BLUE JAY BJ193 Series Panel Meter User Manual
- June 10, 2024
- BLUE JAY
Table of Contents
- BLUE JAY BJ193 Series Panel Meter
- Product Information
- Specifications
- Product Usage Instructions
- SUMMARIZE
- SPECIFICATIONS
- INSTALLATION AND START-UP
- Installation
- SCREEN DISPLAY
- OPERATION MODE
- SETUP PROCEDURE
- SAFETY CONSIDERATIONS
- MAINTENANCE
- TECHNICAL SERVICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BLUE JAY BJ193 Series Panel Meter
Product Information
The BJ193-X series Digital Meter is a device used for power quality monitoring, factory automation, and building automation. This series can measure the power parameters in the power grid including current, voltage, frequency, active power, reactive power, apparent power, and power factor. It is designed to replace many traditional analog measurement instruments, improving system accuracy and reliability.
Specifications
- Reference standard: Basic electricity: GB/T13850-1998 (IEC688-1992) Active power : GB/T17215-2002 (IEC61036:2000) Reactive power : GB/T17882-1999 (IEC61268:1995)
- Accuracy standards:
Parameter | Accuracy |
---|---|
Voltage | 0.5%fs |
Current | 0.5%fs |
Active Power | 0.5%fs |
Reactive Power | 0.5%fs |
Apparent Power | 0.5%fs |
Power Factor | 0.5%fs |
Frequency | 0.05%rd |
Input Voltage: Rated 100/220/380V Current: Rated 5A (optional
1A) Frequency: 45-65Hz Notes: accept customized order
Product Usage Instructions
- Before turning on the power supply, ensure that the power supply is within the provisions of the instrument.
- During installation, ensure that the current input terminal is non-open, and voltage input terminals are not short-circuited.
- Strictly prohibit imposing high pressure on the communication terminal (RS232 or RS485).
- Ensure that the instrument wiring is consistent with the internal system settings.
- When communicating with the PC, ensure that the instrument communication parameters are consistent with the PC.
It is important to read this user manual carefully and be able to fully understand the implications and correct guidance of operations in accordance with the user manual. This will help you make better use of the BJ193 series Digital Meter and help yo solve various problems at the scene. Please save this document for future reference.
Tel: +0086-023-67628702
Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China
Read me
When you use BJ193-X series Digital Meter, be sure to carefully read this user
manual, and be able to fully understand the implications, the correct guidance
of operations in accordance with user manual, which will help you make better
use BJ193 series Digital Meter, and help to solve the various problems at the
scene.
- Before the meter turning on the power supply, be sure that the power supply within the provisions of the instrument;
- When installation, the current input terminal must non-open, voltage input terminals must Non-short circuit;
- Communication terminal (RS232 or RS485) is strictly prohibited to impose high pressure;
- Be sure the instrument wiring consistent with the internal system settings;
- When communicating with the PC, instrument communication parameters must be consistent with the PC.
Please read carefully before using this user manual
Please save this document
SUMMARIZE
BJ193-X series Digital Meter is used for power quality monitoring, factory
automation and building automation.
These series can measure the power parameters in power grid:
- Current,
- Voltage,
- Frequency,
- Active power
- Reactive power,
- Apparent power,
- Power factor,
It can replace many of a traditional analog measurement instruments, improve system accuracy and reliability.
SPECIFICATIONS
-
Reference standard:
Basic electricity: GB/T13850-1998 (IEC688-1992)
Active power : GB/T17215-2002 (IEC61036:2000)
Reactive power : GB/T17882-1999 (IEC61268:1995) -
Accuracy standards
Parameter| Accuracy
---|---
Voltage Current Active Power
Reactive Power Apparent power Power Factor Frequency
| 0.5%fs 0.5%fs 0.5%fs 0.5%fs 0.5%fs 0.5%fs 0.05%rd
3. – Input
Voltage: Rated 100/ 220/ 380V
Current: Rated 5A (optional 1A)
Frequency: 45-65Hz
Notes: accept customized order
-
Load
Voltage: <0.5VA / phase (rated 220V)
Current: <0.5VA / phase (rated 5A) -
Overload
Current: 1.2 times rated continuous; 10 seconds for 10 times the rated.
Voltage: 1.2 times the rated continuous; 10 seconds for 800V. -
Dielectric strength
IEC 688 / IEC 255-3 (1989)
2kV AC RMS 1 minute, between input / output / case / power supply. -
EMC Test
| standard| Test voltage
---|---|---
Electrostatic discharge immunity test:| IEC-61000-4-2
level 4
| ****
8Kv
Electrical fast transient burst immunity test| IEC61000-4-4
level 3
| ****
Input 1kV; Power supply 2kV
Surge (Shock) immunity test
| IEC61000-4-5
level 4
| ****
common mode test voltage 4kV
-
Work environment
Temperature: -20℃~ +60℃
Humidity: RH 20%~95%(No condensation) -
Protection
Panel: IP40 -
Storage Conditions
Temperature:-25℃~+70℃
Humidity: RH 20%~95% -
Power Supply
AC /DC 80-270V
Maximum power consumption 3W
INSTALLATION AND START-UP
warning
The manual you hold in your hands contains information and warnings that
the user should respect in order to guarantee a proper operation of all the
instrument functions and keep its safety conditions. The instrument must not
be powered and used until its definitive assembly on the cabinet’s door.
Whether the instrument is not used as manufacturer’s specifications, the protection of the instrument can be damaged. When any protection failure is suspected to exist (for example, it presents external visible damages),the instrument must be immediately powered off. In this case contact a qualified service representative.
Installation
Mounting
Instrument is to be mounted on panel. All connections keep inside the cabinet.
Note that with the instrument powered on, the terminals could be dangerous to
touching and cover opening actions or elements removal may allow accessing
dangerous parts. Therefore, the instrument must not be used until this is
completely installed.
Auxiliary power:
BJ193X Series Digital Meter with universal (AC / DC) power input, if not for a
special statement, we provide the 220VAC/DC or 110VAC/DC power interface for
standard products Instruments limit work power supply : AC / DC :80-270V,
please ensure that the auxiliary power can match for BJ193-X series meter to
prevent damage to the product.
- A. Suggest install 1A fuse in the fire line side.
- B. For the areas with poor power quality, suggest install lightning surge suppressor and rapid burst suppressor to prevent lightning strikes
Connection terminal and drawing (details please see label on the rear part)
Three phase 4 wire voltage
Terminal description
- 11. Voltage A-phase input
- 12. Voltage B-phase input
- 13. Voltage C-phase input
- 14. Neutral Voltage input
Three phase 3 wire voltage
Terminal description
- 11. Voltage A-phase input
- 12. Voltage B-phase input
- 13. Voltage C-phase input
- 14. COM for B-phase input
Single phase or DC voltage
Terminal description
- 11. Voltage phase input
- 14. Neutral Voltage input
Three phase current
Terminal description
- 4. Current A-phase – S1 input
- 5. Current A-phase – S2 input
- 6. Current B-phase – S1 input
- 7. Current B-phase – S2 input
- 8. Current C-phase – S1 input
- 9. Current C-phase – S2 input
Single phase or DC current
Terminal description
- 4. CT secondary side – S1 input
- 5. CT secondary side – S2 input
Other terminals (optional function) Note: This connection drawing is for reference only, the actual connecting terminal please refer to the label on the rear part.
IMPORTANT REMARK!
If power = -0.01 is shown for any of the phases and voltage and current are
not zero for this phase, check out following points:
- Assure that A,B,C phases coincide in voltage and current.
- Correct polarity? Reverse the current transformer placed at this phase.
SCREEN DISPLAY
Note:
- Single phase meter only have one line LED screen
- 48*48 meter panel like following panel design. Without “right” button, detail operation please see chapter 5.
OPERATION MODE
The instrument has three line displays. Every led will be on according to the
parameter presently shown in screen.
When the 193-X is powered up, all the LED indicator will on, and meter start
self- test, after some seconds, the meter is ready for operation and shows one
of the available screens.
-
Parameters on display can be switched by pressing key on screen at any moment
-
When the key is pressed, the screen CURRENT values of each phase are now showing.
-
In setting menu, pressing key can move the setting cursor to left;
-
Pressing can enter the number 0 ~ 9.
-
Pressing it can open the setting menu and return to previous menu.
In setting menu for change number 0~9 (only for 48*48 size meter) -
Pressing this key you can exit it with saving any modification that you might have done, in menu operation press “Enter” key, and user can go to the next menu.
Note :
Press in normal standby status, and the meter will show different data in main
screen: In the menu set mode, when changes the parameter and exit setting, the
meter will ask to
“SAVE”, press exit without saving press save and exit.
SETUP PROCEDURE
The SETUP procedure of the BJ193-X is performed by means of several SETUP options. Once into the SETUP, use the keyboard to select different options and enter required variables:
- Password enter
- Input signal selection
- Communication preferences
Single phase menu:
Three phase menu:
Note:
The procedure above is for reference, not all series have the step 3
(communication preference), AO menu for D series have this function, bUS menu
for K series, please contact the Technical Service.
SAFETY CONSIDERATIONS
All installation specification described at the previous chapters named : INSTALLATION AND STARTUP, OPERATION MODE and SPECIFICATIONS. Note that with the instrument powered on, the terminals could be dangerous to touching and cover opening actions or elements removal may allow accessing dangerous parts. This instrument is factory-shipped at proper operation condition.
MAINTENANCE
The 193-X does not require any special maintenance. No adjustment, maintenance
or repairing action should be done when the instrument open and powered on,
should those actions are essential, high-qualified operators must perform
them.
Before any adjustment, replacement, maintenance or repairing operation is
carried out, the instrument must be disconnected from any power supply source.
When any protection failure is suspected to exist, the instrument must be
immediately put our of service. The instrument’s design allows a quick
replacement in case of any failure.
TECHNICAL SERVICE
For any inquiry about the instrument performance or whether any failure
happens, contact to Blue Jay’s technical service.
Blue Jay – After-sales service
E-mail : tech@cqbluejay.com
Tel: +0086-023-67628702 Email:tech@cqbluejay.com
www.cqbluejay.com
Add: 1802,Building 2,No.88,Jianxin East Road,Chongqing,400020,China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>