This product is a stud detector that helps locate studs, metal, and AC cables behind walls. It has several indicators to help determine the location of these materials.

Product Getting started

  1. Open the battery compartment cover (8) and insert a battery according to the correct polarity. Close the cover.
  2. Calibration: Place the device flat against any surface that is free of studs, metal, and AC cables. Press and hold the Power/scan button (4) until the red (1) and green (7) indicators flash and a beeping sound is heard. The calibration is complete when the green light turns on. Do not move the device until the calibration is complete. Wait for 3 seconds after the calibration is complete before using the device. Calibration must be done every time the device has been turned on for use.

Product Usage

If you are receiving erratic scanning results, it may be a result of humidity, moisture within the wall cavity or drywall, or recently applied paint or wallpaper that isn’t fully dried.

Low battery indicator

  • If the battery status indicator (7) starts flashing, immediately change the battery.

Product Specifications

  • Max. detection depth
  • Sound alert
  • Light alert
  • Operating temperature range
  • Power supply
  • Dimensions
  • Weight

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Product Care and maintenance

Battery safety instructions: Follow battery manufacturer’s instructions for charging, usage, and disposal. Do not expose the battery to fire or high temperatures. Remove the battery if the product will not be used for an extended period of time.

Product Warranty

Levenhuk International Lifetime Warranty: This product is warranted to be free of defects in materials and workmanship for the lifetime of the product. Visit www.levenhuk.bg/garantsiya for more information.

Overview

levenhuk-Ermenrich-Ping-SA20-Stud-Detector-fig-1

  1. Center indicator
  2. Signal strength indicator
  3. Stud direction indicator (on the left)
  4. Power/scan button
  5. Signal strength indicator II
  6. Stud direction indicator (on the right)
  7. Battery status indicator
  8. Battery compartment cover

Getting started

Open the battery compartment cover (8) and insert a battery according to the correct polarity. Close the cover.

Calibration

Place the device flat against any surface that is free of studs, metal and AC cables. Press and hold the Power/scan button (4) until the red (1) and green (7) indicators flash and a beeping sound is heard. The calibration is complete when the green light turns on. Do not move the device until the calibration is complete. Wait for 3 seconds after the calibration is complete before using the device.

Attention: Calibration must be done every time the device has been turned on for use.

Usage

Complete the calibration and place the device flat against the examined surface. Press and hold the Power/scan button (4) and slowly move the detector across the surface in the direction you want to scan. When the device detects the edge of a stud, signal strength indicators (2, 5) light up. Continue sliding it in the same direction until the signal strength indicators go down. Start slowly moving the device in the opposite direction until the signal strength indicators (2, 5) light up again. When the device detects the center of a stud, the center indicator (1) lights up. If you are receiving erratic scanning results, it may be a result of humidity, moisture within the wall cavity or drywall, or recently applied paint or wallpaper that isn’t fully dried.

Low battery indicator

  • If the battery status indicator (7) starts flashing, immediately change the battery.

Specifications

  • Max. detection depth: wood/metal studs: 19mm (¾”)
  • Sound alert: +
  • Light alert: +
  • Operating temperature range: 0…+40°C (operating), −10…+50°C (storage) / +32…+104°F (operating), +14…+122°F (storage)
  • Power supply: 1pc 9V battery
  • Dimensions: 146x63x35mm (5.7×2.5×1.4in)
  • Weight: 90g (0.2lb)

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and maintenance

Do not exclusively rely on the detector to locate items behind scanned surfaces. Do not assume that there is no live cabling inside a wall. Always disconnect the power, gas, and water before scanning. Calibrate the device regularly. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Store the device in a dry cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately. Keep away from children.

Battery safety instructions

Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.

Warranty

Levenhuk International Lifetime Warranty

All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions are met.

For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.

Contacts

Levenhuk®, Ermenrich® are registered trademarks of Levenhuk, Inc.

© 2006–2023 Levenhuk, Inc. All rights reserved.
www.levenhuk.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals