTC OR ITS AUTHORIZED REPRESENTATIVES WITHIN FIVE (5) YEARS FROM DATE OF PURCHASE WITH THE PROPER INVOICE OF PURCHASE. AMTC AT ITS DISCRETION WILL REPLACE OR REPAIR DEFECTIVE PRODUCT AT NO CHARGE. CLAIMS FOR LABOR, TRANSPORTATION, AND ANY OTHER INCIDENTAL COSTS WILL NOT BE ALLOWED. AMTC WILL NOT BE RESPONSIBLE FOR ANY CONSIDERABLE DAMAGES OF ANY KIND WHATSOEVER.

FOR TECHNICAL SUPPORT PLEASE CALL TOLL FREE 1-800-874-7822 OR VISIT OUR WEBSITE AT WWW.AMTCORPORATION.COM
MAKE SURE TO VISIT OUR WEBSITE PERIODICALLY FOR INFORMATION ON NEW PRODUCTS AND TO DOWNLOAD ANY IMPORTANT PRODUCT DOCUMENTS THAT YOU MAY NEED IN THE FUTURE.

Advanced Modern Technologies Corporation
8367 Canoga Avenue, Canoga Park, CA 91304
Tel: 818-883-2682 Toll Free 800-874-7822 Fax: 818-883-2620
www.amtcorporation.com

Copyright © 2023 Advanced Modern Technologies Corporation The information contained in this document is subject to change without notice.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals