AL-KO Drain 10000 Inox Submersible Pump Instruction Manual

October 30, 2023
AL-KO

AL-KO Drain 10000 Inox Submersible Pump

Product Information

The DRAIN 10000, DRAIN 12000, DRAIN 10000 INOX, and DRAIN 15000 INOX are different models of submersible pumps.

  • DRAIN 10000 (Art.Nr. 112 825) has a power of 650 W and weighs 5.7 kg.
  • DRAIN 12000 (Art.Nr. 112 826) has a power of 850 W and weighs 6.9 kg.
  • DRAIN 10000 INOX (Art.Nr. 112 827) has a power of 750 W and weighs 6.7 kg.
  • DRAIN 15000 INOX (Art.Nr. 112 828) has a power of 1100 W and weighs 6.8 kg

These pumps operate on a voltage of 230V AC/50 Hz and come with
an attached power cable with a plug. The pumps have different
maximum flow rates and can pump liquids up to a certain height:

  • DRAIN 10000: maximum flow rate of 10000 l/h, maximum pumping height of 8 m.
  • DRAIN 12000: maximum flow rate of 12000 l/h, maximum pumping height of 10 m.
  • DRAIN 10000 INOX: maximum flow rate of 10000 l/h, maximum pumping height of 9 m.
  • DRAIN 15000 INOX: maximum flow rate of 15000 l/h, maximum pumping height of 11 m.

Product Usage Instructions

Identify the model of your submersible pump using the type label provided with the product. Follow the steps below to use the  pump:

  1. Place the pump in the liquid to be pumped. Ensure that the pump is fully submerged in the liquid.
  2. Connect the power cable to a power outlet.
  3. Ensure that the float switch (if present) is not obstructed and can move freely.
  4. Switch on the pump using the power switch (if present).
  5. The pump will start pumping the liquid. Ensure that the liquid is being pumped out through the discharge hose.
  6. Monitor the pump and ensure that it is operating smoothly. If any issues are observed, switch off the pump immediately and consult the user manual for troubleshooting tips.
  7. Switch off the pump once the liquid has been completely pumped out or as required.
  8. Disconnect the power cable from the power outlet and remove the pump from the liquid.
  9. Clean and store the pump in a dry location as instructed in the user manual.

DRAIN 10000 / DRAIN 12000

AL-KO-Drain-10000-Inox-Submersible-Pump-3

DRAIN 10000 INOX / DRAIN 15000 INOX

AL-KO-Drain-10000-Inox-Submersible-Pump-6

| DRAIN 10000 (Art.Nr. 112 825)
DRAIN 12000 (Art.Nr. 112 826)| DRAIN 10000 INOX (Art.Nr. 112 827)
DRAIN 15000 INOX (Art.Nr. 112 828)
---|---|---
| DRAIN 10000 650 W
DRAIN 12000 850 W| DRAIN 10000 INOX 750 W
DRAIN 15000 INOX 1100 W
| 230 V AC/50 Hz| 230 V AC/50 Hz
| X 8| X 8
| 5 m| 5 m
| DRAIN 10000 8 m
DRAIN 12000 10 m| DRAIN 10000 9 m
DRAIN 15000 11 m
| DRAIN 10000 10000 l/h
DRAIN 12000 12000 l/h| DRAIN 10000 10000 l/h
DRAIN 15000 15000 l/h
| 35 °C| 35 °C
| 10 cm| 9,5 cm
| 30 mm| 30 mm
| DRAIN 10000 5,7 kg
DRAIN 12000 6,9 kg| DRAIN 10000 INOX 6,7 kg
DRAIN 15000 INOX 6,8 kg
| 4 cm| 3,5 cm
| DRAIN 10000 on: 43 cm off: 22 cm
DRAIN 12000 on: 44 cm off: 23 cm| DRAIN 10000 on: 33 cm off: 25 cm
DRAIN 15000 on: 43 cm off: 24 cm
| 10 m| 10 m

ABOUT THIS HANDBOOK

  • Read this documentation before starting up the machine. This is a precondition for safe working and flawless operation.
  • Observe the safety warnings in this docu-mentation and on the product.
  • This documentation is a permanent integral part of the product described and must be passed on to the new owner if the product is sold.

Explanation of symbols

  • CAUTION!
    Following these safety warnings care-fully can prevent personal injury and/or material damage.

  • ADVICESpecial instructions for greater ease of understanding and improved handling.

PRODUCT DESCRIPTION

This documentation describes various different models of immersion pumps. Identify your model using the identification plate.

Product overview

1 Connection cable with mains plug
2 Carrying handle
3 Float switch cable
4 Pump housing
5 Float switch
6 Suction slots
7 Connection elbow
8 Combination nipple
9 Venting (only Drain 10000/15000 INOX)

Function Drain 10000 / 12000
The immersion pump draws the conveying medium through the suction slots directly and feeds it to the pump outlet at the combination nipple. It is switched on and off using a float switch.

Function Drain 10000 INOX / 15000 INOX
The immersion pump draws the conveying medium through the suction slots directly and feeds it to the pump outlet. It is switched on and off using a float switch. In order to operate properly, the immersion pump must be vented at the venting facility.

Inox stainless steel
Units marked with the designation “INOX” are supplied in stainless steel. The structure and function are unaffected by this.

Designated use
The immersion pump is designed for private use in the house and garden. It must only be operated within the framework of the deployment limitations in accordance with the technical data.
The immersion pump is suitable for:

  • Water removal in the event of a flood
  • Re-pumping and pumping out from vessels (e.g. swimming pools)
  • Water removal from streams and shafts
  • Water removal from drains and trickle shafts.

The immersion pump is only suitable for conveying the following fluids:

  • Clear water, rainwater
  • Chlorine-containing water (e.g. swimming pools)
  • Waste water
  • Dirty water having a max. suspended matter proportion of 5 % and a grain size of max. 30 mm diameter.

Any use not in accordance with this designated use shall be regarded as misuse.

Possible misuse
The immersion pump must not be used continuously. They are not suitable for conveying:

  • Drinking water
  • Salt water
  • Foodstuffs aggressive media, chemicals
  • corrosive, flammable, explosive or fuming fluids
  • fluids that are hotter than 35 °C
  • water containing sand and abrasive fluids.

SCOPE OF SUPPLY
Thermal protection
The equipment is fitted with a thermal protection switch which switches the motor off in the event of overheating. After a cooling-down phase of approx. 15 – 20 minutes the pump switches on automatically.
Operate the unit only if the immersion pump is fully immersed.

SAFETY INSTRUCTIONS

CAUTION!
Danger of injury!
Only use the machine and the extension cable if it is in perfect technical condition! Damaged units must not be used.
Safety and protective devices must not be deactivated!

  • Children, or people who are not familiar with the operating instructions, are not allowed to use the machine.
  • Never lift, transport or suspend the unit using the connection cable.
  • Unilateral modifications or conversions of the unit are prohibited.

Electrical safety

CAUTION!
Danger when touching voltage con-ducting parts!
Disconnect the plug from the mains if the extension cable is damaged or severed! We recommend connecting a RCD (residual current operated device) having a nominal residual current of < 30 mA.

  • The house mains voltage must agree with the details quoted in the technical data, do not use any other supply voltage.
  • The unit must only be operated with an electrical installation in accordance with DIN/VDE 0100, Part 737, 738 and 702 (swimming pools). Protection must be provided by a 10 A line protection switch and a RCCD (residual current operated device) having a nominal residual current of 10/30 mA.
  • Use only extension cables that are suitable for use outdoors – minimum cross-section 1.5 mm2. Cable drums should always be unrolled completely.
  • Damaged or brittle extension cables must not be used.
    • Check the condition of your extension cable each time you start to use the equipment.

ASSEMBLY **

**

Mounting the pressure line see Fig. A and E

  1. Screw the connection elbow (7) into the pump outlet.
  2. Screw the combination nipple (8) into the connection elbow.
  3. Fix a hose to the combination nipple.
    ADVICE The combination nipple can be trim-med to suit the selected hose connection. Use the largest possible hose diameter.

STARTUP

Safety
CAUTION!
Exclude, by suitable means, that, in the event of a fault in the immersion pump, consequential damage is caused by flooding.

  • Make sure that the immersion pump is standing securely or operate the immersion pump suspended from a rope.
  • Make sure there is adequate clearance under the pump.
  • Never allow the immersion pump to run against a closed off pressure line.
  • When using in shafts, make sure the size is adequate.
  • Always cover the shaft with a secure foot-plate.

Switching the pump on see Fig. A – E
CAUTION!
The immersion pump must not draw in any solid bodies. Sand and other abrasive materials in the conveying medium will destroy the immersion pump.

  1. Unwind the connection cable (1) completely.

  2. Make sure that the electrical plug connection is mounted in the area safe from flooding.

  3. Change the terminal position and adjust the switching points of the float switch (5) individually.

  4. Attach the cable on the float switch to the pump housing (4) securely.
    ➯ Recommended cable length on the float switch approx. 120 mm
    ADVICE Use a suitable plate to ensure se-cure mounting of the immersion pump on muddy, sandy or stony ground.

  5. Immerse the immersion pump in the conveying medium slowly. Hold the immersion pump at a slight angle to allow any air to escape.

  6. Vent the immersion pump DRAIN 10000 INOX/15000 INOX at the venting unit (Fig. D)

  7. Insert the mains plug into the plug socket.
    ➯ The immersion pump switches on automatically using the float switch when a specific water level has been reached, and switches off again if the water drops below the switch-off height.

Switching the pump off

  • Remove the mains plug from the plug socket.

MAINTENANCE AND CARE

Cleaning the pump

ADVICE After conveying chlorine-containing swimming pool water or fluids that leave a residue, the pump must be flushed out with clear water.

  • Clean the suction slots on the suction foot if necessary with clear water.

STORAGE
ADVICE In the event of a risk of frost, the system must be drained completely.

DISPOSAL
Do not dispose of old equipment, batteries or accumulators as house hold waste!
Product, packaging, and accessories were made with recyclable materials, and should be disposed of accordingly.

HELP IN CASE OF MALFUNCTIONS

CAUTION!
Disconnect the mains plug before any fault rectification work! Faults in the electrical system must be rectified by a qualified electrician.

Malfunction Possible cause Solution
Motor does not run Impeller blocked Remove dirt in the suction area. Clean

with a suitable tool through the opening at the back of the motor housing.
Thermal protection switch has switched off.| Wait until the thermal protection switch on the immersion pump switches on again. Take note of the maximum temperature of the conveying medium.

Have the immersion pump inspected.

No mains power.| Check the fuses, have the power sup- ply checked by a qualified electrician.
Float switch does not switch off when the water level rises.| Send the immersion pump to an AL- KO service facility.
Pump running but des not feed.| Air in pump housing.| Vent the immersion pump by holding it at an angle.
Blockage on the suction side.| Remove dirt in the suction area.
Pressure line closed off.| Open the pressure lone.
Pressure hose kinked.| Extend the pressure hose.
Feed rate too low| Hose diameter too small.| Use a bigger pressure hose.
Blockage on the suction side.| Remove dirt in the suction area.
Feed head to high.| Observe max. feed head, see technical data!

ADVICE If the faults cannot be rectified, please contact our customer service department.

WARRANTY

If any material or manufacturing defects are found during the statutory customer protection period, we will either repair or replace the equipment, whichever we consider the more appropriate. This statutory period may vary according to the legislation in force in the country where the equipment was purchased.

Our warranty is valid only if:

  • The equipment has been used properly
  • The operating instructions have been followed
  • Genuine replacement parts have been used

The warranty is no longer valid if:

  • The equipment has been tampered with
  • Technical modifications have been made
  • The equipment was not used for its intended purpose

The following are not covered by warranty:

  • Paint damage due to normal wear
  • Wear parts identified by a border [xxx xxx (x)] on the spare parts list
  • Combustion motors (these are covered by a separate warranty from the manufacturer concerned)

The warranty period begins on the purchase by the first end user. Decisive is the date on the receipt. To make a claim under warranty, please take this statement of warranty and proof of purchase to the nearest authorised customer service centre. This warranty does not affect the usual statutory rights of the customer relative to the seller.

EU DECLARATION OF CONFORMITY

We hereby declare that this product, in the version brought into circulation by us, complies with the re-quirements of the harmonised EU guidelines, EU safety standards and the product-specific standards.

Product : Type

Immersion pump, electrical
DRAIN 10000 INOX) DRAIN 12000 DRAIN 15000 INOX

Serial number G3023025

Duly authorised person
Anton Eberle
Ichenhauser Str. 14
D-89359 Kötz

EU guidelines
2006/95/EU
2004/108/EU
2000/14/EU (13)
2011/65/EU
Kötz, 25.05.2012
Antonio De Filippo; Managing Director

Manufacturer
AL-KO Geräte GmbH
Ichenhauser Str. 14
D-89359 Kötz

Harmonised standards
EN 60335-1; VDE 0700-1:2007-02
EN 60335-2-41; VDE 0700-41:2004-12
EN 60335-2-41/A2; VDE 0700-41/A2:2009-02 EN 55014-1; VDE 0875-14-1:2007-06
EN 55014-1/A1; VDE 0875-14-1/A1:2008-12 EN 55014-2; VDE 0875-14-2:2009-06
EN 61000-3-2; VDE 0838-2:2006-10
EN 61000-3-2/A1; VDE 0838-2/A1:2007-05 EN 61000-3-2/A7; VDE0838-2/A7:2007-06
EN 61000-3-2/A4; VDE 0838-2/A4:2007-06 EN 61000-3-3; VDE 0838-3:2009-06

ETK DRAIN 10000
Art.-Nr. 112825

ETK DRAIN 12000
Art.-Nr. 112826

ETK DRAIN 10000 INOX
Art.-Nr. 112827

ETK DRAIN 15000 INOX
Art.-Nr. 112828

AL-KO-Drain-10000-Inox-Submersible-Pump-26

AL-KO Geraete GmbH I Head Quarter J lchenhauser StraBe 14 I 89359 Koetz I Germany
Telefon: {+49)8221/203-0 I Telefax: (+49)8221/203-138 I www.al- ko.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals