Westinghouse WGEN5300SC 5300 Watt Electric Start Portable Generator User Guide
- June 4, 2024
- Westinghouse
Table of Contents
WGEN5300SC 5300 Watt Electric Start Portable
Generator
User Guide
BEFORE STARTING
-
Install feet to frame. a. Tip the generator onto the muffler side.
b. Install the mounting feet to the frame using M8 flange bolts. -
Install wheels. a. Install the axle pin, wheel, and washer through the axle bracket on the frame.
b. Install the hairpin cotter through the axle pin to lock it in place. -
Add engine oil a. Remove oil fill plug/dipstick.
b. Using the supplied 4-cycle engine oil and funnel, slowly add engine oil to the engine until full.
c. Replace oil fill plug/dipstick. -
Add unleaded gasoline to the gas tank. a. Unscrew the gas cap on top of the tank and insert a clean funnel into the tank.
b. Slowly add gasoline into the fuel tank. The gasoline level should NOT be higher than the filler neck.
c. Secure gas cap.
STARTING PROCEDURE
-
Make sure the generator is OUTSIDE in a well-ventilated dry area and FAR AWAY from any doors, windows, or vents.
-
Check fuel and oil levels
-
Make sure nothing is plugged into power outlets.
-
Connect the battery.
-
Make sure the circuit breakers are properly set to operate.
-
Move the fuel valve to the ON position.
-
Move the choke lever to the ON position. If the engine is warm turn the lever to the OFF position.
-
Choose starting method:
a. Electric Start: Push and hold the engine control switch in the START position. Once the engine starts, release. b. Manual Start: Switch the engine control switch to the RUN position. Firmly grasp and pull the recoil handle slowly until you feel increased resistance. At this point, apply a rapid pull while pulling up and slightly away from the generator. -
After the engine starts, gradually move the choke lever to the OFF position.
-
Plug-in electronic devices.
MAINTENANCE SCHEDULE
Following the maintenance schedule is important to keep the generator in good
operating condition. The following is a summary of maintenance items by
periodic maintenance intervals.
Refer to the Maintenance section in the Owners Manual to find out how to
properly perform maintenance.
Maintenance Item| Before Every Use| After First 25 Hours or
First Month of Use| After 50 Hours of Use or Every 6 Months| After
100 Hours of Use or Every 6 Months| After 300 Hours of Use or Every
Year
---|---|---|---|---|---
Engine Oil| Check Level| Change1| Change| –| –
Air Filter| –| –| Clean2| –| Replace
Spark Plug| –| –| –| Check/Clean| Replace
Spark Arrestor| –| –| –| Check/Clean| –
| | –| –| Clean| –
Valve Clearance| –| –| –| Inspect/Adjust3| –
¹ Change oil every month when operating under heavy loads or in high
temperatures.
² Clean more often under dirty or dusty conditions
³ Recommended service by authorized Westinghouse dealer.
ENGINE OIL
Only
use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL. Synthetic oil is
an acceptable substitute for conventional oil.
PREVENT CARBON MONOXIDE (CO) POISONING
- Use outdoors far from occupied buildings and the exhaust pointed away from personnel and buildings
- Point exhaust away all homes and occupied spaces
- Install CO alarms in your home
DANGER
Using a generator indoors
CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide.
This is a poison you cannot see or smell.
|
NEVER use it inside a home or garage,
EVEN IF doors and windows are open.| Only use OUTSIDE and far away
from windows, doors, and vents.
Avoid other generator hazards.
READ THE MANUAL BEFORE USE.
Questions?
Call 855.944.3571 or
email service@wpowereq.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>