TOOLOTS EPS Series Electronic Balance User Manual
- October 30, 2023
- TOOLOTS
Table of Contents
TOOLOTS EPS Series Electronic Balance
EPS Series Electronic Balance
The EPS Series Electronic Balance is a precision weighing instrument designed for laboratory, industrial, and educational use. The balance features RS232C communication capabilities, allowing it to be easily connected to a PC for data transfer and analysis. It includes a variety of setup menus for customizing the weighing units and operating modes to fit your specific needs. The balance also comes equipped with an auto-off feature to conserve battery life when not in use.
Product Usage Instructions
RS232C Communication
To connect the scale to a PC, follow the wiring method below:
- 1 Empty
- 2 RXD
- 3 TXD
- 4 5G
- 6 Empty
- 7 Empty
- 8 Empty
- 9 Empty
The baud rate for communication is set to 9600. The data format output is
+-XXX.XX Unit
Care and Maintenance
To keep the scale operating properly, keep the housing and weighing pan clean and free from foreign material. If necessary, use a cloth dampened with mild detergent to clean. Keep the calibration mass in a safe, dry place. Always unplug the AC adapter when not in use, and remove the batteries from the housing for long-term storage.
Error Codes
The following list describes the various errors that may appear on the display:
- Description
- Setup Menus
Press and hold the MODE key for 3 seconds to access the setup menu. Press the UNIT key to make a selection from OFF (automatic power off), CAL ON (calibration), END (exit menu), and UNIT. Press the TARE key to access a submenu, and exit the menu by pressing TARE when END appears.
Setup Menus
The unit selection submenu permits you to specify which weighing units and
operating modes will be enabled for use during operation.
The following units and modes are available:
Display Indicator | Weighing Units and Modes |
---|---|
g | grams |
oz | ounces |
ozt | troy ounces |
dwt | pennyweight |
lb | pounds |
t | taels (Hong Kong, Singapore, or Taiwan) |
ct | carat |
pc | parts counting |
To set the units and modes:
- Press MODE key for 3 seconds to access the setup menu. The display will show UNIT.
- Press TARE key. The display will show the grams unit indicator (g) along with the current status (ON/OFF).
- Press UNIT to change the status.
- Press TARE to accept the displayed status. The display will show the next unit indicator along with the current status.
- Set each unit or mode ON or OFF as in steps c and d.
- After finishing units setting, press TARE and the balance display UNIT. Press unit key continuously to find the setup menus displayed in a circle. Press TARE when END appears to exit setup
menu.
Taels Selection
If taels are enabled, you will be required to choose one of three different taels: Hong Kong, Singapore, or Taiwan correspondingly as below:
- TAEL 1 = Hong Kong tael
- TAEL 2 = Singapore tael
- TAEL 3 = Taiwan tael
Auto Off
The auto-off feature permits the selection of either OFF, 60 seconds, 120 seconds, or 180 seconds. When this function is selected, the balance will turn off if it is idle for the selected period of time (60, 120, or 180 seconds). This feature is especially useful when the balance is operated from internal batteries.
To view, change, or disable the auto-off feature:
- Press MODE key for 3 seconds to access the setup menu.
- Press UNIT key continuously to find the A. OFF setup submenu.
- Press TARE key to check the current auto-off status.
- Press UNIT to change the status.
- Press TARE key to confirm the setting.
- Releasing the TARE key, A. OFF will be displayed again. Press UNIT to exit.
Description
EPS series portable electronic scales are precision weighing instruments. The portable advanced scale consists of a housing constructed of a material which is impact resistant, a one piece solid-state precision electronic PC board with a 5 digit LCD displayer which is 0.5 inches in height and a strain gauge load cell inside. All portable balances are initially factory set to measure in grams and can be set to other units of measure as desired. Each balance operates through a series of menus that enable precise calibration and the selection of various parameters that enhances operation. A built in lock switch prevents calibration settings from being changed. Power is supplied through an AC adapter or batteries.
Setup menus
Press and hold the “MODE” key for 3 seconds to access the setup menu, continue
to press the “UNIT” key to make selection “A. OFF”(automatic power off), “CAL
ON”(calibration) ,“END”(exit menu) and “UNIT”. In this process, you can press
“TARE” key to access a submenu, and exit the menu by another touch on “TARE”
when “END” appears.
The unit selection submenu permits you to specify which weighing units and
operating modes will be enabled for use during operation. The adjacent table
lists the units and modes available on the EPS series balances. Proceed as
Follows:
-
Press “MODE” key for 3 seconds to access the setup menu, the display will show “UNIT”.
-
Press “TARE” key, the display will show the grams unit indicator (g) along with the current status (ON/OFF).
-
Press “UNIT” to change the status.
-
Press “TARE” to accept the displayed status, when released, the display will show the next unit indicator along with the current status.
-
Set each unit or mode ON or OFF as in steps c and d.
-
After finishing units setting, press “TARE” and the balance display” UNIT”, press the “unit” key continuously to find the setup menus displayed in circle. Press “TARE” when “END” appears to exit setup menu.
Taels selection
If taels are enabled, you will be required to choose one of three different
taels: Hong Kong, Singapore, or Taiwan correspondingly as below:
TAEL 1=Hong Kong tael, TAEL 2=Singapore tael and TAEL 3=Taiwan tael.
Auto off
Auto off permits the selection of either OFF, 60 seconds, 120seconds or 180
seconds. When this function is selected, the balance will turn off if it is
idle for the selected period of time (60, 120 or 180 seconds). This feature is
especially useful when the balance is operated from internal batteries.
View, change or disable the auto off feature
- Press “MODE” key for 3 seconds to access the setup menu.
- Press “UNIT” key continuously to find the “A. OFF” setup submenu.
- Press “TARE” key to check the current auto-off status.
- Press “UNIT” to change the status.
- Press “TARE” key to confirm the setting.
- Releasing the “TARE” key, “A. OFF” will be displayed again. Press “UNIT” key continuously to find that “END” appears, then another
- touch on “TARE” to exit setup.
Calibration
When precise weighing is necessary, please calibrate the scales as follows:
- With no load on the pan, press and hold the “MODE” key for 3 seconds, the scale will display “UNIT” indicating accessing the setup menu.
- Press “UNIT” key twice to access the “CAL ON” submenu.
- Press “TARE” key to confirm. The scale will display “SCALE” or “LINE” that can be shifted by pressing the “UNIT” key. “SCALE” means sensitivity calibration and “LINE” indicates linearity calibration of the scale. Press “TARE” to confirm the desired calibration option.
Sensitivity Calibration
When the display shows “SCALE”, press “TARE” key to find the currently required calibrated mass displayed on the screen. Press “UNIT” key once again shift between the two optional calibrated masses. Pressing “TARE” key to confirm one of the two desired for calibration, zero first flashes on the displayer, then automatically shifts to flashing value of the calibrated mass. Put the corresponding calibrated weight on the pan and wait for a few seconds until the displayer stops flashing and shows the value of the calibrating mass that indicates calibration finishes and normal weighing can be done.
Linearity calibration
When the scale displays “LINE”, press “TARE” key to see the scale flashes.
Wait for a few seconds, the scale flashes half of the value of the full load
specified. Put onto the pan the calibrated mass corresponding to the value
displayed. The scale then flashes the value of the required calibrated mass
for full load a few seconds later. Put on the corresponding weight to wait
till the scale stops flashing and displays the value of the calibrated mass
loaded, thus the calibration finishes, normal weighing can be done.
Remark: Scales are factory calibrated. When linearity calibration is necessary
or a load cell is replaced, please use an accurately calibrated mass to
calibrate the scale.
the calibration finishes, normal weighing can be done.
Remark: Scales are factory calibrated. When linearity calibration is necessary
or a load cell is replaced, please use an accurately calibrated mass to
calibrate the scale.
Backlight
Press “MODE” key to switch on or off the backlight.
RS232C communication
Wiring method
Connect the scale with PC as below:
Baud rate = 9600
Data format output
+(-)XXX.XX Unit < CR >
All segments above belong to ASCⅡ in which the unit can be that set for the
scale.
Demonstrating software of communication
- The super end under Win9x/NT/2000/XP
- The debugging assistant on http://www.gjwtech.com, Self-arranging communication software.
Care and maintenance
To keep the scale operating properly, the housing and weighing pan should be
kept clean and free from foreign material. If necessary, a cloth dampened with
a mild detergent may be used. Keep the calibration mass in a safe dry place.
Always unplug the AC adapter when not in use, and remove the batteries from
the housing for long-term
Error codes
The following list describes the various errors that may appear on the display and the suggested remedies:
Display description:
0. LOAD: This indicates that the weight loaded on the scale exceeds the capacity specified. If this error occurs when the loaded weight is in the range of the capacity of the scale, please re-calibrate the scale with an accurate calibration mass.
Troubleshooting
SYMPTOM | PROBABLE CAUSE | REMEDY |
---|---|---|
No display | Power adapter not ready |
Dead battery
| Check power supply Replace the power
source or batteries
Low battery indicator| Weak battery| Recharge the battery
Incorrect weight reading| Scale is not tared before use Scale not properly
calibrated| With no load on the pan, press “TARE” before weighing Recalibrate
Can not be calibrated
accurately
| Inaccurate weights being used in
calibration
| Use properly calibrated weights
Packing list
An electronic scale, 2. An AC adapter, 3. User’s manual.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>